EEWORLDEEWORLDEEWORLD

Part Number

Search

6GL5B-NBL3

Description
Toggle Switch, DPDT, Momentary, Quick Connect Terminal, Paddle Type Actuator, Panel Mount-threaded,
CategoryMechanical and electronic products    switch   
File Size116KB,1 Pages
ManufacturerCarling Technologies
Environmental Compliance  
Download Datasheet Parametric View All

6GL5B-NBL3 Overview

Toggle Switch, DPDT, Momentary, Quick Connect Terminal, Paddle Type Actuator, Panel Mount-threaded,

6GL5B-NBL3 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typePADDLE TYPE
body width19.05 mm
body height19.76 mm
Body length or diameter33.22 mm
Contact (AC) maximum rated R load15A@125VAC
Maximum contact current (AC)15 A
Maximum contact voltage (AC)125 V
Electrical life25000 Cycle(s)
Installation featuresPANEL MOUNT-THREADED
Maximum operating temperature85 °C
Minimum operating temperature
surface mountNO
Switch actionMOMENTARY
switch functionDPDT
Switch typeTOGGLE SWITCH
Termination typeQUICK CONNECT
Base Number Matches1
Carling
Technologies
G-Series Toggle Switches
G-Series Toggle Switches
General purpose workhorses with options tailored to meet
most any need. Ratings to 20A 277VAC, international
approvals, various actuator, bushing, termination, and cir-
cuit choices allow this toggle switch to easily integrate
into a variety of different applications. The G-Series has a
storied history in the Marine, Food Service, Generator,
Industrial Control, and Office Automation markets and is
appropriate for usage in low voltage DC applications as
well.
.687[17.44]
15/32-32UNS-2A
THREAD
.330[8.38]
.187[4.74]
.465[11.81]
.778[19.76]
SOLDER LUG
.125[3.18] DIA
Dielectric Strength
UL/CSA:
1000V - live to dead
metal parts & opposite polarity
VDE:
4000V - live to dead metal
parts; 1250V - opposite polarity &
across open contacts
Electrical Life
50,000 cycles- maintained
25,000 cycles- momentary
Mechanical Life
100,000 cycles
Operating Temperature
32°F to 185°F (0° to 85°C)
.055[1.40] DIA
.075[1.91] DIA
.437[11.09]
.394[10.00]
.250[6.35]
.250 TAB (Q.C.)
.187[4.74]
.187 TAB (Q.C.)
TERMINAL TYPE
.422[10.72]
1.308[33.22]
.750[19.05]
#6-32NC-2
THREAD
.370[9.39]
.500[12.70]
.286[7.26]
SCREW
(ASSEMBLED)
.490[22.86]
.500[12.70] DIA
.062[1.57]
.500[12.70] DIA
.500[12.70] DIA
.125[3.17] DIA
WITH LOCKING RING
WIRE LEAD
6.000[152.40]
.141[3.58]
.187[4.75]
.350[8.89]
PRINTED
CIRCUIT
.376[9.55]
.187[4.75]
.778[19.76]
KEYWAY
.072[1.82]
X
.038[.965] DP
.075[1.905]
IEC APPROVED CONSTRUCTION
.750[19.05]
MOUNTING HOLE
.038[9.65]
WITH KEYWAY
2GM51
-
73
1
Base Part Number
2
Actuator Style
1 BASE PART NUMBER: SERIES/POLES/CIRCUITRY/RATING/TERMINATION
3
Single Pole in Double Pole base
Double Pole
10A 250VAC, 15A 125VAC, 3/4 HP 125-250VAC
solder lug .250 tab
screw term.
solder lug .250 tab
screw term.
2GA50
2GA51
2GA54
ON-NONE-OFF
2GK50
2GK51
2GK54
6GA5A
6GA5B
6GA5E
(ON)-NONE-OFF
6GK5A
6GK5B
6GK5E
6GA5L
6GA5M
6GA5S
ON-NONE-(OFF)
6GK5L
6GK5M
6GK5S
2GB50
2GB51
2GB54
ON-NONE-ON
2GL50
2GL51
2GL54
ON-NONE-(ON)
6GL5A
6GL5B
6GL5E
6GB5A
6GB5B
6GB5E
2GC50
2GC51
2GC54
ON-OFF-ON
2GM50
2GM51
2GM54
6GC5A
6GC5B
6GC5E
ON-OFF-(ON)
6GM5A
6GM5B
6GM5E
6GC5L
6GC5M
6GC5S
(ON-OFF-(ON)
6GM5L
6GM5M
6GM5S
10A 250VAC, 15A 125VAC, 12 (6)A 250VAC T85/55 ENEC/VDE Approved
1
2GA90
2GA91
-
ON-NONE-OFF
2GK90
2GK91
2GB90
2GB91
-
ON-NONE-ON
2GL90
2GL91
2GC90
2GC91
-
ON-OFF-ON
2GM90
2GM91
Additional ratings up to 20A 125-277VAC, 1 1/2 HP 125VAC, 2HP 250 VAC and special circuits
available. Consult factory for specifics.
2 ACTUATOR STYLE
4
unsealed
73
BAT
5
PADDLE
NBL3
D-3B-B
BAT
2
-
PADDLE
2
NOTES
1
2
3
4
5
()
sealed
78
NBL8
-
D-4B-B
toggle length
0.687
0.687
0.687
0.687
bushing length
0.465
0.465
0.379
0.379
Not available with 73 or NBL3 style toggles, T55 with 78 and NBL8 style toggles.
All nylon bushing and toggle.
Consult factory for .187 tab, wire lead and combination screw/tab/solder lug termination callouts.
Additional actuator options available. Consult factory.
Nylon toggle with black ebanol plated bushing.
Indicates momentary function.
26
www.carlingtech.com
Using Power Management
Power management allows you to reduce overall power consumption by slowing down workstation activity when the workstation is idle. For more information about power consumption, refer to the HP Worksta...
zbz0529 Power technology
Lichee RV 86 PANEL Review (7) - Deploy a personal blog on Lichee
Lichee RV 86 PANEL Review (7) - Deploy a personal blog on Lichee RV In the previous section, we completed the hexo configuration for the Windos environment and the server deployment on the Lichee side...
jszszzy Special Edition for Assessment Centres
[NXP Rapid IoT Review] Bluetooth Control RGB
【NXP Rapid IoT Evaluation】Environmental Quality Test https://en.eeworld.com/bbs/forum.php?mod=viewthread&tid=1067645&fromuid=194541 (Source: Electronic Engineering World Forum) This paper mainly reali...
dvd1478 RF/Wirelessly
[National Technology N32G457 Review] Comparison between development board N32G457 and AB32VG1
[i=s]This post was last edited by jinglixixi on 2022-1-19 19:28[/i]The reason why the two development boards are compared together is actually accidental, that is, both of them use rt-thread studio as...
jinglixixi Domestic Chip Exchange
I2C pull-up levels
As shown in the figure, the level of the I2C pull-up resistor of the chip is 1.8V. If the microcontroller controls the high level of IO to 3.3V, can it work normally?This question came up after readin...
1nnocent stm32/stm8
It’s the middle of the year, how are your 2021 plans/goals going?
I went cycling last night and met a big guy. He said that this was his first time cycling in 2021. He bought some bicycle parts from overseas in the winter of 2020. Due to the epidemic and other reaso...
eric_wang Talking

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号