COAXIAL HIGH POWER LIMITER
Frequency Range (min)
Peak Input Power (max)
CW Input Power (max)
CW Flat Leakage (max)
Insertion Loss (max)
VSWR (max)
1 – 2000
1000
60
14
0.3
1.25:1
MHz
W
W
dBm
dB
ratio
NOTES:
Model is rated for 60W CW and is also available in a 100W CW version. See part number ordering information.
Insertion loss is slightly higher for the high power version.
Power handling is linearly derated from full power at 25˚C to zero power at +150˚C.
This model requires DC blocks for proper operation
ENVIRONMENTAL SPECIFICATIONS:
MIL-E-5400, MIL-STD-202, MIL-E-16400
Operating Temp: -55°C to +125°C
Storage Temp: -65°C to +150°C
Humidity: MIL-STD-202F, M103, Cond B
Altitude: MIL-STD-202F, M105, Cond B
Thermal Shock: MIL-STD-202F, M107, Cond A
Temperature Cycle: MIL-STD-202F, M105C, Cond D
SCREENING:
Internal Visual per MIL-STD-883, Method 2017
Temperature Cycle: -65°C to +100°C, 10 cycles
OPTIONAL HIGH-REL SCREENING (Ref MIL-PRF-38534):
Stabilization Bake per MIL-STD-883, Method 1008
Temperature Cycle per MIL-STD-883, Method 1010
Constant Acceleration per MIL-STD-883, Method 2001
Burn-in per MIL-STD-883, Method 1015
External Visual per MIL-STD-883, Method 2009
STANDARD CASE STYLE C46
(Optional Case Styles – C24, C25, C88, C89)
PART NUMBER ORDERING INFORMATION:
•
•
•
•
Add desired case style suffix: “C46” (Ex: ACLM-4874C46)
Add “R” suffix: Reverse Connector Configuration (Ex: ACLM-4874C25R) (SMA Female Input/SMA Male Output)
Add “H” suffix: High power handling version: (Ex: ACLM-4874HC25R)
Add “-RC” suffix: RoHS-compliant (Ex: ACLM-4874HC25-RC)
0109