EEWORLDEEWORLDEEWORLD

Part Number

Search

H9423DA

Description
Rotary Coded Switch, 4 Positions, Decimal, Latched, 20A, 28VDC, Quick Connect Terminal, Spindle Actuator, Panel Mount, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size111KB,2 Pages
ManufacturerBULGIN
Websitehttp://www.bulgin.co.uk/
Environmental Compliance
Download Datasheet Parametric View All

H9423DA Overview

Rotary Coded Switch, 4 Positions, Decimal, Latched, 20A, 28VDC, Quick Connect Terminal, Spindle Actuator, Panel Mount, ROHS COMPLIANT

H9423DA Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeSPINDLE
body width18.5 mm
body height32 mm
Body length or diameter32.3 mm
Contact (AC) maximum rated R load16A@250VAC
Maximum contact current (AC)16 A
Maximum contact current (DC)20 A
Contact (DC) maximum rated R load20A@28VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)28 V
Manufacturer's serial number9100
Installation featuresPANEL MOUNT
Number of positions4
Number of switching segments1
surface mountNO
Switch actionLATCHED
switch functionDECIMAL
Switch typeROTARY CODED SWITCH
Termination typeQUICK CONNECT
Base Number Matches1
9100 Rotary Switches
16A 250Vac
2 to 6 way rotary switch
Ratings up to 16A,
250V ac; 20A, 28V dc
Pairs of single pole
change over contacts
In house test
16(4)A 250Vac T125
16A 400Vac T125
8(8)A 250Vac T125 5E4 (50,000 Operations)
UL CSA 20A Non Ind 277Vac, 250Vac 2hp, 125Vac 1hp
UL85°C, file no. E45221, CSA file no. LR10990
30A 12V dc
RoHS compliant
9100 switches are highly versatile with up to 6 positions at 30° intervals and
6 terminals per switch. For more complex switching (7 positions & over),
contact the factory. Two switches may be stacked to give up to 12 terminal
switching.
3mm contact gap.
Technical data on pages 4 & 5.
Wide choice of
switching circuits
Can be stacked together
RoHS
C 9 5 01 D A Stop at 120˚
ORDER FORMAT
TERMINAL
C
2
9.2
TERMINAL SERIES POSITIONS CIRCUIT SPINDLE BODY OPTIONS
CODE
CODE
CODE
CODE
CODE CODE
SERIES
POSITION
CIRCUIT
9100 switches offer almost infinite
switching options
For this reason it is impractical to show all the
options available.
SPINDLE
A
ø6.0
4.5
A/F
26.0
Switching
positions
B
The table below gives an example of a
5 position switching sequence:
6.3 x 0.8
ø6.0
4.5
A/F
22.0
OFF, 1, 1+2, 1+2+3, 1+2+3+4
C
3
Switching
positions
1
A
2
3
B
Off
Pos 1 Pos 2 Pos 3 Pos 4 Pos 5
ø6.0
4.5
A/F
10.8
D
ø6.05
4.65
A/F 12.2
M
ø6.0
15˚
4
5 A.65
/F
4
9
H
Switching
positions
4
12.2
The code
for your chosen circuit will be
allocated by our technicians.
Please contact the factory for details.
N
ø6.0
4.5
A/F
20.0
9.2
Use the blank table to plan your switching
up to 6 positions.
P
4.5
A/F
ø6.0
23.0
5
4.8 x 0.8
For approval information on H terminals,
contact the factory.
1
A
2
Switching
positions
Pos 1 Pos 2 Pos 3 Pos 4 Pos 5 Pos 6
R
4.5
ø6.0
A/F 12.2 20.1
for 2 gang switching
S
5
4. /F
A
˚
45
ø6.0
10.8
6
Simple circuits may not use all terminals.
Unnecessary terminals may be omitted.
Switching
positions
3
B
4
L
supplied without spindle
64
ARCOLECTRIC CORPORATION
31-315 Plantation Drive, Thousand Palms, CA 92276 Tel: 760-343-3650 Fax: 760-343-3651 email: info@arcolectric.com
SD cards all have 4GB/s!
SD EXPRESS BRINGS NEW GIGABYTE SPEED TO SD MEMORY CARDSMemory cards can transfer up to 4GB/s using PCIe 4.0 architectureMay 19, 2020—The SD Association today announced that the SD 8.0 specification fo...
Jacktang Microcontroller MCU
Can DSP28335 realize real-time acquisition of multiple signals?
Experts, I want to use DSP28335 to realize real-time acquisition of 6-channel signals. Is it possible?...
steven_goo DSP and ARM Processors
quartus18.1
Error (10054): Verilog HDL File I/O error at ROM.v(15): can't open Verilog Design File "rom_init.dat". Please help. What should I do if I encounter this problem? Reinstalling the software doesn't help...
我去我去 FPGA/CPLD
Components Science Popularization: Working Principle Analysis of Thermal Protector
[size=5]Thermal relays are protective devices used for overload protection of motors or other electrical equipment and electrical circuits. [/size] [size=5] [/size] [size=5]In actual operation of the ...
fish001 Analogue and Mixed Signal
Who knows the principle of voltage doubling circuit? No transformer or inductor is used, just a few diodes and capacitors...
Who knows the principle of voltage doubling circuit? No transformer or inductor is used, just a few diodes and capacitors are used to increase the voltage. I don't know how much load capacity this vol...
QWE4562009 Discrete Device

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号