SERIES SFE*7*
ENGINEERING DATA SHEET
RAILWAY SOCKET
ECONOMICAL STYLE
Basic Socket Series Designation for:
Series F370, F470, F570, F670
and timers. Coding possibility using keys
devices adjustable by the user. To fit with H relay mounting style.
GENERAL CHARACTERISTICS
q
q
q
q
q
q
q
Monobloc design in thermoplastic resin.
Fire and smoke specification NFF 16-102 (requirement 3).
Electrical and environmental characteristics, in accordance with the relays characteristics.
Hardware corrosion resistance steel.
Crimp contacts in copper alloy.
Installation torque, relay 0.45Nm, socket on structure 0.6Nm.
Socket sealing plug for SFE37X/SFE47X/SFE67X: 11 0596 00 rear insertion.
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (33) 3 87 97 31 01 Tel: (852) 2 191 3830
Fax: (33) 3 87 97 96 86 Fax: (852) 2 389 5803
EUROPE
2 Rue Goethe
57430 Sarralbe
France
Featuring
LEACH
©
power and control solutions
www.esterline.com
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 10/10
- 94 -
Page 1 of 3
CONTACTS TYPES
Crimp contacts to plug in by the rear of the base.
For series SFE37X/SFE47X and SFE67X
SFE*7*
Insertion tool P/N:
AMP 91002-1
Extraction tool P/N:
AMP 305183.
Crimping tool:
q
P/N AMP 58945-2 or 91523-1 for contacts type 1 (size 18-16, wire section 0.75 to 1.50mm
2
q
P/N AMP 91521-1 for contacts type 2 (size 18-14, wire section 0.8 to 2.00mm
2
q
P/N AMP 91539-1 for contacts type 4 (size 18-16, wire section 0.8 to 1.40mm
2
For SFE570 only
Insertion and extraction tool:
main:
M81969/14-04
coil:
M81969/14-03
Crimping tool:
M22520/1/01 with turret M22520/1-02 or MS 3191-1
Contact may be provided separately (using contacts P/N).
NUMBERING SYSTEM
SFE *7* 1
1
Basic series designation__________________________|
|
|
|
1-socket series (370,470,570,D670)____________________|
|
|
2-Mounting Hardware_______________________________________|
|
3-Contact type________________________________________________|
Mounting
Code 0 =
Code 1 =
Code 2 =
Code 3 =
Code 4 =
hardware
without hardware
with key code M3
with key code UNC 4-40
with standoff key M3
with standoff key UNC 4-40
Contact type
Type 0 = without contacts
---------|
Type 1 = contacts 11 16 0306 (wire size 18-16)
|
Type 2 = contacts 11 16 0307 (wire size 14)
|-- SFE37X/SFE47X/SFE67X
|
Type 4 = contacts 11 16 0333 (wire size 18-16)
|
---------|
----|
Type 4 = main contacts 05 910 00 (wire size 12-14)
|
coil contacts 05 911 00 (wire size 16-18-20) |
|-- SFE570
Type 10 = main contacts 05 910 01 (wire size 16-18-20)|
coil contacts 05 911 00 (wire size 16-18-20)|
----|
Date of issue: 10/10