Volgen America-SP15u series
Page 1 of 2
15-WATT, Universal Input
Fully Enclosed Switching Power Supply
ELECTRICAL SPECIFICATIONS
All specifications are typical at nominal input, full loa
INPUT SPECIFICATIONS
Input Voltage . . . . . . . . . . . . . AC 85V -264V
DC 110V-340V
Input Frequency .. . . . . . . . . . . 47 ~63 Hz
Input Current (100V) . . . . . . . . 0.17 ~ 0.36A
Inrush Current (100V, 50Hz). . . 12 ~ 24A
OUTPUT SPECIFICATIONS
FEATURES
Universal Input (AC85-264V)
Built_In Overvoltage Protection
Overcurrent Protection
Lightweight Construction
Metal Chassis with Cover
Compact, Low-Profile Package
3-Year Warranty
Output Voltage . . . . . . . . . . . . see chart
Output Adjustment . . . . . . . . ..
10%
Efficiency . . . . . . . . . . . . . . . . 70 ~ 79%
Over-Voltage Protection . . . . . . Zener Limiter
Over-Current Protection . . . . . . Automatic Recovery
Ripple and Noise . . . . . . . . . . . 150 mVp-p max.
Hold-Up Time . . . . . . . . . . . . . 15 - 100 mS
Line/Load Regulation . . . . . . . . see chart
Rise Time . . . . . . . . . . . . . . . . 100 mS max.
Leakage Current
(10023VAC)
. . . . Vin= 100V 0.5mA m
.
Vin= 230V 0.75mA
GENERAL SPECIFICATIONS
MTF . . . . . . . . . . . . . . . . . . . .
Isolation Voltage
Primary to Secondary . . . .
Primary to Case . . . . . . . .
Secondary to Case . . . . . .
Isolation Resistance . . . . . . . .
Efficiency . . . . . . . . . . . . . . . .
211,000 Hours
3000 VDC
1500 VDC
500 VDC
10*Ohms
Up to 85%
SAFETIES / EMI
ENVIRONMENTAL SPECIFICATIONS
FCC-B
EN 55022-B
VCCI-II
0* ~ 60*C
Derates linearly 2.5%
50*C
Cooling . . . . . . . . . . . . . . . . . Convection
Temperature Coefficient. . . . .. .0.02% / *C
Humidity . . . . . . . . . . . . . . . . 20-85% Rh (non-co
Storage Temperature. . . . . . . . -20*C ~ 85*C
Shock Vibration . . . . . . . . . . . Shock: 20G
(3 directio
Vibration: 10 ~ 55Hz
Operating Temperature
Range .
http://www.volgen.com/datasheet/prd_SP15U.html
9/15/2003
Volgen America-SP15u series
Page 2 of 2
PHYSICAL SPECIFICATIONS
Metal Enclosed - Terminal Block
OUTPUT
VOLTAGE
3.3 VDC
5 VDC
12 VDC
15 VDC
24 VDC
48 VDC
MODEL
OUTPUT CURRENT
EFFICIENCY LINE REGULATION LOAD REG
@100V
SP15U-03S
SP15U-05S
SP15U-12S
SP15U-15S
SP15U-24S
SP15U-48S
3.0 A
3.0 A
1.3 A
1.0 A
0.7 A
0.35 A
@230V
3.6 A
3.6 A
1.5 A
1.2 A
0.8 A
0.4 A
70%
73%
77%
77%
78%
79%
20 mV max.
20 mV max.
30 mV max.
30 mV max.
30 mV max.
30 mV max.
40 mV
50 mV
50 mV
50 mV
50 mV
50 mV
• No. 6-32 mounting hol
• Dimensions in mm
• Terminal block or "pin
type connector availab
Note:
All specifications typical and nominal / full load and 25*C unless otherwise noted.
Mounting screw length should not exceed 0.31 inches or 8 mm.
Avoid sustained operation in overload or dead short conditions.
Specifications subject to changes without notice.
http://www.volgen.com/datasheet/prd_SP15U.html
9/15/2003