EEWORLDEEWORLDEEWORLD

Part Number

Search

NVFMAS25DC12V1.2AD

Description
Switching capacity up to 25A
File Size146KB,2 Pages
ManufacturerDBLECTRO
Websitehttp://www.dblectro.com
Download Datasheet View All

NVFMAS25DC12V1.2AD Overview

Switching capacity up to 25A

NVFMAS25DC12V1.2AD Preview

23×15.5×26
Features
Switching capacity up to 25A.
PC board mounting and insert mounting available.
Suitable for automation system and automobile auxiliary etc.
Ordering Information
NVFM C
Z 20
DC12V 1.5 b
7
D
8
5 Coil rated Voltage(V):DC:6,12,24,48
6 Coil power consumption:1.2:1.2W;1.5:1.5W
7 Terminals b: PCB type;a: plug in type
8 Coil transient suppression: D: with diode;
R: with resistant;.
NIL: standard
1
2
3
4
5
6
1 Part number:NVFM
2 Contact arrangement:A:1A (1.2W);C:1C(1.5W)
3 Enclosure:S: Sealed type;Z: Dust cover;
4 Contact Current:25:25A/14VDC;20:20A/14VDC
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation
Electrical
life
Mechanical
1A SPSTNO
f1C
SPDT(B-M)
Ag SnO
2
, AgNi Ag CdO
1A 25A/14VDC 1C 20A/14VDC
350W
75VDC
Max. Switching Current:25A
50m
Item 3.12 of IEC255-7
5
10
Item 3.30 of IEC255-7
10
7
Item 3.31 of IEC255-7
Coil Parameter
Coil voltage
VDC
Pickup
voltage
VDC(max)
(70%of rated
voltage )
release
voltage
VDC(min)
(10% of rated
voltage)
0.6
1.2
2.4
4.8
0.6
1.2
2.4
4.8
1.5
10
7
1.2
10
7
Dash
numbers
Coil
resistance
±10%
Coil power
consumption
W
Operate
Time
ms
Release
Time
ms
Rated
006-1200
012-1200
024-1200
048-1200
006-1500
012-1500
024-1500
048-1500
6
12
24
48
6
12
24
48
Max.
7.8
15.6
31.2
62.4
7.8
15.6
31.2
62.4
30
120
480
1920
24
96
384
1536
4.2
8.4
16.8
33.6
4.2
8.4
16.8
33.6
CAUTION
:
1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
143
-40~85’
Ambient Temperature
85% (at 40’)
IEC68-2-3 Test Ca
Relative Humidity
Mass
18.5g
Note: 1). ,When testing, coil terminals shall be connect , if coil transient suppression is installed in relay .
Qualification inspection:
Perform the qualification test as specified in the table
of IEC255-19-1 and minimum sample size 24.
Dimensions (Unit: mm)
>àçÇá
nãîÜ>àç>ìòèÑ
Mounting (Bottom views)
na`>>ìòèÑ
Note: Footprint as shown above
is also available.
Dimensions
Wiring diagram (Bottom views)
mm
0.8
1.4
2.1
2.4
2.5
2.7
3.2
4.5
4.8
5.5
6.3
6.4
8
9
9.5
11.5
14
15
15.5
23
26
0.031
0.055
0.083
0.094
0.098
0.106
0.126
0.177
0.189
0.127
0.248
0.252
0.315
0.354
0.374
0.453
0.551
0.591
0.610
0.905
1.024
NOTES
1).Dimensions are in millimeter.
2).Inch equivalents are given for general information only.
Reference Data

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号