Features
Unregulated
Converters
●
●
●
●
●
●
●
●
UL/CSA and EN-60950-1 Safety certified
EN-61010 for Test, Measurement and Lab Use
UL/CSA and EN-60601 for Medical Applications
6.4kVDC or 8kV Reinforced Isolation
Optional Continuous Short Circuit Protection
Efficiency to 88%
Space Saving „Skinny DIP“ Package
Very Low Isolation Capacitance
ECONOLINE
DC/DC-Converter
with 3 year Warranty
Description
Very high isolation in a small size are the main features of this miniature DIP24 converter,
ideal for highly sophisticated industrial, test and measurement and medical designs where
board space is at a premium.
Selection Guide
Part
Number
SIP 7
RV-xx3.3S
RV-xx05S
RV-xx09S
RV-xx12S
RV-xx15S
RV-xx3.3D
RV-xx05D
RV-xx09D
RV-xx12D
Reinforced
Isolation
(kVDC)
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
/R6.4 & /R8
Input
Voltage
(VDC)
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
Output
Voltage
(VDC)
3.3
5
9
12
15
±3.3
±5
±9
±12
Output
Current
(mA)
600
400
222
167
132
±300
±200
±111
±85
Efficiency
Std
(%)
70-78
76-80
78-85
78-85
78-88
70-78
75-82
76-84
78-86
Max
Capacitive
Load
(1)
3300µF
1200µF
1200µF
680µF
680µF
±1500µF
±470µF
±470µF
±220µF
2 Watt DIP24
Miniature
Single
&
Dual
Output
2011/65/EU
6/6
RoHS
E-314885
RV-xx15D
/R6.4 & /R8
3.3, 5, 12, 15, 24
±15
±66
78-86
±220µF
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g.
RV-0505S/P, RV-0505D/P
* add Suffix “/R6.4”or “/R8” for Reinforced Isolation, e.g.
RV-0505S/R6.4, RV-0505D/P/R8
EN-60950-1 Certified
EN-60601-1 Certified
UL/CSA 60950-1 Certified
UL-60601-1 Certified
EN-61010-1 Certified
IEC-60601-1 CB Report
For functional isolation, please refer to RV sereis datasheet
RV/R
±10%
±5%
1.2%/1% of Vin typ.
20% max.
15% max.
10% max.
200mVp-p max.
20kHz min. / 50kHz typ. / 85kHz max.
70% min. / 75% typ.
Output Power (%)
100
80
60
40
20
0
-40
0
50
100
150
Specifications
(
measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
(10% to 100% full load)
Output Ripple and Noise (20MHz limited)
Operating Frequency
Efficiency at Full Load
Minimum Load = 0%
Isolation Voltage
/R6.4
/R8
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
P-Suffix
Operating Temperature Range (free air convection)
Storage Temperature Range
3.3V output types
5V output type
9V, 12V, 15V, 24V output types
Derating-Graph
(Ambient Temperature)
Specifications valid for 10% minimum load only.
(tested for 1 second)
6400VDC
(rated for 1 minute**)
3200VAC / 60Hz
(tested for 1 second)
8000VDC
(rated for 1 minute**)
4000VAC / 60Hz
2pF min. / 12pF max.
15 GΩ min.
1 Second
Continuous
-40°C to +85°C (see Graph)
-55°C to +125°C
continuned on next page
Safe Operating Area
85
Operating Temperature °C
**Any data referred to in this datasheet are of indicative nature
and based on our practical experience only. For further details,
please refer to our Application Notes.
Refer to Application Notes
www.recom-power.com
REV: 3/2016
E-113
ECONOLINE
DC/DC-Converter
Specifications
(
measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Relative Humidity
Package Weight
Packing Quantity
MTBF (+25°C)
(+85°C)
RV/R
Series
95% RH
9g
15 pcs per Tube
using MIL-HDBK 217F
using MIL-HDBK 217F
Reinforced Types
Reinforced Types
Reinforced Types
Report: T1301251-313
1154 x 10
3
hours
168 x 10
3
hours
5.5 mm min.
5.5 mm min.
9.6 mm min.
EN 61010-1 : 2010
UL 60950-1 1st Edition
C22.2 No. 60950-1-03
Report: E314885-A4
Report: 2207629
Report: SPCLVD1310079-1
Report: CA-10168-A1-UL
UL60601-1 3rd Edition
CAN/CSA-22.2 No 601.1-M90
EN60950-1 : 2006
IEC/EN 60601-1 3rd Edition
}
Detailed Information see
Application Notes chapter "MTBF"
Reinforced Isolation
Transformer Creepage
Transformer Clearance
PCB Creepage & Clearance
Certifications
Measurement, Control and Laboratory Use Safety
CSA General Safety
UL/cUL Medical Safety
CSA Medical Safety
EN General Safety
EN Medical Safety
Notes
Note 1
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
Tolerance Envelope
RV /R
+10%
+6%
V Nom.
Typica
l
Load
Line
+5%
2.5%
5%
Output Voltage
10%
50%
100%
Output Load Current (%)
E-114
REV: 3/2016
www.recom-power.com
ECONOLINE
DC/DC-Converter
EMC Filter Suggestions for EN55022 Class A and B
RV/R
Series
EN55022 Class B
L1
C1
Input
+
C1
L1
470μH
WE 7447471471
470μH
WE 7447471471
C2
10μF
10μF
C3
2n2F 8kV
Vishay HGZ222MBP
2n5F 10kV
Vishay HGZ222MBP
+
C2
Output
RxxP2xx/R6.4
10μF
RxxP2xx/R8
10μF
C3
Package Style and Pinning (mm)
24 PIN DIP Miniature Package Style
2.54 x 11
14.40
24 23
Single & Dual Output
17 16 15 14 13
11.40
4.10
0.25
15.24
0.50±0.05
16.95 max.
RECOM
RV-0505D/R6.4
****
1 2
8 9 10 11 12
0.60
RV /R
2.2
Recommended Footprint Details
32.35
1 2
16.10
24 23
8 9 10 11 12
Bottom View
17 16 15 14 13
Top View
2.54
1.0ø+0.15/0
Pin Connections
Pin #
1
2
8, 9, 11, 14
10, 15
Pin Connections
Single
+Vin
-Vin
NC
-Vout
+Vout
NC
Pin #
1
2
8, 17
9, 11, 14,16, 23, 24
10 & 15
12, 13
NC = No Connection
Dual
+Vin
-Vin
-Vout
NC
Com
+Vout
2.54
12 & 13
16, 17, 23, 24
NC = No Connection
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
E-116
REV: 3/2016
www.recom-power.com