Optoway
SPB-7610WG
1
***********************************************************************************************************************************************************************
SPB-7610WG / SPB-7610BWG / SPB-7610AWG
(SC BIDI SFP)
(RoHS Compliant)
SPB-7610LWG / SPB-7610BLWG / SPB-7610ALWG
(LC BIDI SFP)
1310 nm TX / 1550 nm RX , 3.3V / 1250 Mbps
Digital Diagnostic
Single-Fiber SFP Transceiver
FEATURES
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
**********************************************************************************************************************************************************************
DESCRIPTION
1-Fiber Bi-Directional SFP Optical Transceiver
Compliant with IEEE 802.3ah-2004 1000BASE-BX
Simplex
SC
Connector:
SPB-7610WG
Simplex
LC
Connector:
SPB-7610LWG
SFF-8472 Digital Diagnostic Function
1310 nm LD Transmitter
1550 nm Receiver
Distance Up to 10 km
AC/AC Coupling according to MSA
Single +3.3 V Power Supply
RoHS Compliant
0 to 70
o
C Operating: SPB-7610WG
-10 to 85
o
C Operating: SPB-7610BWG
-40 to 85
o
C Operating: SPB-7610AWG
Class 1 Laser International Safety Standard IEC 60825
Compliant
The SPB-7610WG series is small form factor pluggable
module for Gigabit Ethernet 1000BASE-BX and Fibre
Channel single fiber communications by using 1310 nm
transmitter and 1550 nm receiver. It is with the SFP 20-pin
connector to allow hot plug capability. Digital diagnostic
functions are available via an I
2
C. The transmitter section
uses a multiple quantum well 1310 nm laser and is a class
1 laser compliant according to International Safety Standard
IEC 60825. The receiver section uses an integrated 1550 nm
detector preamplifier (IDP) mounted in an optical header
and a limiting post-amplifier IC.
LASER SAFETY
This single mode transceiver is a Class 1 laser product. It
complies with IEC 60825 and FDA 21 CFR 1040.10 and
1040.11. The transceiver must be operated within the
specified temperature and voltage limits. The optical ports of
the module shall be terminated with an optical connector or
with a dust plug.
APPLICATIONS
l
WDM Gigabit Ethernet Links
l
SONET/SDH Equipment Interconnect
l
Fibre Channel Links
ORDER INFORMATION
P/No.
SPB-7610WG
SPB-7610BWG
SPB-7610AWG
SPB-7610LWG
SPB-7610BLWG
SPB-7610ALWG
Bit Rate
(Gb/s)
1.25
1.25
1.25
1.25
1.25
1.25
Distance
(km)
10
10
10
10
10
10
TX
(nm)
1310
1310
1310
1310
1310
1310
RX
(nm)
1550
1550
1550
1550
1550
1550
Package
SC SFP with DMI
SC SFP with DMI
SC SFP with DMI
LC SFP with DMI
LC SFP with DMI
LC SFP with DMI
Temp TX Power
(
o
C)
(dBm)
0 to 70
-3 to -9
-10 to 85 -3 to -9
-40 to 85 -3 to -9
0 to 70
-3 to -9
-10 to 85 -3 to -9
-40 to 85 -3 to -9
RX Sens.
(dBm)
-20
-20
-20
-20
-20
-20
RoHS
Compliant
Yes
Yes
Yes
Yes
Yes
Yes
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC.
No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
Fax: 886-3-5979737
E-mail: sales@optoway.com.tw http: // www.optoway.com.tw
1/1/2008
V3.0
Optoway
Absolute Maximum Ratings
Parameter
Storage Temperature
Operating Case Temperature
Symbol
Tstg
Topr
Min
-40
0
-10
-40
0
0
GND
0
Max
85
70
85
85
85
3.6
Vcc
30
Units
o
C
o
C
SPB-7610WG
Notes
SPB-7610WG
SPB-7610BWG
SPB-7610AWG
Non condensing
2
***********************************************************************************************************************************************************************
Relative Humidity
Power Supply Voltage
Input Voltage
Output Current
RH
Vcc
---
Iout
%
V
V
mA
Recommended Operating Conditions
Parameter
Power Supply Voltage
Power Supply Current
Operating Case Temperature
Symbol
Vcc
I
CC (TX+RX)
Topr
Min
3.1
0
-10
-40
1250
Typ
3.3
200
Max
3.5
300
70
85
85
1300
Units / Notes
V
mA
o
C / SPB-7610WG
o
C / SPB-7610BWG
o
C / SPB-7610AWG
Mb/s
Data Rate
Transmitter Specifications (0
o
C < Topr < 70
o
C, 3.1V < Vcc < 3. 5V)
Parameter
Symbol
Min
Typ
Max
-3
1360
2.5
Units
dBm
nm
nm
dB
ns
ns
dB/Hz
ns
µA
µA
V
V
V
µs
ms
V
V
Notes
1
RMS (σ)
Optical
Optical Transmit Power
Po
-9
Output Center Wavelength
1260
λ
Output Spectrum Width
σ
λ
Extinction Ratio
E
R
9
Output Eye
Compliant with IEEE 802.3z
Optical Rise Time
t
r
Optical Fall Time
t
f
Relative Intensity Noise
RIN
Total Jitter
TJ
Electrical
Data Input Current
–
Low
I
IL
-350
Data Input Current
–
High
I
IH
Differential Input Voltage
V
IH
- V
IL
0.5
TX Disable Input Voltage
–
Low
T
DIS, L
0
TX Disable Input Voltage
–
High
T
DIS, H
2.0
TX Disable Assert Time
T
ASSERT
TX Disable Deassert Time
T
DEASSERT
TX Fault Output Voltage -- Low
T
FaultL
0
TX Fault Output Voltage -- High
T
FaultH
2.0
1310
0.26
0.26
-120
0.227
20% to 80% Values
20% to 80% Values
2
350
2.4
0.5
Vcc
10
1
0.5
Vcc+0.3
Peak-to-Peak
3
3
4
4
Notes: 1. Output power is power coupled into a 9/125
µm
single mode fiber.
2. Measured with a 2
7
-1 PRBS.
3. There is an internal 4.7K to 10K ohm pull-up resistor to VccTX.
4. Open collector compatible, 4.7K to 10K ohm pull-up to Vcc (Host Supply Voltage).
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC.
No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
Fax: 886-3-5979737
E-mail: sales@optoway.com.tw http: // www.optoway.com.tw
1/1/2008
V3.0
Optoway
Receiver Specifications (0
o
C < Topr < 70
o
C, 3.1 V < Vcc < 3. 5V)
Parameter
Optical
Sensitivity
Maximum Input Power
Signal Detect -- Asserted
Signal Detect -- Deasserted
Signal detect -- Hysteresis
Wavelength of Operation
Optical Return Loss
Electrical
Differential Output Voltage
Output LOS Voltage -- Low
Output LOS Voltage
–
High
Signal Detect Assert Time
Signal Detect Deassert Time
Symbol
---
Pin
Pa
Pd
Min
---
-3
---
-31
1.0
1480
14
0.6
0
2.0
Typ
---
---
---
---
---
Max
-20
---
-20
---
1580
Units
dBm
dBm
dBm
dBm
dB
nm
dB
V
V
V
µs
µs
SPB-7610WG
Notes
5
Transition: low to high
Transition: high to low
6
3
***********************************************************************************************************************************************************************
ORL
V
OH
–
V
OL
V
OL
V
OH
AS
MAX
ANS
MAX
2.0
0.5
Vcc+0.3
100
300
7
7
OFF to ON
ON to OFF
Notes: 5. Minimum sensitivity and saturation levels at BER 1E-12 for a 2
7
-1 PRBS.
6. At least 30 dB optical isolation for the wavelength 1260 to 1360 nm.
7. Open collector compatible, 4.7K to 10K ohm pull-up to Vcc (Host Supply Voltage).
RECOMMENDED CIRCUIT SCHEMATIC
VeeT
Tx_DISABLE
T
x_FAULT
(1,17,20)
3
2
4.7K to 10KΩ
TD +
18
Z=50Ω
TD -
19
Z=50Ω
VccT
16
10nF
1μH
Vcc 3.3V
10μF
10nF
1μH
VccR
15
10nF
10μF
10μF
TD -
TD +
Tx_DISABLE
Tx_FAULT
LD
Driver
100Ω
SerDes
IC
Protocol
IC
RD -
12
Z=50Ω
100Ω
RD -
POST
Amp
RD +
13
Z=50Ω
4.7K to 10KΩ
RD +
depending on SERDES
LOSS OF SINGAL
LOS
VeeR
MOD_DEF(0)
8
(9,10,11,14)
6
5
4
4.7K to 10KΩ
Vcc 3.3V
4.7K to 10KΩ
MODULE DETECT
SCL
SDA
4.7K to 10KΩ
EEPROM
MOD_DEF(1)
MOD_DEF(2)
SFP module
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC.
No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
Fax: 886-3-5979737
E-mail: sales@optoway.com.tw http: // www.optoway.com.tw
1/1/2008
V3.0
Optoway
CONNECTION DIAGRAM
SPB-7610WG
4
***********************************************************************************************************************************************************************
PIN
1
2
3
4
5
6
7
8
9
10
Signal Name
TX GND
TX Fault
TX Disable
MOD-DFE2
MOD-DEF1
MOD-DEF0
N/C
LOS
RX GND
RX GND
Description
Transmitter Ground
Transmitter Fault Indication
Transmitter Disable (Module disables
on high or open)
Modulation Definition 2
–
Two wires
serial ID Interface
Modulation Definition 1
–
Two wires
serial ID Interface
Modulation Definition 0
–
Ground in
Module
Not Connected
Loss of Signal
Receiver Ground
Receiver Ground
PIN
11
12
13
14
15
16
17
18
19
20
Signal Name
Description
RX GND
Receiver Ground
RX DATA OUT- Inverse Receiver Data Out
RX DATA OUT+ Receiver Data Out
RX GND
Vcc RX
Vcc TX
TX GND
TX DATA IN+
TX DATA IN-
TX GND
Receiver Ground
Receiver Power
–
3.3V±5%
Transmitter Power
–
3.3V±5%
Transmitter Ground
Transmitter Data In
Inverse Transmitter Data In
Transmitter Ground
Module Definition
Module Definition
4
MOD-DEF2
PIN 4
SDA
MOD-DEF1
PIN 5
SCL
MOD-DEF0
PIN 6
LV-TTL Low
Interpretation by Host
Serial module definition
protocol
Module Definition 4 specifies a serial definition protocol. For this definition, upon power up, MOD-DEF(1:2) appear as no connector
(NC) and MOD-DEF(0) is TTL LOW. When the host system detects this condition, it activates the serial protocol. The protocol uses the
2-wire serial CMOS E
2
PROM protocol of the ATMEL AT24C01A/02/04 family of components.
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC.
No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
Fax: 886-3-5979737
E-mail: sales@optoway.com.tw http: // www.optoway.com.tw
1/1/2008
V3.0
Optoway
PACKAGE DIAGRAM
Units in mm
A) SC SFP
SPB-7610WG
5
***********************************************************************************************************************************************************************
A) LC SFP
Note: Specifications subject to change without notice.
**********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC.
No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
Fax: 886-3-5979737
E-mail: sales@optoway.com.tw http: // www.optoway.com.tw
1/1/2008
V3.0