EEWORLDEEWORLDEEWORLD

Part Number

Search

HWS305

Description
AC/DC CONVERTER 5V 30W
CategoryPower/power management   
File Size482KB,2 Pages
ManufacturerTDK-LAMBDA
Environmental Compliance
Download Datasheet Parametric View All

HWS305 Overview

AC/DC CONVERTER 5V 30W

HWS305 Parametric

Parameter NameAttribute value
typeopen framework
Number of outputs1
Voltage - input85 ~ 265 VAC
Voltage - Output 15V
Voltage - Output 2-
Voltage - Output 3-
Voltage - Output 4-
Current - Output (maximum)6A
Power (W)30W
applicationITE (Business)
Voltage - Isolation3kV
efficiency80%
Operating temperature-10°C ~ 70°C (with derating)
characteristicAdjustable output, DC input capability, universal input
Installation typeBase installation
size/dimensions3.74" long x 1.04" wide x 3.23" high (95.0mm x 26.4mm x 82.0mm)
Minimum load required-
ApprovalCE
HWS15A-150A/A Series
50-150W Single Output Industrial Power Supplies
Features
Limited Lifetime Warranty
UL508 approved
SEMI F47 Compliant (high line AC)
Universal Input (85 - 265VAC)
Higher Efficiency Than HWS series
Key Market Segments & Applications
Specifications
Model
Input Voltage Range
Input Current (Typ) (1)
Inrush Current (1)
-
A
A
-
Power Factor (1)
-
Temperature Coefficient
%/°C
Overcurrent Protection
%
Overvoltage Protection
V
Hold Up Time (Typ)
ms
Leakage Current (max)
mA
Remote Sense
-
Indicator
-
Operating Temperature (with cover) °C
Storage Temperature
°C
Humidity (non condensing)
%RH
Cooling
-
Withstand Voltage
VAC
Isolation Resistance
M Ohms
Vibration (non operating)
-
Shock
m/s
2
Safety Agency Approvals
-
Line Dip
-
Conducted & Radiated EMI
-
Immunity
-
Weight (Typ)
g
Size (WxHxD) (with cover)
Inches
mm
MTBF - Telcordia SR-332 issue 3**
Hours
Warranty
-
HWS15A/A
HWS30A/A
HWS50A/A
HWS100A/A
HWS150A/A
85 - 265VAC (47 - 63Hz) or 120 - 370VDC* (Withstands 300VAC for 5s)
0.35 / 0.2
0.65 / 0.4
0.65 / 0.35
1.3 / 0.65
1.9 / 0.95
14 / 28
Meets EN61000-3-2
-
-
0.97/0.91
0.98/0.93
0.98/0.93
<0.02%/°C
>105%
Yes
20
>0.5mA (Typ 0.2mA at 100VAC, 0.4mA at 230VAC)
No
Yes
Green LED = ON
-10°C to +70°C, derate linearly to 20% load from 50°C to 70°C (2)
-30 to +85°C
Operating: 30 - 90%RH, Non operating 10 - 95%RH
Convection
Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour
< 196.1 m/s
2
UL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark
Complies with SEMI F47 (200VAC line only)
EN55011 / EN55022-B, FCC-B, VCCI-B
IEC61000-4-2, -3, -4, -5, -6, -8, -11; IEC61000-6-2
190
240
300
470
520
1.24x3.23x3.15 1.24x3.23x3.74 1.24x3.23x4.72
1.3x3.23x6.3
1.65x3.23x6.3
31.5x82x80
31.5x82x95
31.5x82x120
33x82x160
42x82x160
12,116,851
8,169,868
3,726,622
2,963,512
2,676,081
Limited lifetime warranty (See website for terms & conditions)
* Safety certified for AC input only ** 24V output model, 25°C ambiient, full load, 230VAC input
(1) 100/200VAC
(2) HWS15A/A derates linearly to 50% load from 50 to 70°C
1-800-526-2324 • www.us.tdk-lambda.com/lp/
14
Disclaimer: us.tdk-lambda.com/lp/legal.htm
Take out an idle 100w shortwave amplifier with powerful performance
[i=s]This post was last edited by Stephenhu1984 on 2020-5-9 21:46[/i]The Xiaodantart PA100 shortwave amplifier has a maximum output power of 100 watts and is well made. It supports QRPradios such as K...
Stephenhu1984 Buy&Sell
PCI device RTX driver development method
1. When operating peripherals under RTX, you need to move the device from Windows to RTX. For specific migration methods, please refer to the section Converting a Windows Device to an RTX Device in th...
trueleven Industrial Control Electronics
Please help me analyze the working principle of MOSFET drive circuit
I need an expert to analyze the working principle of MOSFET drive circuit. My analog electronics knowledge is too poor. :Cry:...
Larry.xu Motor Drive Control(Motor Control)
Supercapacitors: Backup Power Solutions
The increase in applications that require instantaneous backup power has led to an increase in demand for supercapacitors. Supercapacitors (also known as ultracapacitors) are electrochemical capacitor...
qwqwqw2088 Analogue and Mixed Signal
Power amplifier experiment case (III) Car reversing radar system - ultrasonic transducer application
Do you know the principle of car reversing radar? Power amplifier experiment case (III) Car reversing radar system - application of ultrasonic transducer...
aigtekatdz Test/Measurement
[Disclaimer] Outsourcing projects, a great opportunity to make extra money!
[font=微软雅黑][size=3]【Disclaimer Forwarding】[/size][/font][font=微软雅黑][size=3] [/size][/font] [font=微软雅黑][size=3]Here is an outsourcing project. If you have the energy and ability, please contact us:)[/s...
eric_wang Buy&Sell

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号