Information Technology Equipment, General Requirements for Safety
Information Technology Equipment, General Requirements for Safety
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
Medical Electric Equipment, General Requirements for Safety and
Essential Performance. (CB Scheme)
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
Safety requirements for electrical equipement for measurement, control
and laboratory use
EAC
RoHs 2+
Report / File Number
1605077-14
2207629
2207629
E314885-A5-UL
E314885-A5-CB-1
1205098-1
T1301251-313
RU-AT.37.02367
Standard
EN60950-1: 2006 + AM2:2013
IEC60950-1-2005 , 2nd Edition + AM2:2013
ANSI/UL60950-1, 1st Edition
CAN/CSA C22.2 No. 60950-1
UL60601-1, 1st Edition
CAN/CSA C22.2 No. 60601-1:2008
ANSI/AAMI ES60601-1:2005 +A2:10
CAN/CSA-C22.2 No. 60601-1:2008
IEC60601-1:2005 + C2:2007
EN60601-1:2006
IEC60601-1:2005 + C2:2007
EN61010:2010
IEC61010:2010, 3rd Edition
TP TC 004/2011
RoHS (10/10)
EMC Compliance
Electromagnetic compatibility of multimedia equipment -
Emission requirements
Condition
with external filter
continued on next page
Standard / Criterion
EN55032, Class A/B
www.recom-power.com
REV.: 5/2018
ECO-4
RxxP2xxS_D/R
DC/DC Converter
Specifications
(measured at Ta= 25°C, nominal input voltage, full load)
EMC Filtering Suggestions according to EN55032 Class A and Class B
Sinlge Output
Dual Output
C3
C3
L1
L1
+V
IN
+V
IN
C1
C1
-V
IN
-V
IN
C2
C2
-V
OUT
-V
OUT
-V
IN
-V
IN
+V
OUT
+V
OUT
+V
IN
+V
IN
C1
C1
C2
C2
L1
L1
+V
OUT
+V
OUT
COM
COM
-V
OUT
-V
OUT
Series
C3
C3
Component List Class A
C1
10µF 100V MLCC
Component List Class B
L1
C3
470pF
C1
C1
L1
12µH choke
WE 744 045 120
C3
470pF
3.9µH choke
WE 744 045 0039
10µF 100V MLCC 2.2µF 100V MLCC
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Material
Dimension (LxWxH)
Weight
Type
case
potting
PCB
Value
non-conductive black plastic, (UL94 V-0)
silicon rubber compound, (UL94 V-0)
FR4, (UL94 V-0)
19.5 x 9.8 x 12.5mm
4.3g typ.
Dimension Drawing (mm)
embossed logo
19.5
9.8
Marking
4.10
0.50
+0.10/-0.05
0.25
±0.05
Pin Connection
Pin # Single
1
+Vin
2
-Vin
5
-Vout
6
No Pin
7
+Vout
Tolerance:
Dual
+Vin
-Vin
-Vout
Com
+Vout
/X2
+Vin
-Vin
No Pin
-Vout
+Vout
0.51
12.5
Recommended Footprint Details
Bottom View
1 2
5
6 7
2.54
2.4
xx.x= ±0.5mm
xx.xx= ±0.25mm
1 2
5 6 7
Top View
3x2.54= 7.62
1.9
6x2.54= 15.24
2.54
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Packaging Quantity
Storage Temperature Range
Storage Humidity
Type
tube
tube
Value
520.0 x 22.3 x 12.0mm
25pcs
- 55°C to +125°C
95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.