Part Number

Search

MI-26MMV

Description
1-OUTPUT DC-DC REG PWR SUPPLY MODULE, PLASTIC, MODULE-9
CategoryPower/power management    The power supply circuit   
File Size83KB,2 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet Parametric View All

MI-26MMV Overview

1-OUTPUT DC-DC REG PWR SUPPLY MODULE, PLASTIC, MODULE-9

MI-26MMV Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Parts packaging codeMODULE
package instruction,
Contacts9
Reach Compliance Codecompliant
Other featuresREMOTE SHUTDOWN
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
CertificationCE
Efficiency (main output)90%
high12.7 mm
Maximum input voltage400 V
Minimum input voltage125 V
Nominal input voltage270 V
JESD-30 codeR-XDMA-P9
JESD-609 codee0
length116.6 mm
Maximum grid adjustment rate0.5%
Maximum load regulation0.2%
Number of functions1
Output times1
Number of terminals9
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
Maximum output voltage11 V
Minimum output voltage9 V
Nominal output voltage10 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
Ripple voltage (main output)0.05304 Vrms
surface mountNO
technologyHYBRID
Temperature levelOTHER
Terminal surfaceTIN LEAD OVER COPPER
Terminal formPIN/PEG
Terminal locationDUAL
Maximum time at peak reflow temperatureNOT SPECIFIED
Fine-tuning/adjustable outputYES
width60.7 mm
Base Number Matches1
MI-200
Features
TM
Military DC-DC Converters 50 to 100W
Inputs:
28Vdc per MIL-STD-704D/E
155Vdc per MIL-STD-1399A
270Vdc per MIL-STD-704D/E
Single output: 2 – 48Vdc
Up to 23W/in
3
MIL-STD-810 environments
Current limit
OVP and thermal shutdown
Power boosters for
higher power outputs
ZVS/ZCS power architecture
Low noise FM control
Size: 4.6" x 2.4" x 0.5"
(116,8 x 61,0 x 12,7mm)
Product Highlights
The MI-Series is designed for
military applications and is based
on Vicor’s 1st Generation family of
zero-current/zero-voltage switching,
component level DC-DC converters.
Operating at frequencies in excess
of 1MHz, the MI-Series offers
state-of-the-art performance in
terms of power density, efficiency,
noise, ease of use, and reliability.
All units are manufactured in ISO
9001-registered facilities. Full
epoxy encapsulation in Vicor’s
industry standard package
enables the MI-Series to meet
MIL-STD-810 environmental
requirements for humidity,
fungus, salt, fog, explosive
atmosphere, acceleration,
vibration, and shock. (See page 32.)
Standard features such as wide
output trimming/programming,
current limiting, remote sense,
output inhibit, and latching
OVP and OTP combine to offer
a high degree of protection,
versatility, and reliability for
military power systems.
Up to 90% efficiency
Remote sense
Converter/Booster Specifications
(At TBP = 25°C, nominal line and 75% load, unless otherwise specified)
PARAMETER
Input Characteristics
Input voltage range
No load power dissipation
Output Characteristics
Set point accuracy
Load/line regulation
Output temperature drift
Output noise - pp
Output voltage trimming
(1)
Remote sense compensation
OVP set point
(2)
Current limit
Short circuit current
(3)
Control Pin Characteristics
Gate-in high threshold
Gate-in low threshold
Gate-in low current
Power sharing accuracy
Isolation Characteristics
Isolation (input to output)
Isolation (output to baseplate)
Isolation (input to baseplate)
Input/output capacitance
Environmental (MIL-STD-810)
Altitude - method 500.2
Humidity - method 507.2
Acceleration - method 513.3
Vibration - method 514.3
Shock - method 516.3
50
0.5
115
105
20
MIN
TYP
MAX
UNITS
TEST CONDITIONS
See input voltage chart
1.35
2.0
0.5
0.05
0.2
0.01
1.0
100
1.0
0.2
0.5
0.02
1.5
150
110
135
125
130
Watts
% Vnom
% Vnom
% Vnom
%/°C
% Vnom
mV
% Vnom
Vdc
% Vnom
% Inom
% Inom
Vdc
Vdc
mA
LL to HL, 10% to FL
LL to HL, NL to 10%
}
Whichever is greater
20MHz BW
125
Latching
Auto restart
6
0.65
0.95
3,000
500
1,500
50
70,000
86 / 240
9
20
40
2,478,477
584,920
483,303
80-90
0.07
95
75
6
1.05
Vrms
Vrms
Vrms
pF
feet
% / hours
g's
g's
g's
hours
hours
hours
%
°C/W
°C
°C
°C
ounces (grams)
Procedure II
Procedure 1, cycle 1
Procedure 2
Procedure 1, category 6
Procedure 1
Reliability (MIL-HDBK-217F)
25°C Ground Benign: G.B.
50°C Naval Sheltered: N.S.
65°C Airborne Inhabited Cargo: A.I.C.
Thermal Characteristics
Efficiency
Baseplate to sink
Thermal shutdown
90
Baseplate operating temperature
Storage temperature
Mechanical Specifications
Weight
(1)
(2)
105
+85
+100
With thermal pads
Latching
See product grade
See product grade
6.0 (170)
MI-200 10/02
1 of 2
10V, 12V, and 15V outputs, standard trim range ±10%. Consult factory for wider trim range.
No over temperature or voltage protection in booster modules.
(3)
Output voltages of 5V or less incorporate foldback current limiting; outputs of 10V and above provide
constant current limiting.

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号