EEWORLDEEWORLDEEWORLD

Part Number

Search

HMI100-Q050IIE

Description
UNIVERSAL INPUT AC-DC MEDICAL APPLICATION OPEN FRAME SINGLE & MULTI-OUTPUT 100 WATTS INTERNAL SWITCHING POWER SUPPLIES
File Size95KB,3 Pages
ManufacturerHitron
Websitehttp://www.hitron-e.com/
Download Datasheet View All

HMI100-Q050IIE Overview

UNIVERSAL INPUT AC-DC MEDICAL APPLICATION OPEN FRAME SINGLE & MULTI-OUTPUT 100 WATTS INTERNAL SWITCHING POWER SUPPLIES

H HiTRON
2007/07/27
UNIVERSAL INPUT AC-DC MEDICAL APPLICATION OPEN FRAME
SINGLE & MULTI-OUTPUT 100 WATTS INTERNAL SWITCHING
POWER SUPPLIES HMI100 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES
COMPACT 4.5”x 2.5”x1.2” PCB
FORMAT
MEET MEDICAL STANDARD EN 60601-1/
UL 60601-1
EMI MEET EN 55011 & FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage:
90-264Vac.
Input Connector:
V-M connector.
Input Frequency:
47-63Hz.
Inrush Current:
Typ. 9.68Arms @230Vac.
Input Current:
Typ. 1.8A@115Vac, 0.9A @230Vac.
Dielectric Withstand:
Meet IEC 60601-1.
EMI:
Meet EN55011 & CISPR Class B.
Hold-up Time:
Typ. 12.8mS @115Vac, 76mS @ 230Vac.
Earth Leakage:
Less than 0.189mA @230Vac.
OUTPUT SPECIFICATION
Output Voltage:
See Ratings Chart.
Output Current:
See Ratings Chart.
Output Connector:
V-M connector.
Output Wattage:
Typ. 100 watts.
Line Regulation:
Typ. ±0.5%.
Load Regulation:
Main VO1 typ ±1%.
Aux. VO2 typ. ±1%.
Aux. VO3 typ. ±5%.
Aux. VO4 typ. ±5%.
Noise & Ripple:
Typ. 1.0% peak to peak.
OVP:
Built-in at main output (Latch).
Adjustability:
Available at VO1 and VO2.
Overload Protection (OLP):
Fully protected against outputs overload and short circuit.
Typ. OLP set at 110-150% of rating output power.
Consult the factory for OLP setting.
Operating Temperature:
0 to +50 °C under forced air flow
for full load.(Various with output voltage).
Storage Temperature:
-20 to +85°C.
Temperature Coefficient:
Typ. 0.05%/°C.
Cooling:
Recommended 24CFM cooling fan for
full rating load.
Power Density:
7.4 Watts / Cubic Inch.
Construction:
4.5”x2.5“x1.2” PCB format.
GENERAL SPECIFICATION
Efficiency:
Typ. 74-80%(Various with output voltage).
Switching Frequency:
68 KHz.
Circuit Topology:
Single-Forward circuit.
Multiple-Fixed freq. flyback circuit.
Transient Response:
Output voltage returns in less than
14-44mS following a 25% load change.
Safety Standard:
Meet Medical standards UL 60601-1/
EN 60601-1 Class I.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
For the details of safety approval, please consult the factory.

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号