SINGLE-PHASE GLASS PASSIVATED
SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 25 Amperes
*
*
*
*
MP2505
THRU
MP2510
FEATURES
Superior thermal desing
300 amperes surge rating
//
1/4 universal faston terminal
Hole thru for # 10 screw
MECHANICAL DATA
MP-25
Max. .311 (7.9)
.480 (12.2)
.425 (10.8)
* UL listed the recognized component directory, file #E94233
* Epoxy: Device has UL flammability classification 94V-O
1.142 (29)
1.102 (28)
.673 (17.1)
.634 (16.1)
Hole for # 10 screw
Min f.200 (5.08)
.732 (18.6)
.693 (17.6)
.673 (17.1)
.583 (14.8)
.543 (13.8)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25
o
C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
.32 x .252 (0.81 x 6.35)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS
(At T
A
= 25
o
C unless otherwise noted)
RATINGS
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Bridge Input Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Output Current at Tc = 55 C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
RMS isolation voltage from case to lead
Typical Thermal Resistance (from junction to case)
Typical Thermal Resistance (from junction to ambient)
Operating and Storage Temperature Range
ELECTRICAL CHARACTERISTICS
(At T
A
= 25 C unless otherwise noted)
CHARACTERISTICS
Maximum Forward Voltage Drop per element at 12.5A DC
Maximum Reverse Current at Rated
DC Blocking Voltage per element
@T
A
= 25 C
@T
C
= 100 C
o
o
o
o
SYMBOL
V
RRM
V
RMS
V
DC
I
O
I
FSM
V
ISO
R
θ
JC
R
θ
JA
T
J,
T
STG
MP2505
50
35
50
MP251
100
70
100
MP252
200
140
200
MP254
400
280
400
25.0
300
2500
1.9
19
-55 to + 150
MP256
600
420
600
.634 (16.1)
MP258
800
560
800
1.142 (29)
1.102 (28)
MP2510 UNITS
1000
700
1000
Volts
Volts
Volts
Amps
Amps
Volts
0
C/W
0
C
SYMBOL
V
F
I
R
MP2505
MP251
MP252
MP254
1.1
5.0
0.2
MP256
MP258
MP2510 UNITS
Volts
uAmps
mAmps
2015-03
REV: B
NOTE: 1. Suffix ”W” for wire type
2. ”Fully ROHS compliant”,”100% Sn plating(Pb-free).
RATING AND CHARACTERISTIC CURVES ( MP2505 THRU MP2510 )
FIG. 1 - MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
PEAK FORWARD SURGE CURRENT, (A)
FIG. 2 - TYPICAL FORWARD CURRENT
DERATING CURVE
25
AVERAGE FORWARD CURRENT, (A)
8.3ms Single Half Sine-Wave
(JEDEC Method)
20
500
400
300
200
100
0
15
10
60 Hz RESISTIVE OR
INDUCTIVE LOAD
5
0
1
2
4 6 8 10
20
40 60 80100
NUMBER OF CYCLES AT 60Hz
INSTANTANEOUS REVERSE CURRENT, (uA)
0
50
100
CASE TEMPERATURE, (
150
)
175
INSTANTANEOUS FORWARD CURRENT, (A)
100
FIG. 3- TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
FIG. 4 - TYPICAL REVERSE CHARACTERISTICS
100
10
TJ = 25
Pulse Width = 300us
1% Duty Cycle
10
TJ = 25
1
1.0
.1
.01
.6
1.2 1.3
.7
.8
.9
1.0
1.1
INSTANTANEOUS FORWARD VOLTAGE, (V)
0.1
0
20
40
60
80
100 120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE, ( %)
RECTRON
Attachment information about MP25X
1.
Internal Circuit
2. Marking on the body
AC
Part No.
Rectron Logo
+
MP25X
VXXX
Voltage-code
05-------50V
1-------100V
2-------200V
4-------400V
6-------600V
8-------800V
10-----1000V
Plant - code
Year - code
Week - code
3. Items marked on the inner box and carton
3.1 On the box (for –B)
CUSTOMER
TYPE
UL Logo
LOT NO.
QUANTITY
Q.A.
DATE
3.2 On the carton
CUSTOMER
TYPE
QUANTITY
LOT NO.
REMARK
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
BULK PACK
PACKAGE
MP-15/-25/-35
PACKING CODE
-B
EA PER BOX
50
INNER BOX SIZE
(mm)
206*208*45.5
CARTON SIZE
(mm)
450*220*255
EA PER CARTON
500
GROSS
WEIGHT(Kg)
9.6
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi-
lity for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" paramet-
ers which may be included on RECTRON data sheets and/ or specifications ca-
n and do vary in different applications and actual performance may vary over ti-
me. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other rela-
ted applications where a failure or malfunction of component or circuitry may di-
rectly or indirectly cause injury or threaten a life without expressed written appr-
oval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rect-
ron Inc and its subsidiaries harmless against all claims, damages and expendit-
ures.