IEC Inlet Filters
With fuse holders and voltage selectors
A range of compact IEC 60320 inlet power entry modules combining
1 or 2 fuse holders for US and IEC fuses. Plus input voltage selector
with 4 possible combinations. These features ensure the range is
ideally suited for manufacturers of business, consumer and medical
equipment for international markets.
F.MF-F.MG
series
•
Current ratings from 1A to 6A
•
Integral single or twin fuse holder
•
Voltage selector
•
Snap-in or screw mount versions
•
Medical versions available
Mechanical Specifications
Manufacture:
metal case with built-in power line connector
according to IEC 60320, 1 (F.MF) or 2 (F.MG) fuse
holders for fuses 5 x 20mm (IEC) or 6.3 x 32mm
(US), voltage selector with 4 possible combinations;
internal components sealed with self-extinguishing
resin.
Connections:
IEC 60320 - Standard plug (INPUT);
faston 6.3 x 0.5mm or 2.8 x 0.5mm for filter
output terminals;
faston 2.8 x 0.5mm for fuse terminals;
faston 2.8 x 0.5mm for voltage selector terminals;
ground terminal connected to case.
F.MF.
01.– –.– –
01A. 04.– –.– –
07.– –.– –
02.– –.– –
3
2 x 2.5 0.047
2 x 2500
6
2x1
0.047
08.– –.– –
03.– –.– –
06A. 06.– –.– –
09.– –.– –
2 x 2500
F.MG. 03A. 05.– –.– –
1
2 x 10
0.047
Filter Range
(example pt no. - F.MF.01A.01.01.FA)
Code
l
R
(A)
L
(mH)
Cx
(µF)
Cy
(pF)
2 x 2500
I
L
(mA)
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
1
1
1
R
(MΩ)
Electrical Specifications
Rated voltage (V
R
):
max 250V, 50/60Hz
Rated current (I
R
):
Voltage test (2
S
.):
Climatic category:
Voltage selector:
referred to room temperature = 40°C
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
HPF (25/085/21);
Temperature range: -25°C to +85°C
110-220-240Vac
100-120-220-240Vac
115-115-230-230Vac
110-220Vac
Leakage current (I
L
):
at 220V, 50Hz, max value
F = 1 fuse
G = 2 fuses
A = Filter output terminals 2.8 x 0.5mm
C = Filter output terminals 6.3 x 0.8mm
F = Snap-in mounting
G = Screw mounting
01 = fuse 5 x 20mm + voltage selector 110-220-240V~
02 = fuse 5 x 20mm + voltage selector 100-120-220-240V~
03 = fuse 5 x 20mm + voltage selector 115-115-230-230V~
08 = fuse 6.3 x 32mm + voltage selector 110-220-240V~
09 = fuse 6.3 x 32mm + voltage selector 100-120-220-240V~
10 = fuse 6.3 x 32mm + voltage selector 115-115-230-230V~
15 = fuse 5 x 20mm + voltage selector 110-220V~
16 = fuse 6.3 x 32mm + voltage selector 110-220V~
19 = fuse 5 x 20mm + voltage selector 100-120-220-230V~
20 = fuse 6.3 x 32mm + voltage selector 100-120-230-240V~
21 = fuse 5 x 20mm + voltage selector 100-120-230-240V~
Approvals
29
IEC Inlet Filters
Insertion loss
(typical):
–––– Asymmetrical (line to ground) with Cy
F.MF-F.MG
series
Asymmetrical (line to ground) without Cy
– – – Symmetrical (line to line)
…01A.04. – – F & ...01A.07. – – F
...01A.01. – – F,
– – –
...01A...
…03A.05. – – F & ...03A.08. – – F
...03A.02. – – F,
– – –
...03A...
…06A.06. – – F & ... 06A.09. – – F
...06A.03. – – F,
– – –
... 06A...
…01A.04. – – G & ...01A.07. – – G
...01A.01. – – G,
– – –
...01A...
…03A.05. – – G, & ...03A.08. – – G
...03A.02. – – G
– – –
...03A...
…06A.06. – – G & ...06A.09. – – G
...06A.03. – – G,
– – –
...06A...
31