350W Slim Type with PFC Switching Power Supply
UHP-350
series
Bauar t gepruft
Sicherheit
egel ma ge
od
o s
be wac
g
www. tuv.com
ID 2000000000
GB4943
UL60950-1
EN60950-1
EN60335-1
IEC60950-1
■
Features
Slim Low profile (31mm)
Fanless design,350W convection
Withstand 300VAC surge input for 5 seconds
Built-in active PFC function
150% peak load capability(100ms)
-
30
~
+70
℃
working temperature
Protections: Short circuit / Overload /
Over voltage / Over temperature
DC OK active signal and redundant function(option)
Operating altitude up to 5000 meter (Note.5)
LED indicator for power on
3 years warranty
■
Applications
Industrial automation machinery
Industrial control system
Mechanical and electrical equipment
Electronic instruments, equipments
or apparatus
Household appliances
LED display
application
■
Description
UHP-350 series is a 350W single-output slim type power supply with 31mm of low profile design.
Adopting the full range 90~264VAC input, the entire series provides an output voltage line of 3.3V,
4.2V, 5V, 12V, 15V, 24V, 36V and 48V. In addition to the high efficiency up to 94%, that the whole
series operatesfrom -30
℃
~ 70
℃
under air convection without fan. UHP-350 has the complete
protection functions and 5G anti-vibration capability
;
It is complied with the international safety
regulations such as TUV EN60950-1, EN60335-1, UL60950-1 and GB4943. UHP-350 series
serves as a high performance power supply solution for various industrial applications.
■
Model Encoding
UHP - 350
- 5
Output Voltage
Blank
R
Rated
wattage
Series name
Type
Blank
R
Enclosed
Built-in DC OK active signal and redundant function.
Description
Note
In Stock
In Stock
File Name:UHP-350-SPEC 2018-09-13
350W Slim Type with PFC Switching Power Supply
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
(convection)
RIPPLE & NOISE
(max.)
OUTPUT
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME
(Typ.)
VOLTAGE RANGE
Note.4
Note.2
UHP-350
-15 UHP-350
24V
14.6A
350.4W
240mVp-p
22.8~25.2V
±1.0%
±0.3%
±0.5%
-24 UHP-350
36V
9.75A
351W
240mVp-p
34.2~37.8V
±1.0%
±0.3%
±0.5%
series
-48
UHP-350 -3.3 UHP-350 -4.2 UHP-350
3.3V
60A
198W
150mVp-p
3.2~3.5V
±2.0%
±0.5%
±1.0%
10ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
4.2V
60A
252W
150mVp-p
3.6~4.4V
±2.0%
±0.5%
±1.0%
5V
60A
300W
200mVp-p
4.5~5.5V
±2.0%
±0.5%
±1.0%
-5 UHP-350
12V
29.2A
350.4W
200mVp-p
11.4~12.6V
±1.0%
±0.3%
±0.5%
-12 UHP-350
15V
23.4A
351W
200mVp-p
14.3~15.8V
±1.0%
±0.3%
±0.5%
-36 UHP-350
48V
7.3A
350.4W
240mVp-p
VOLTAGE ADJ. RANGE
Note.3
45.6~50.4V
±1.0%
±0.3%
±0.5%
2000ms, 80ms/230VAC
3000ms, 80ms/115VAC at full load
10ms/115VAC
127 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR
(Typ.)
INPUT
EFFICIENCY
(Typ.)
AC CURRENT
(Typ.)
INRUSH CURRENT
(Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
DC OK SIGNAL(Optional)
FUNCTION
REDUNDANT(Optional)
WORKING TEMP.
WORKING HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
EMC
ISOLATION RESISTANCE
(Note.6)
PF
≥
0.94/230VAC PF
≥
0.98/115VAC at full load
88.5%
4A/115VAC
89%
2A/230VAC
60A/230VAC
90%
91%
92%
94%
94%
94%
Cold start 30A/115VAC
<0.75mA / 240VAC
110~140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
3.8 ~ 4.6V
4.62 ~ 5.46V
5.75 ~ 6.75V 13.2 ~ 15.6V
16.5 ~ 19.5V
26.4 ~ 31.2V
39.6 ~46.8V
52.8 ~ 62.4V
Protection type :Shut down O/P voltage,re-power on to recover
Protection type :Shut down O/P voltage, recovers automatically after temperature goes down
Contact rating(max.):15Vdc/10mA resistive load
For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be
automatically enabled. This can prevent the system crash, and provide the reliability of system
-30 ~ +70
℃
(Refer to “Derating Curve")
20 ~ 90% RH non-condensing
±
0.03%/
℃
(0 ~ 50
℃)
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1,TUV EN60950-1,EN60335-1,CCC GB4943, EAC TP TC 004 approved,Design refer to EN61558-1,-2-16
I/P-O/P:3.75KVAC
I/P-FG:2KVAC
O/P-FG:1.25KVAC
I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25
℃
/ 70%RH
Compliance to EN55032,GB9254,Class B, EN55014,EN61000-3-2,-3,EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11;EN61000-6-2 (EN50082-2), heavy industry level ,criterial A,EAC TP TC 020
285 K hrs min.
MIL-HDBK-217F (25
℃
)
ENVIRONMENT STORAGE TEMP., HUMIDITY
-40 ~ +85
℃
, 10 ~ 95% RH non-condensing
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS DIMENSION
PACKING
NOTE
220*62*31mm (L*W*H)
0.68 kg;16 pcs/11.88 kg/0.63CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25
℃
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance :
includes set up tolerance,
line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the
derating curve
for more details.
5. The ambient temperature derating of 3.5
℃
/1000m with fanless models and of 5
℃
/1000m with fan models for operating altitude higher than 2000m(6500ft)
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
File Name:UHP-350-SPEC 2018-09-13