Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
•
2W Output Power
•
Ultra-Miniature SIP Case
•
1,000 VDC Isolation
•
>2 MHour MTBF
•
18 Standard Models
•
Industry Standard Pin-Out
Input
Parameter
Conditions
5 VDC Input
Input Voltage Range
12 VDC Input
24 VDC Input
48 VDC Input
Reverse Polarity Input Current
Input Filter
Internal Capacitor
Conditions
For Vin Change of 1%
Min.
Typ.
±1.2
100
120
±0.01
Momentary (0.5 Sec.)
Conditions
60 Seconds
1,000 VDC
100 kHz, 1V
Min.
1,000
1,000
60
125
Conditions
Ambient
Case
-55
Free Air Convection
RH, Non-condensing
95
%
Min.
-40
Typ.
+25
Max.
+85
+90
+125
Typ.
Max.
Units
VDC
MΩ
pF
kHz
Units
ºC
ºC
ºC
±0.02
Max.
±3.0
Units
%
%
mV P - P
%
%/ºC
Min.
4.5
10.8
21.6
44.0
Typ.
5.0
12.0
24.0
48.0
Max.
5.5
13.2
26.4
52.0
0.3
A
Units
VDC
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation (Note 1)
Ripple & Noise (20 MHz) (Note 2)
Output Power Protection
Temperature Coefficient
Output Short Circuit
See Model Selection Guide
RoHS Compliant
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
MicroPower Direct
Physical
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Weight
Case Size
Case Material
0.46 x 0.29 x 0.40 Inches (11.68 x 7.5 x 10.2 mm)
Non-Conductive Black Plastic (UL94-V0)
0.06 Oz (1.8g)
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
2.0
Min.
-0.7
-0.7
-0.7
-0.7
Typ.
Max.
Units
MHours
Units
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Typ.
Max.
9.0
18.0
30.0
55.0
260
650
ºC
mW
Input Voltage Surge (1 Sec)
VDC
Lead Temperature
Internal Power Dissipation
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
E201
E202
E203
E204
E205
E211
E212
E213
E214
E215
E222
E223
E224
E225
E232
E233
E234
E235
Input
Voltage (VDC)
Nominal
Range
5
4.5 - 5.5
5
5
5
5
12
12
12
12
12
24
24
24
24
48
48
48
48
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
44.0 - 52.0
44.0 - 52.0
44.0 - 52.0
44.0 - 52.0
Output
Load
Current (mA)
Voltage Current
Current Regulation
Full-Load No-Load (VDC) (mA, Max) (mA, Min) (% Max)
372
38
3.3
400.0
40.0
12
533
500
500
500
150
200
211
199
208
107
102
104
102
53
52
53
52
38
38
38
38
30
30
30
25
25
12
12
12
12
6
6
6
6
5.0
9.0
12.0
15.0
3.3
5.0
9.0
12.0
15.0
5.0
9.0
12.0
15.0
5.0
9.0
12.0
15.0
400.0
222.0
167.0
133.0
400.0
400.0
222.0
167.0
133.0
400.0
222.0
167.0
133.0
400.0
222.0
167.0
133.0
40.0
22.0
16.0
13.0
40.0
40.0
22.0
16.0
13.0
40.0
22.0
16.0
13.0
40.0
22.0
16.0
13.0
12
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Efficiency
(%, Typ)
71
75
79
80
80
73
77
79
84
80
78
82
80
82
78
80
78
80
Fuse Rating
Slow-Blow
(mA)
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
200
200
200
200
100
100
100
100
Notes:
1. Output load regulation is specified for a load change of 20% to 100%.
2. When measuring output ripple, it is recommended that an external 0.33
µF
ceramic capacitor be placed from the +Vout pin to the -Vout pin.
3. Operation at no-load will not damage these units. However, they may
not meet all specifications.
4. The 5V, 12V and 24V input units do not require external components to
operate, but the use of a low ESR capacitor (approximately 10
µF,
ESR
<1.0Ω at 100 kHz) mounted close to the converter input pins is recom-
mended.
For 48 VDC input units, an input capacitor should always be used. Depen-
dent upon the application, a value between 4.7
µF
and 47
µF
should be
sufficient.
5. Out put capacitive load capability of these units is 33
µF
max. Exceeding
this may cause start up problems.
5. It is recommended that a fuse be used on the input of a power supply
for protection. See the table above for the correct rating.
Derating Curve
Pin Connections
Pin
1
2
3
4
Description
-Vin
+Vin
-Vout
+Vout
Mechanical Dimensions
Notes:
•
All dimensions are typical in inches (mm)
•
Tolerance x.xx = ±0.01 (±0.25)
•
Pin 1 is marked by a “dot” or indentation
on the side of the unit
MicroPower Direct
www.micropowerdirect.com
•
292 Page Street Ste D Stoughton, MA 02072
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com