P23-060KI

Description
AC-DC Regulated Power Supply Module, 2 Output, 6W, Hybrid,
CategoryPower/power management    The power supply circuit   
File Size229KB,2 Pages
ManufacturerSemiconductor Circuits Inc
Download Datasheet Parametric View All

P23-060KI Overview

AC-DC Regulated Power Supply Module, 2 Output, 6W, Hybrid,

P23-060KI Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerSemiconductor Circuits Inc
package instruction,
Reach Compliance Codeunknown
ECCN codeEAR99
Is SamacsysN
Other featuresADDITIONAL -15V OUTPUT ALSO AVAILABLE
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage252 V
Minimum input voltage200 V
JESD-30 codeR-XXMA-X
Maximum load regulation0.05%
Number of functions1
Output times2
Maximum operating temperature71 °C
Minimum operating temperature-25 °C
Maximum output voltage15.15 V
Minimum output voltage14.85 V
Nominal output voltage15 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelCOMMERCIAL EXTENDED
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output6 W
Fine-tuning/adjustable outputNO
Base Number Matches1
AC/DC
6 Watts
Single/Dual Outputs
CM, P, PA Series
High performace design
Ultra-low noise
Continuous short circuit
protection
Specifications
T
he CM, P and PA Series boast
over a decade of reliable, field
proven service and are the
recognized industry standard for high
performance AC/DC power supplies.
The PA Series is equipped with industry
standard 2.2” pin spacing while the P
Series is 2.0”.
The CM Series are high performance
chassis mount versions employing a
top-mounted, five terminal barrier strip
for power entry and exit. These units
are ideal for systems that are best
implemented with “hard wire” power
cabling techniques. Features include
MTBF’s of greater than 150,000 hours,
lower case temperature rise (to 18°C
cooler) and the high in-circuit perfor-
mance. This higher efficiency results in
lower ambient temperatures and
greater system reliability. Dual output
tracking is standard.
INPUT
Voltage and Frequency
Standard
Suffix I
Suffix N
Suffix K
Suffix K2
105 to 125 Vac - 50 to 440 Hz
200 to 252 Vac - 50 to 60 Hz
90 to 110 Vac - 50 to 60 Hz
200 to 252 Vac - 50 to 60 Hz
105 to 125/210 to 250 Vac
OUTPUT
Voltage Tolerance
Ripple and Noise (PARD)
Short Circuit Protection
Temperature Coefficient
± 1%
1mV RMS
Current Limiting
0.02% / °C
GENERAL
I/O Isolation
Suffix I
1500 Vac
2500 Vac
ENVIRONMENTAL
Operating Temperature Range
Storage Temperature Range
Cooling
-25°C to +71°C-No Derating
-25°C to +85°C
Free-air Convection
All specifications are typical at nominal line and full load at 25°C unless otherwise noted and
are subject to change without notice.
[Flower carving DIY] Interesting and fun music visualization project (11) --- WS2812 fantasy light strip
I had the urge to do a series of topics on sound visualization. This topic is a bit difficult and covers a wide range of areas. The related FFT and FHT algorithms are also quite complicated, but I sti...
eagler8 DIY/Open Source Hardware
Prize-winning live broadcast | Application registration for ON Semiconductor's high-efficiency products in smart fast charging is open!
Prize-winning live broadcast | Application registration for ON Semiconductor's high-efficiency products in smart fast charging is open!Click here to register for the live broadcastLive broadcast time:...
EEWORLD社区 Power technology
Draw a SparkRoad RGB LCD expansion board
This is my first time to adjust the display driver. I didn't know much about LCD display interfaces before. This time I bought three models, one that supports i80 CPU interface, one that supports MDDI...
littleshrimp Domestic Chip Exchange
Common protection circuits for switching power supplies - overheating, overcurrent, overvoltage and soft start protection circuits
1 Introduction With the development of science and technology, the relationship between power electronic equipment and people's work and life is becoming increasingly close, and electronic equipment c...
木犯001号 Power technology
Hundreds of drones lost control and crashed into buildings. Are programmers to blame?
[Source: CSDN] The crash of a drone may not be unusual, but the crash of dozens or even hundreds of drones into a building is too "spectacular". According to netizens, on the evening of January 25, hu...
eric_wang Talking
[Lazy self-care fish tank control system] BLE_MESH network test, multiple elements are not allowed
[Lazy self-care fish tank control system] BLE_MESH network test, multiple elements are not allowed Purpose: In the application, I want to arrange several sensors at different locations, and then use B...
蓝雨夜 onsemi and Avnet IoT Innovation Design Competition

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号