POWER
Data Sheet
Total Power:
600 W
# of Outputs:
Single
Outputs:
12, 28, 36, 48 Vdc
SPECIAL FEATURES
600 W full power at elevated
temperatures
Wide operating temperature range
(-40 °C to 85 °C baseplate)
Adjustable output
Remote output On/Off
AC_OK; DC_OK signals
5 V standby voltage
Active current share
Conduction-cooled/fanless
I
2
C / PMBus
Medical and ITE Safety
3
Suited for BF-type applications
Active power factor correction
Optional IP65 variant
Optional 277 Vac input variant
600 Watts Conduction Cooling
LCC600
Electrical Specifications
Input
Input range
U Suffix:
H Suffix:
Frequency
Input fusing
EMI/RFI
MIL-STD-461F EMI
1
Inrush current
Power factor
Harmonics
Input current
Hold up time
Efficiency
Leakage current
3
90 - 264 Vac (Safety rating:100 - 240 Vac)
127 - 374 Vdc
4
180 - 305 Vac (Safety rating: 200 - 277 Vac)
254 - 420 Vdc
4
47 - 63 / 440 Hz (Safety rating: 50/60 Hz)
Internal fuse on both L and N lines (12.5 A - U suffix; 7 A - H suffix)
FCC Class B, CISPR22/EN55022 Class B
Compliance to CE101, 102; CS101, 114, 115, 116 (with external filter
1
)
≤ 25 A peak
0.99 typical
Meets EN61000-3-2 Class A and Class C
2
< 10 Arms @ 100 Vac
20 ms min for Main Output (230 Vac) @ 100% Load
93.3% typical @ 230 Vac; 100% Load; 28 Vdc
U Suffix:
H Suffix:
115 µA typical (< 200 µA max per ANSI/ES60601-1 264 Vac
split-phase / 60 Hz)
387 µA typical (< 500 µA max per IEC60601-1; 264 Vac / 50Hz)
0.2 mA typical (< 3.5 mA max per ITE 60950-1 Standard)
U Suffix
4,000 Vac (2X MOPP)
1,500 Vac (1X MOPP)
1,500 Vac (1X MOPP)
H Suffix
3,000 Vac
2,000 Vac
1,500 Vac
COMPLIANCE
EMI Class B
EN61000 Immunity
SAFETY
UL + CSA:
60950-1 2
nd
Ed.
ANSI ES60601-1
3
UL 8750
5
CSA-C22.2 No. 250.13
5
TÜV:
60950-1 2
nd
Ed.
60601-1 3
rd
Ed.
3
EN 61347-1; -2-13
5
CB Scheme: IEC 60950-1
IEC 60601-1
IEC 61347-1; -2-13
5
China
CCC
CE Mark
Isolation voltage
PRI-SEC:
PRI-Chassis:
SEC-Chassis:
1
2
Artesyn Filter PN: 700-014447-0000 (Zhongguang PN: ZGLPG-10-02M).
Meets Class C ≥ 50% load.
3
U suffix have both ITE and Medical Safeties. H suffix carries ITE approval only.
4
DC input rating not part of product’s Safety approval.
5
LED Lighting approvals apply to all 48 V output variants.
LCC600 Data Sheet
Electrical Specifications
Output
Output rating
Standby output
Set point
Total regulation
Rated load
Minimum load
Output voltage adjust range
Output noise
Remote sense
Overcurrent protection
See Ordering Information table
5.0 Vdc @ 1.5 A Max
± 0.5%
Main Output: ± 2.0%
5 Vsb: ± 5%
600 W maximum
0A
See Ordering Information table
Main Output: 1.0% max p-p
5 Vsb: 60 mV max p-p
Compensation up to 500 mV
105 - 130% of full load current
Factory set point
Combined Line / Load / Temperature
600 W from -40 °C to 85 °C Baseplate Temp. Derate output
to 28 W @ 95 °C Baseplate Temp
For both Main and 5 Vsb Outputs
Max power limited to 600 W
Measured with 0.1 μF Ceramic and 10 μF Tantalum Cap,
20 MHz BW
Pin 10: +Vout_RS / Pin4: -Vout_RS
Default is Shutdown mode with Auto-retry every 2~4 sec.
Output latches after 20 sec of continuous OCP fault
presence. Restart after latch possible through AC recycle,
Inhibit toggle or through PMBus.
Latching / AC Recyle or Inhibit toggle required for PSU
restart
Output Shutdown / Auto-recovery
Active low when AC is present
Active low when Main Output is within regulation
Pin 19: Open/Float = ON; Close/Ground = OFF
Pin 5: IShare pin for main output only.
Consult with productsupport.ep@artesyn.com
Overvoltage protection
Overtemperature protection
AC_OK
DC_OK
Remote inhibit
# Units in parallel operation
Output dimming
125 - 145% Vo, nom Main Output
125 - 130% 5 Vsb
> 95 °C Baseplate temperature
Open Collector; 0.8 Vdc max / 10 mA
Open Collector; 0.8 Vdc max / 10 mA
Contact Closure
Qualified up to 5 units in parallel. Consult factory if
more than 5 are required.
0-10 Vdc external voltage;
0-100 kOhm external resistance
Environmental Specifications
Operating temperature range
Storage temperature
Humidity
Altitude
Shock
Vibration
Ingress protection
MTBF (calculated)
Electromagnetic immunity
-40 °C to +85 °C Baseplate temperature
-40 °C to +85 °C
10% to 95%
16,402 ft (Operating) / 50,000 ft (Non-Operating)
MIL-STD-810F 516.5 Procedure I, VI
MIL-STD-810F 514.5 Cat. 4, 10
IP65 (for suffix “-4P”)
>2M Hrs, 25 °C per SR-332 Issue 3
Designed to meet EN61000-4-3, -4, -5, -8, -11 (Level 3); EN61000-4-2 (Level 4); EN60601-1-2 and EN55024
For H suffix, Level 4 for EN61000-4-5
LCC600 Data Sheet
Ordering Information
Model Number*
AC Input
Output
Setpoint
Setpoint
Tolerance
Output Current [A]
Min
Max
Max O/P
Power [W]
Typical
Efficiency**
Standby Output
Combined
Line/Load
Regulation
Output
Ripple
LCC600-48U-4PD
(1)
LCC600-48U-9P
LCC600-48H-9P
LCC600-36U-9P
LCC600-36H-9P
LCC600-28U-9P24
LCC600-28U-9P
LCC600-28H-9P
LCC600-12U-9P
LCC600-12H-9P
90 - 264
90 - 264
180 - 305
90 - 264
180 - 305
90 - 264
90 - 264
180 - 305
90 - 264
180 - 305
54 V
48 V
±0.5%
±0.5%
0
0
11.1
12.5
600
600
93.0%
93.0%
5 Vdc @ 1.5 A
5 Vdc @ 1.5 A
2%
2%
1%
1%
36 V
24 V
28 V
±0.5%
±0.5%
±0.5%
0
0
0
16.7
25
25***
600
600
600
92.0%
93.0%
93.5%
5 Vdc @ 1.5 A
5 Vdc @ 1.5 A
5 Vdc @ 1.5 A
2%
2%
2%
1%
1%
1%
12 V
±0.5%
0
50
600
92.3%
5 Vdc @ 1.5 A
2%
1%
*Change suffix “-9P” to “-4P” for IP65 rated enclosure with fly lead wires
*Change suffix “-4P” to “-4PR” for IP65 rated enclosure with right angle fly lead wires (applies to 28, 36, 48 Vdc)
*Change suffix “-4P” to “-4PV” to omit the control cable (applies to 28, 36, 48 Vdc)
* Add suffix “CC” for Constant Current setting (e.g. “-4PCC”; “-9PCC”).
**Typical efficiency at high line, factory default voltage and full load
***When Vout is adjusted down to 24 V, the supply can deliver 25 A max (600 W max). At 28 V default output setting, max Iout is 21.43 A (600 W max).
(1)
“D” suffix for 0-10 Vdc analog external volatge dimming (11.1 A CC limit). Consult Technical Reference Notes for additional details.
Mechanical Drawings
228 0.50
-9P Suffix
4-POSITION TERMINAL BLOCK
M4x8 SCREW, 10mm PITCH
WITH PLASTIC COVER
(SEE NOTE 7)
SIGNAL PIN LOCATIONS
PIN 2
PIN 1
3-POSITION LOCKING CONNECTOR
(TYCO P/N: 1-350943-0 OR EQUIVALENT)
MATE WITH TYCO P/N: 350766-1 (HOUSING)
& 350536-1 (CONTACT TERMINAL)
TRIMPOT WINDOW
MODEL LABEL
HEADER CONNECTOR
(J1501)
MATE WITH P/N: JST PN PHDR-20VS (HOUSING)
& JST PN SPHD-001T-P0.5 (CONTAC PINS)
(SEE PIN LOCATION DETAILS)
PIN 20
PIN 19
228 0.50
(2.2)
85.0 0.50
(35.50)
(29.7)
0.20
101 0.50
73.34
73.34
40.66
Notes:
1) Recommended mounting screw is M4 in 6 locations; 8-10 kgf-cm torque.
2) Baseplate material/finish: 5 mm Aluminum with Black Anodized.
3) Weight: 9P Suffix: 1.63 kg typical
4P Suffix: 1.81 kg typical
4) Thermal hotspot reference is in the middle of the baseplate.
CUSTOMER MOUNTING HOLE
FIT WITH M4 SCREW
(6 PL)
93.00
39.8
-0.3
+0.7
LCC600 Data Sheet
Mechanical Drawings
-4P Suffix (28, 36, 48 Vdc)
(30)
300 10
SJTW 18AWGX3C
228 0.5
300 10
UL2517 14AWGX4C
(30)
UL2517 26AWGX20C+AL
MODEL LABEL
TRIMPOT LOCATION
228 0.5
290 10
39.8
-0.3
40.50max
+0.7
84.41 0.5
(21.4)
8.5
(50.5)
0.2
85 0.5
CUSTOMER MOUNTING HOLE 4.6
FIT WITH M4 SCREW
(6 PL)
101 0.5
CUT EXPOSED LEADS OF SIGNAL WIRES
(2-73.3)
(2-146.7)
(2-40.7)
-4P Suffix (12 Vdc)
300 10
HEIGHT MEASUREMENT
REFERENCE POINT
SEE NOTE 9
228 0.5
59 0.5
3X- 307
10
UL2517
26AWGX20C
TIN DIP
(3-93.0)
TIN DIP
ARTESYN P/N:
750-006769-000X
(INPUT CABLE ASSY)
46 0.5
ARTESYN P/N:
750-007030-00XX
(OUTPUT CABLE ASSY)
THW OR MTW
AWG 6 WIRE
RATING AND SAFETY LOGO LABEL
TRIMPOT LOCATION
85 0.50
(22)
(24)
(5)
(50.5)
0.2
CUSTOMER MOUNTING HOLE 4.6
FIT WITH M4 SCREW (SEE NOTE 8)
(6 PL)
101 0.50
(2X-146.7)
(2X-40.7)
(3X-93)
(2X-73.3)
LCC600 Data Sheet
Mechanical Drawings
-4PR Suffix (28, 36, 48 Vdc)
265.0 2.0
228 0.5
HEIGHT MEASUREMENT
REFERENCE POINT
40.5 MAX
45
45
300 10
300 10
MODEL
LABEL
TRIMPOT
LOCATION
80.1
101 0.5
UL2517 26AWGX20C+AL
UL2517 14AWGX4C
10
0.2
TIN DIP WIRES
0.2
SJTW 18AWGX3C
146.68
40.66
73.34
73.34
CUSTOMER MOUNTING HOLE 4.6
FIT WITH M4 SCREW
93 (3X)
30