RP
RP610 Series
RP610
HIGH PERFORMANCE TO 20A
DC FILTER
ROHS COMPLIANT
RADIUS POWER
Your Power Partner
High Performance Single Stage DC Power Line Filter
SPECIFICATIONS
Max. Operating Voltage
Ambient Temperature
Climatic Category
Hipot Rating (L-G)
Terminals (-T)
Typ. Weight, LBS (KG)
:
:
:
:
:
:
250VDC
-25 to 55C
25/100/21
1800VDC
QD: 0.25 Tabs
0.7 (0.3)
SCHEMATIC
PART NUMBER/ ORDERING
RP610
-X
(Amps)
3
6
10
12
20
Note:
Use any combination of -Y with any -X (Amps) rating
e.g. RP610-20-10-QD (20 Amps with 10nF Y-cap)
-Y
(Ycap, nF)
10
100
1000
-T
QD
www.radiuspower.com
Reference purposes only.
Specifications are subject to change.
Consult factory to verify specifications.
Engineering Assistance: engg@radiuspower.com
Sales:sales@radiuspower.com
132
RP
RP610
Typical Insertion Loss, dB (50/50ohm) Mechanical Dimensions
RADIUS POWER
Your Power Partner
3 Amp
FREQ (MHz)
CM (dB)
DM (dB)
.15
40
40
.5
55
60
1
65
65
10
65
75
30
60
70
6 Amp
FREQ (MHz)
CM (dB)
DM (dB)
.15
40
42
.5
55
62
1
65
65
10
65
75
30
60
70
10/12 Amp
FREQ (MHz)
CM (dB)
DM (dB)
.15
40
45
.5
55
65
1
65
65
10
65
75
30
60
70
TYPICAL TOLERANCE: +/-0.02 (0.50)
20 Amp
FREQ (MHz)
CM (dB)
DM (dB)
.15
20
30
.5
28
55
1
34
58
10
55
60
30
60
60
www.radiuspower.com
Reference purposes only.
Specifications are subject to change.
Consult factory to verify specifications.
Engineering Assistance: engg@radiuspower.com
Sales:sales@radiuspower.com
133
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Astrodyne TDI
:
RP610-6-100-QD