Cylindrical Proximity Sensor
A new series of easy–to–use models for
standard– and double–distance
Stainless steel and brass housing
Two housing length for each type
Pre–wired and Plug–in connector types
Short–circuit protection and reverse pola-
rity protection
E2EL
Ordering Information
Cable types
Brass housing
Diameter
∅6,5
Length
30 mm
32 mm
45 mm
47 mm
M8
30 mm
32 mm
45 mm
47 mm
M12
41 mm
Mounting
Shielded
Non–shielded
Shielded
Non–shielded
Shielded
Non–shielded
Shielded
Non–shielded
Shielded
Shielded
Non–shielded
53 mm
Shielded
Shielded
Non–shielded
M18
40 mm
Shielded
Shielded
Non–shielded
73 mm
Shielded
Shielded
Non–shielded
M30
40 mm
80 mm
Shielded
Non–shielded
Shielded
Non–shielded
Sensing
Distance
1,5 mm
2,0 mm
1,5 mm
2,0 mm
1,5 mm
2,0 mm
1,5 mm
2,0 mm
2,0 mm
4,0 mm
4,0 mm
2,0 mm
4,0 mm
4,0 mm
5,0 mm
8,0 mm
8,0 mm
5,0 mm
8,0 mm
8,0 mm
10,0 mm
15,0 mm
10,0 mm
15,0 mm
Output
NPN / NO
E2EL–C1R5E1 2M
E2EL–C2ME1 2M
E2EL–C1R5E1–L 2M
E2EL–C2ME1–L 2M
E2EL–X1R5E1 2M
E2EL–X2ME1 2M
E2EL–X1R5E1–L 2M
E2EL–X2ME1–L 2M
E2EL–X2E1 2M
E2EL–X4E1–D 2M
E2EL–X4ME1 2M
E2EL–X2E1–L 2M
E2EL–X4E1–DL 2M
E2EL–X4ME1–L 2M
E2EL–X5E1 2M
E2EL–X8E1–D 2M
E2EL–X8ME1 2M
E2EL–X5E1–L 2M
E2EL–X8E1–DL 2M
E2EL–X8ME1–L 2M
E2EL–X10E1 2M
E2EL–X15ME1 2M
E2EL–X10E1–L 2M
E2EL–X15ME1–L 2M
NPN / NC
E2EL–C1R5E2 2M
E2EL–C2ME2 2M
E2EL–C1R5E2–L 2M
E2EL–C2ME2–L 2M
E2EL–X1R5E2 2M
E2EL–X2ME2 2M
E2EL–X1R5E2–L 2M
E2EL–X2ME2–L 2M
E2EL–X2E2 2M
E2EL–X4E2–D 2M
E2EL–X4ME2 2M
E2EL–X2E2–L 2M
E2EL–X4E2–DL 2M
E2EL–X4ME2–L 2M
E2EL–X5E2 2M
E2EL–X8E2–D 2M
E2EL–X8ME2 2M
E2EL–X5E2–L 2M
E2EL–X8E2–DL 2M
E2EL–X8ME2–L 2M
E2EL–X10E2 2M
E2EL–X15ME2 2M
E2EL–X10E2–L 2M
E2EL–X15ME2–L 2M
PNP / NO
E2EL–C1R5F1 2M
E2EL–C2MF1 2M
E2EL–C1R5F1–L 2M
E2EL–C2MF1–L 2M
E2EL–X1R5F1 2M
E2EL–X2MF1 2M
E2EL–X1R5F1–L 2M
E2EL–X2MF1–L 2M
E2EL–X2F1 2M
E2EL–X4F1–D 2M
E2EL–X4MF1 2M
E2EL–X2F1–L 2M
E2EL–X4F1–DL 2M
E2EL–X4MF1–L 2M
E2EL–X5F1 2M
E2EL–X8F1–D 2M
E2EL–X8MF1 2M
E2EL–X5F1–L 2M
E2EL–X8F1–DL 2M
E2EL–X8MF1–L 2M
E2EL–X10F1 2M
E2EL–X15MF1 2M
E2EL–X10F1–L 2M
E2EL–X15MF1–L 2M
PNP / NC
E2EL–C1R5F2 2M
E2EL–C2MF2 2M
E2EL–C1R5F2–L 2M
E2EL–C2MF2–L 2M
E2EL–X1R5F2 2M
E2EL–X2MF2 2M
E2EL–X1R5F2–L 2M
E2EL–X2MF2–L 2M
E2EL–X2F2 2M
E2EL–X4F2–D 2M
E2EL–X4MF2 2M
E2EL–X2F2–L 2M
E2EL–X4F2–DL 2M
E2EL–X4MF2–L 2M
E2EL–X5F2 2M
E2EL–X8F2–D 2M
E2EL–X8MF2 2M
E2EL–X5F2–L 2M
E2EL–X8F2–DL 2M
E2EL–X8MF2–L 2M
E2EL–X10F2 2M
E2EL–X15MF2 2M
E2EL–X10F2–L 2M
E2EL–X15MF2–L 2M
1
E2EL
Stainless steel housing
Diameter
∅6,5
M8
M12
M18
Length
30 mm
45 mm
30 mm
45 mm
41 mm
53 mm
40 mm
73 mm
Mounting
Shielded
Shielded
Shielded
Shielded
Shielded
Shielded
Shielded
Shielded
Sensing
Distance
2,0 mm
2,0 mm
2,0 mm
2,0 mm
4,0 mm
4,0 mm
8,0 mm
8,0 mm
Output
NPN / NO
E2EL–C2E1–DS 2M
E2EL–C2E1–DSL 2M
E2EL–X2E1–DS 2M
E2EL–X2E1–DSL 2M
E2EL–X4E1–DS 2M
E2EL–X4E1–DSL 2M
E2EL–X8E1–DS 2M
E2EL–X8E1–DSL 2M
NPN / NC
E2EL–C2E2–DS 2M
E2EL–C2E2–DSL 2M
E2EL–X2E2–DS 2M
E2EL–X2E2–DSL 2M
E2EL–X4E2–DS 2M
E2EL–X4E2–DSL 2M
E2EL–X8E2–DS 2M
E2EL–X8E2–DSL 2M
PNP / NO
E2EL–C2F1–DS 2M
E2EL–C2F1–DSL 2M
E2EL–X2F1–DS 2M
E2EL–X2F1–DSL 2M
E2EL–X4F1–DS 2M
E2EL–X4F1–DSL 2M
E2EL–X8F1–DS 2M
E2EL–X8F1–DSL 2M
E2EL
PNP / NC
E2EL–C2F2–DS 2M
E2EL–C2F2–DSL 2M
E2EL–X2F2–DS 2M
E2EL–X2F2–DSL 2M
E2EL–X4F2–DS 2M
E2EL–X4F2–DSL 2M
E2EL–X8F2–DS 2M
E2EL–X8F2–DSL 2M
Plug types
Brass housing
Diameter /
Connection
∅6,5
/
Plug M8
Length
45 mm
47 mm
54 mm
56 mm
M8 /
Plug M8
45 mm
47 mm
54 mm
56 mm
M8 /
Plug M12
44 mm
46 mm
60 mm
62 mm
M12 /
Plug M12
60 mm
49 mm
Mounting
Shielded
Non–shielded
Shielded
Non–shielded
Shielded
Non–shielded
Shielded
Non–shielded
Shielded
Non–shielded
Shielded
Non–shielded
Shielded
Shielded
Non–shielded
Shielded
Shielded
Non–shielded
M18 /
Plug M12
80 mm
53 mm
Shielded
Shielded
Non–shielded
Shielded
Shielded
Non–shielded
M30 /
Plug M12
80 mm
55 mm
Shielded
Non–shielded
Shielded
Non–shielded
Sensing
Distance
1,5 mm
2,0 mm
1,5 mm
2,0 mm
1,5 mm
2,0 mm
1,5 mm
2,0 mm
1,5 mm
2,0 mm
1,5 mm
2,0 mm
2,0 mm
4,0 mm
4,0 mm
2,0 mm
4,0 mm
4,0 mm
5,0 mm
8,0 mm
8,0 mm
5,0 mm
8,0 mm
8,0 mm
10,0 mm
15,0 mm
10,0 mm
15,0 mm
Output
NPN / NO
E2EL–C1R5E1–M3
E2EL–C2ME1–M3
E2EL–C1R5E1–M3L
E2EL–C2ME1–M3L
E2EL–X1R5E1–M3
E2EL–X2ME1–M3
E2EL–X1R5E1–M3L
E2EL–X2ME1–M3L
E2EL–X1R5E1–M1
E2EL–X2ME1–M1
E2EL–X1R5E1–M1L
E2EL–X2ME1–M1L
E2EL–X2E1–M1
E2EL–X4E1–DM1
E2EL–X4ME1–M1
E2EL–X2E1–M1L
E2EL–X4E1–DM1L
E2EL–X4ME1–M1L
E2EL–X5E1–M1
E2EL–X8E1–DM1
E2EL–X8ME1–M1
E2EL–X5E1–M1L
E2EL–X8E1–DM1L
E2EL–X8ME1–M1L
E2EL–X10E1–M1
E2EL–X15ME1–M1
E2EL–X10E1–M1L
E2EL–X15ME1–M1L
NPN / NC
E2EL–C1R5E2–M3
E2EL–C2ME2–M3
E2EL–C1R5E2–M3L
E2EL–C2ME2–M3L
E2EL–X1R5E2–M3
E2EL–X2ME2–M3
E2EL–X1R5E2–M3L
E2EL–X2ME2–M3L
E2EL–X1R5E2–M1
E2EL–X2ME2–M1
E2EL–X1R5E2–M1L
E2EL–X2ME2–M1L
E2EL–X2E2–M1
E2EL–X4E2–DM1
E2EL–X4ME2–M1
E2EL–X2E2–M1L
E2EL–X4E2–DM1L
E2EL–X4ME2–M1L
E2EL–X5E2–M1
E2EL–X8E2–DM1
E2EL–X8ME2–M1
E2EL–X5E2–M1L
E2EL–X8E2–DM1L
E2EL–X8ME2–M1L
E2EL–X10E2–M1
E2EL–X15ME2–M1
E2EL–X10E2–M1L
E2EL–X15ME2–M1L
PNP / NO
E2EL–C1R5F1–M3
E2EL–C2MF1–M3
E2EL–C1R5F1–M3L
E2EL–C2MF1–M3L
E2EL–X1R5F1–M3
E2EL–X2MF1–M3
E2EL–X1R5F1–M3L
E2EL–X2MF1–M3L
E2EL–X1R5F1–M1
E2EL–X2MF1–M1
E2EL–X1R5F1–M1L
E2EL–X2MF1–M1L
E2EL–X2F1–M1
E2EL–X4F1–DM1
E2EL–X4MF1–M1
E2EL–X2F1–M1L
E2EL–X4F1–DM1L
E2EL–X4MF1–M1L
E2EL–X5F1–M1
E2EL–X8F1–DM1
E2EL–X8MF1–M1
E2EL–X5F1–M1L
E2EL–X8F1–DM1L
E2EL–X8MF1–M1L
E2EL–X10F1–M1
E2EL–X15MF1–M1
E2EL–X10F1–M1L
E2EL–X15MF1–M1L
PNP / NC
E2EL–C1R5F2–M3
E2EL–C2MF2–M3
E2EL–C1R5F2–M3L
E2EL–C2MF2–M3L
E2EL–X1R5F2–M3
E2EL–X2MF2–M3
E2EL–X1R5F2–M3L
E2EL–X2MF2–M3L
E2EL–X1R5F2–M1
E2EL–X2MF2–M1
E2EL–X1R5F2–M1L
E2EL–X2MF2–M1L
E2EL–X2F2–M1
E2EL–X4F2–DM1
E2EL–X4MF2–M1
E2EL–X2F2–M1L
E2EL–X4F2–DM1L
E2EL–X4MF2–M1L
E2EL–X5F2–M1
E2EL–X8F2–DM1
E2EL–X8MF2–M1
E2EL–X5F2–M1L
E2EL–X8F2–DM1L
E2EL–X8MF2–M1L
E2EL–X10F2–M1
E2EL–X15MF2–M1
E2EL–X10F2–M1L
E2EL–X15MF2–M1L
Stainless steel housing
Diameter /
Connection
M8 /Plug
M8
M12 /
Plug M12
M18 /
Plug M12
Length
54 mm
49 mm
60 mm
53 mm
80 mm
Mounting
Shielded
Shielded
Shielded
Shielded
Shielded
Sensing
Distance
2,0 mm
4,0 mm
4,0 mm
8,0 mm
8,0 mm
Output
NPN / NO
E2EL–X2E1–DM3SL
E2EL–X4E1–DM1S
E2EL–X4E1–DM1SL
E2EL–X8E1–DM1S
E2EL–X8E1–DM1SL
NPN / NC
E2EL–X2E2–DM3SL
E2EL–X4E2–DM1S
E2EL–X4E2–DM1SL
E2EL–X8E2–DM1S
E2EL–X8E2–DM1SL
PNP / NO
E2EL–X2F1–DM3SL
E2EL–X4F1–DM1S
E2EL–X4F1–DM1SL
E2EL–X8F1–DM1S
E2EL–X8F1–DM1SL
PNP / NC
E2EL–X2F2–DM3SL
E2EL–X4F2–DM1S
E2EL–X4F2–DM1SL
E2EL–X8F2–DM1S
E2EL–X8F2–DM1SL
2
E2EL
E2EL
Specifications
Brass type
Type
Operating voltage
Rated supply voltage
Current consumption
Sensing object
Mounting ((s)hielded,
(n)on–shielded) (see note 1)
Operating distance in mm
Tolerance of operating distance
Standard target size in mm
(L x W x H in mm, FE 37)
Differential travel
Max. response frequency in kHz
Control output
Type
∅6,5
10 to 35 VDC
24 VDC
max. 15 mA at 24 VDC
Ferrous metals
s
1,5
±10%
6,5x6,5x1
8x8x1
12x12x1
18x18x1
24x24x1
30x30x1
45x45x1
n
2,0
s
1,5
n
2,0
s
2,0
s
4,0
n
4,0
s
5,0
s
8,0
n
8,0
s
10,0
n
15,0
M8
M12
M18
M30
1 % ... 15 % of operating distance
5,0
5,0
2,0
0,6
1,0
0,5
0,3
0,5
0,25
0,15
E2EL–... E1 type: NPN–NO
E2 type: NPN–NC
F1 type: PNP–NO
F2 type: PNP–NC
200 mA
2,5 VDC (at 200mA load current and with 2 m cable)
Reverse polarity, output short–circuit
Operating indicator (yellow LED)
Operating: –25° to 70°C
35 to 95 % RH
±
10 % max. of Sn at 23°C in temperature range of –25° to 70°C
1.500 VAC, 50/60 Hz for 1 min. between current carry parts and case
EN 60947–5–2
Destruction: 10 to 70 Hz, 1,5 mm double amplitude for 1 hour each in X, Y and Z directions
Destruction: 300 m/s@ (approx. 30 G) for 6 times each in X, Y and Z directions
IP 67 (EN 60947–1)
Max–Load
Max–on–state
Voltage drop
Circuit protection
Indicator
Ambient temperature
Humidity
Influence of temperature
Dielectric strength
Electromagnetic compatibility EMC
Vibration resistance
Shock
resistance
Enclosure
rating
Connection
(see note 2)
Pre–wired
Connector
Weight in g
Pre–wired
Connector
Material
Case
Sensing face
Note:
long
short
long
short
2 m PVC–cable, 3 x
0,14 mm@
M8 plug
45
43
10
8
Brass
PBTP
M8 plug
M12 plug
50
48
15
13
2 m PVC–cable, 3 x 0,25 mm
2
M12 plug
75
70
25
20
115
100
60
50
2m PVC–cable, 3 x
0,5 mm
2
260
200
155
110
1. For detailed mounting instruction please refer to page 11.
2. PUR cable and different length on request.
3
E2EL
Stainless steel type
Type
Operating voltage
Rated supply voltage
Current consumption
Mounting (see note 1)
Sensing object
Operating distance in mm
Tolerance of operating distance
Standard target size
(L x W x H in mm, FE 37)
Differential
travel
Max. response frequency in kHz
Control output
Type
24 VDC
max. 15 mA at 24 VDC
Shielded
Ferrous metals
2,0
±10%
6,5x6,5x1
8x8x1
12x12x1
24x24x1
2,0
4,0
8,0
∅6,5
10 to 35 VDC
M8
M12
M18
E2EL
1 % ... 15 % of operating distance
4,0
4,0
0,6
0,25
E2EL–... E1 type: NPN–NO
E2 type: NPN–NC
F1 type: PNP–NO
F2 type: PNP–NC
200 mA
2,5 VDC (at 200mA load current and with 2 m cable)
Reverse polarity, output short–circuit
Operating indicator (yellow LED)
Operating: –25° to 70°C
35 to 95 % RH
±
10 % max. of Sn at 23°C in temperature range of –25° to 70°C
1.500 VAC, 50/60 Hz for 1 min. between current carry parts and case
EN 60947–5–2
Destruction: 10 to 70 Hz, 1,5 mm double amplitude for 1 hour each in X, Y and Z directions
Destruction: 300 m/s@ (approx. 30 G) for 6 times each in X, Y and Z directions
IP 67 (EN 60947–1)
Max–Load
Max–on–state
Voltage drop
Circuit protection
Indicator
Ambient temperature
Humidity
Influence of temperature
Dielectric strength
Electromagnetic compatibility EMC
Vibration resistance
Shock resistance
Enclosure
rating
Connection
(see note 2)
Weight in g
Pre–wired
Connector
Pre–wired
Connector
Material
Case
Sensing face
Note:
long
short
long
short
2 m PVC–cable, 3 x 0,14 mm@
–
45
43
–
–
PBTP
M8 plug
50
48
10
–
2 m PVC–cable, 3 x 0,25 mm
2
M12 plug
75
70
25
20
120
105
65
55
stainless steel 1.4305 / AISI 303
1. For detailed mounting instruction please refer to page 11.
2. PUR cable and different length on request.
4
E2EL
E2EL
Engineering Data
Standardized characteristic for lateral approach
1,2
axial distance related to effective operating distance
standard target
axial
approach
1
’switch–on’ curve
0,8
’
switch–off’ curve
lateral approach
0,6
on
0,4
off
0,2
0
–1
–0,8
–0,6
–0,4
–0,2
0
0,2
0,4
0,6
0,8
1
lateral distance related to radius of ’active surface’ (r/r
act
)
Output Circuit Diagram and Timing Chart
E2EL–XjEj
NPN Output
Brown 1
E2EL-XjFj
PNP Output
Brown 1
4,7 kΩ
Main
circuit
Load
Main
circuit
4,7 kΩ
Blue 3
Black 4 (or 2)
Black 4 (or 2)
Load
0V
Blue 3
E2EL–XjEj
NPN Output
NO
Sensing object
Yellow indicator
Control output
Yes
No
Lit
Not lit
ON
OFF
NC
E2EL–XjFj
PNP Output
Sensing object
Yellow indicator
Control output
Yes
No
Lit
Not lit
ON
OFF
NO
NC
5