TECHNICAL BULLETIN TB-5521
Air-Assisted Ion Bars
Installation, Operation and Maintenance
High Voltage
Out
Item #
Description
Air-Assisted Ion Bar Assembly, 12", 4 Emitters
Air-Assisted Ion Bar Assembly, 24", 8 Emitters
Made in America
Power Switch
94220
94221
94222
94223
94224
94225
94226
Positive On
LED
Air-Assisted Ion Bar Assembly, 36", 12 Emitters
Air-Assisted Ion Bar Assembly, 48", 16 Emitters
Air-Assisted Ion Bar Assembly, 60", 20 Emitters
Air-Assisted Ion Bar Assembly, 72", 24 Emitters
Air-Assisted Ion Bar Assembly, 96", 32 Emitters
Controller with Recessed Potentiometer Adjustment, 120V
Controller with Recessed Potentiometer Adjustment, 220V
Controller with External Potentiometer Adjustment, 120V
Controller with External Potentiometer Adjustment, 220V
Air Assisted Filter Regulator with Hose
Ion Bar 2 to 1 Connector Set (2 per pack)
Emitter for Air-Assisted Ion Bar
94240
94241
94245
94246
Balance
Adjustment*
Negative On
LED
Rate
Adjustment
94253
94250
94251
Power LED
(Blue)
*Balance Adjustment:
Clockwise- Positive
Counter clockwise- Negative
For more information on the Ion Bar sizes and
dimensions, see page 2.
INSTALLATION
I.
Install the controller console on or near the target
area. It must be close enough to connect to the
Ion Bar.
II.
Locate and attach the Ion Bar in a position so that
the air ions are directed toward the target area.
High Voltage
Out
Power Cable
Power Switch
III. Connect clean dry compressed air or gas to bar
air fitting.
Figure 1. SPI 94240 Controller LED and Control Functions
IV. Connect the Ion Bar to back of controller console.
V.
Plug the console unit into an appropriate electrical
outlet.
DESCRIPTION
The Linear Ion Bar Systems have been designed to
effectively eliminate localized static charges which exist
in the work area.
UNPACKING AND INSPECTION
Your controller and bars were carefully packed at the
factory in a container designed to protect it from
accidental damage. Nevertheless, we recommend
careful examination of the carton and contents for any
damage. If damage is evident, do not destroy the carton
or packing material. Immediately notify the carrier of a
possible damage claim. Shipping claims must be made
by the consignee to the delivering carrier.
The Air-Assisted Ion Bars are available in several sizes.
There are 4 Controller options, and several accessory
items. See the following table for the list of available
item numbers.
NOTES:
1. To connect your air or gas to the Air-Assisted Ion Bar,
supply the air/gas to the bar in a 1/4" flexible plastic
tube, inserting the tube into the red collar air fitting
already installed into one end of the Ion Bar. Be sure to
insert the tube snugly into red collar fitting and that it is
deeply seated. To remove the 1/4" air supply tubing,
simply depress the red collar, push in the tube and then
remove.
2. One SPI controller will power up to 40 emitters. It is
possible to daisy-chain bars together as long as the total
number of emitters does not exceed 40.
3. To permit the power supply console unit to supply
more than 1 Ion Bar, you must obtain and attach a
94250 two to one connector for two bars.
ESD Systems.com • 432 Northboro Road Central • Marlboro, MA 01752 • (508) 485-7390 • Fax (508) 480-0257 • Website: ESDSystems.com
TB-5521
December 2008 Page 1 of 3
© 2008 DESCO INDUSTRIES INC.
Employee Owned
HOW TO USE THE CONTROLLER
There are two adjustments that can be made on the
controller: BALANCE and RATE.
The BALANCE of positive and negative ion output can
be adjusted to increase polarity bias by turning the
BALANCE KNOB, and slowly turning the trim pot
CLOCKWISE to increase positive and decrease
negative ON time pulses OR COUNTER-CLOCKWISE
to increase negative and decrease positive ON time
pulses. The RATE or pulse frequency can be adjusted
down to one pulse per second or up to 5 pulses per
second by SLOWLY TURNING THE RATE KNOB trim
pot clockwise to increase and counter clockwise to
decrease the frequency.
REMEMBER:
It is important to verify calibration after any adjustments
and before using your ionizer around sensitive
electronics. Merely repeat above Balance Verification
steps after all adjustments.
IMPORTANT:
Your IONIZER has been designed to minimize effects of
localized static charges. If your processing involves
generation of considerable static charges you may
need more aggressive equipment. SPI has available a
complete line of ionizers; bench top, overhead and hand
ion guns to meet all ionizing requirements.
ION BAR SIZES AND DIMENSIONS
Refer to the following table and figure to learn more
about the dimensions of the Air-Assisted Ion Bars.
Figure 2. SPI Air-Assisted Ion Bar dimensions
Item # Length Emitters Mounting Dim A
94220
12"
4
2
1"
94221
24"
8
2
1"
94222
36"
12
2
3"
94223
48"
16
2
3"
94224
60"
20
2
3"
94225
72"
24
3*
4"
94226
96"
32
3*
4"
NOTE: Contact manufacturer for special dimensions
ESD Systems.com • 432 Northboro Road Central • Marlboro, MA 01752 • (508) 485-7390 • Fax (508) 480-0257 • Website: ESDSystems.com
© 2008 DESCO INDUSTRIES INC.
Employee Owned
TB-5521
Page 2 of 3
DISCHARGE TIMES
Recommended air applied: nominal of 2-10 PSI and
max. of 15 PSI.
Measurements are taken with a charged plate monitor
below two consecutive emitters with external air applied
of 5 PSI (nominal).
Pulsing rate is adjustable from 1 to 20 Hz. This will need
to be customized depending on application requirement.
Limited Warranty
ESD Systems.com expressly warrants that for a period of one (1)
year from the date of purchase, our SPI Ion Bars will be free of
defects in material. Within the warranty period, the material will be
tested and replaced at our option, free of charge. Call Customer
Service at 508-485-7390 for a Return Material Authorization
(RMA) and proper shipping instructions and address. You should
include a copy of your original packing slip, invoice, or other proof
of purchase date. Any material under warranty should be shipped
prepaid to the ESD Systems.com factory. Warranty repairs will
take approximately one week.
Warranty Exclusions
THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF
ALL OTHER PRODUCT WARRANTIES, EXPRESSED AND
IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY
DISCLAIMED. The express warranty will not apply to defects or
damage due to accidents, neglect, misuse, alterations, operator
error, or failure to properly maintain, clean or repair products.
Limit of Liability
Electronic ionizers use high voltage corona discharge and should
not be used in or near flammable or explosive environments. In
no event will ESD Systems.com or any seller be responsible or
liable for any injury, loss or damage, direct or consequential,
arising out of the use of or the inability to use the product. Before
using, users shall determine the suitability of the product for their
intended use, and users assume all risk and liability whatsoever
in connection therewith.
Decay (1000 to 100V)
Controller set at
2 cycles/sec (Hz)
Controller set at
2 cycles/sec (Hz)
Controller set at
1 cycle/sec (Hz)
Controller set at
1 cycle/sec (Hz)
Distance
Average
time in sec.
<10
<4
<4
<2
18”
12”
18”
12”
Note:
This data applies to all sizes of the air assisted SPI ion
bars, and is intended to be used as a reference.
Values will vary with environment and particular
application settings.
6 1/8"
1 5/8"
5 1/4"
Unit Weight: 1.86 lbs.
Cable: 5' length
Figure 3. SPI 94240 Controller Dimensions
ESD Systems.com • 432 Northboro Road Central • Marlboro, MA 01752 • (508) 485-7390 • Fax (508) 480-0257 • Website: ESDSystems.com
TB-5521
Page 3 of 3
© 2008 DESCO INDUSTRIES INC.