LAB
1
2
SEME
IP1R17A
IP3R17A
IP1R17A
IP3R17A
3 AMP
FIXED NEGATIVE
VOLTAGE REGULATORS
3
Pin 1 – Ground
Pin 2 – V
OUT
Case – V
IN
FEATURES
• 0.01%/V LINE REGULATION
• 0.5% LOAD REGULATION
• ±1% OUTPUT TOLERANCE
(–A VERSIONS)
• AVAILABLE IN –5V, –12V AND –15V OPTIONS
• COMPLETE SERIES OF PROTECTIONS:
• CURRENT LIMITING
• THERMAL SHUTDOWN
• SOA CONTROL
K Package – TO–3
1 2 3
1
2
3
Pin 1
Pin 2
Pin 3
Case
–
–
–
–
Ground
V
IN
V
OUT
V
IN
Pin 1
Pin 2
Pin 3
Case
–
–
–
–
Ground
V
IN
V
OUT
V
IN
G Package – TO–257
T Package – TO–220
Order Information
Part
Number
IP1R17Axx–zz
IP1R17xx–zz
IP3R17Azz–xx
IP3R17zz–xx
K–Pack
(TO–3)
G–Pack
T–Pack
(TO–257) (TO–220)
Temp.
Range
-55 to +150°C
”
0 to +125°C
”
Note:
xx = Voltage Code
(05, 12, 15)
eg.
IP1R17AK–05
zz = Package Code
(G, K, T)
IP3R17G–12
ABSOLUTE MAXIMUM RATINGS
(Tcase = 25°C unless otherwise stated)
V
I
P
D
T
J
T
STG
T
L
DC Input Voltage
Power Dissipation
Operating Junction Temperature Range
Storage Temperature Range
Lead Temperature (Soldering, 10 sec)
35V
Internally limited
See Table Above
–65°C to +150°C
300°C
Semelab plc.
Telephone (01455) 556565. Telex: 341927. Fax (01455) 552612.
Prelim. 4/96
LAB
ELECTRICAL CHARACTERISTICS
Parameter
Test Conditions
I
O
= -5mA to -3A
P
≤
P
MAX
V
IN
= -8V to -20V
-5.15
3
6
5
10
-4.85
15
30
25
50
5
10
5
2.2
60
80
0.002
-6.5
-4.5
-4
-1
40
1.5
3
2.5
4
0.01
-6.5
3
60
2.2
80
-5.25
6
12
10
20
2
SEME
IP1R17A
IP3R17A
IP1R17A
IP3R17A
(T
C
= 25°C unless otherwise stated)
IP1R17A–05
IP3R17A–05
Min. Typ. Max.
-5.05
-5
-4.95
IP1R17–05
IP3R17–05
Min. Typ. Max. Units
-5.15
-5
-4.85
-4.75
30
60
50
100
5
10
mA
5
3
V
dB
0.02
%/W
A
A
µV
2.5
4
°C/W
V
V
V
O
Output Voltage
T
J
= Over Temp. Range
1
∆V
O
∆V
I
∆V
O
∆I
O
I
Q
Line Regulation
Load Regulation
Quiescent Current
Quiescent Current
Change
V
IN
= -7.5V to -35V
I
O
= -5mA
3
T
J
= Over Temp. Range
1
3
mV
mV
mA
I
O
= -5mA to -3A
I
O
= -5mA
T
J
= Over Temp. Range
1
T
J
= Over Temp. Range
1
I
O
= -5mA to -3A
∆I
Q
T
J
= Over Temp. Range
1
I
O
= -5mA
I
O
= -3A
I
O
= -1A
t
p
= 20ms
V
IN
= -10V
V
IN
= -10V
V
IN
= -35V
K Package
G, T Package
V
IN
= -7.5V to -35V
∆V
OUT
= 100mV
f = 120Hz
∆P
= P
MAX
T
J
= Over Temp. Range
1
T
J
= Over Temp. Range
1
V
D
Dropout Voltage
Ripple Rejection
Thermal Regulation
T
J
= Over Temp. Range
1
T
J
= Over Temp. Range
1
0.002
-4.5
-4
-1
40
1.5
3
I
PEAK
Peak Output Current
I
SC
e
n
R
θJC
Short Circuit Current
Output Noise Voltage f = 10Hz to 100kHz
Thermal Resistance
Junction to Case
Notes
1) Applies over full temperature range:–
T
J
= –55 to +150°C for IP1R17A–05 / IP1R17–05
T
J
=
0 to +125°C for IP3R17A–05 / IP3R17–05
All other specifications apply at T
C
= 25°C unless otherwise stated.
2) Test conditions unless otherwise stated:–
V
IN
= -10V , I
OUT
= -1.5A .
Although Power Dissipation is internally limited, these specifications apply for Power Dissipation up to 30W for the TO–3
Package, and 20W for the TO–220 and TO–257 Packages.
3) Load and Line regulation are electrically independent and are measured using pulse techniques at low duty cycle in order to
maintain constant junction temperature. To determine the effects on the output voltage due to device heating, refer to thermal
regulation specification.
Semelab plc.
Telephone (01455) 556565. Telex: 341927. Fax (01455) 552612.
Prelim. 4/96
LAB
ELECTRICAL CHARACTERISTICS
Parameter
Test Conditions
I
O
= -5mA to -3A
P
≤
P
MAX
V
IN
= -15V to -27V
-12.36
5
10
10
20
-11.64 -12.60
30
60
60
120
5
10
5
2.2
52
72
0.002
-6.5
-4.5
-2.5
-1
75
1.5
3
2.5
4
0.01
-6.5
3
52
2.2
72
10
20
20
40
2
SEME
IP1R17A
IP3R17A
IP1R17A
IP3R17A
(T
J
= 25°C unless otherwise stated)
IP1R17A–12
IP3R17A–12
Min. Typ. Max.
-12.12
-12
IP1R17–12
IP3R17–12
Min. Typ. Max. Units
-12
-11.64
-11.40
60
120
120
240
5
10
mA
5
3
V
dB
0.02
%/W
A
A
µV
2.5
4
°C/W
V
V
-11.88 -12.36
V
O
Output Voltage
T
J
= Over Temp. Range
1
∆V
O
∆V
I
∆V
O
∆I
O
I
Q
Line Regulation
Load Regulation
Quiescent Current
Quiescent Current
Change
V
IN
= -14.5V to -35V
I
O
= -5mA
3
T
J
= Over Temp. Range
1
3
mV
mV
mA
I
O
= -5mA to -3A
I
O
= -5mA
T
J
= Over Temp. Range
1
T
J
= Over Temp. Range
1
I
O
= -5mA to -3A
∆I
Q
T
J
= Over Temp. Range
1
I
O
= -5mA
I
O
= -3A
I
O
= -1A
t
p
= 20ms
V
IN
= -17V
V
IN
= -17V
V
IN
= -35V
K Package
G, T Package
V
IN
= -14.5V to -35V
∆V
OUT
= 250mV
f = 120Hz
∆P
= P
MAX
T
J
= Over Temp. Range
1
T
J
= Over Temp. Range
1
V
D
Dropout Voltage
Ripple Rejection
Thermal Regulation
T
J
= Over Temp. Range
1
T
J
= Over Temp. Range
1
0.002
-4.5
-2.5
-1
75
1.5
3
I
PEAK
Peak Output Current
I
SC
e
n
R
θJC
Short Circuit Current
Output Noise Voltage f = 10Hz to 100kHz
Thermal Resistance
Junction to Case
Notes
1) Applies over full temperature range:–
T
J
= –55 to +150°C for IP1R17A–12 / IP1R17–12
T
J
=
0 to +125°C for IP3R17A–12 / IP3R17–12
All other specifications apply at T
C
= 25°C unless otherwise stated.
2) Test conditions unless otherwise stated:–
V
IN
= -17V , I
OUT
= -1.5A .
Although Power Dissipation is internally limited, these specifications apply for Power Dissipation up to 30W for the TO–3
Package, and 20W for the TO–220 and TO–257 Packages.
3) Load and Line regulation are electrically independent and are measured using pulse techniques at low duty cycle in order to
maintain constant junction temperature. To determine the effects on the output voltage due to device heating, refer to thermal
regulation specification.
Semelab plc.
Telephone (01455) 556565. Telex: 341927. Fax (01455) 552612.
Prelim. 4/96
LAB
ELECTRICAL CHARACTERISTICS
Parameter
Test Conditions
I
O
= -5mA to -3A
P
OUT
≤
P
MAX
V
IN
= -18V to -30V
-15.45
8
16
16
32
-14.55 -15.75
40
80
80
160
5
10
5
2.2
50
70
0.002
-6.5
-4.5
-2.3
-1
90
1.5
3
2.5
4
0.01
-6.5
3
50
2.2
70
16
32
32
64
2
SEME
IP1R17A
IP3R17A
IP1R17A
IP3R17A
(T
J
= 25°C unless otherwise stated)
IP1R17A–15
IP3R17A–15
Min. Typ. Max.
-15.15
-15
IP1R17–15
IP3R17–15
Min. Typ. Max. Units
-15
-14.55
-14.25
80
160
160
320
5
10
mA
5
3
V
dB
0.02
%/W
A
A
µV
2.5
4
°C/W
V
V
-14.85 -15.45
V
O
Output Voltage
T
J
= Over Temp. Range
1
∆V
O
∆V
I
∆V
O
∆I
O
I
Q
Line Regulation
Load Regulation
Quiescent Current
Quiescent Current
Change
V
IN
= -17.5V to -35V
I
O
= -5mA
3
T
J
= Over Temp. Range
1
3
mV
mV
mA
I
O
= -5mA to -3A
I
O
= -5mA
T
J
= Over Temp. Range
1
T
J
= Over Temp. Range
1
I
O
= -5mA to -3A
∆I
Q
T
J
= Over Temp. Range
1
I
O
= -5mA
I
O
= -3A
I
O
= -1A
t
p
= 20ms
V
IN
= -20V
V
IN
= -20V
V
IN
= -35V
K Package
G, T Package
V
IN
= -17.5V to -35V
∆V
OUT
= 300mV
f = 120Hz
∆P
= P
MAX
T
J
= Over Temp. Range
1
T
J
= Over Temp. Range
1
V
D
Dropout Voltage
Ripple Rejection
Thermal Regulation
T
J
= Over Temp. Range
1
T
J
= Over Temp. Range
1
0.002
-4.5
-2.3
-1
90
1.5
3
I
PEAK
Peak Output Current
I
SC
e
n
R
θJC
Short Circuit Current
Output Noise Voltage f = 10Hz to 100kHz
Thermal Resistance
Junction to Case
Notes
1) Applies over full temperature range:–
T
J
= –55 to +150°C for IP1R17A–15 / IP1R17–15
T
J
=
0 to +125°C for IP3R17A–15 / IP3R17–15
All other specifications apply at T
C
= 25°C unless otherwise stated.
2) Test conditions unless otherwise stated:–
V
IN
= -20V , I
OUT
= -1.5A .
Although Power Dissipation is internally limited, these specifications apply for Power Dissipation up to 30W for the TO–3
Package, and 20W for the TO–220 and TO–257 Packages.
3) Load and Line regulation are electrically independent and are measured using pulse techniques at low duty cycle in order to
maintain constant junction temperature. To determine the effects on the output voltage due to device heating, refer to thermal
regulation specification.
Semelab plc.
Telephone (01455) 556565. Telex: 341927. Fax (01455) 552612.
Prelim. 4/96