EEWORLDEEWORLDEEWORLD

Part Number

Search

WM22-DINAV5DXA1

Description
Energy Management Power Analyzer with plug-in Output Modules
File Size257KB,10 Pages
ManufacturerETC
Download Datasheet View All

WM22-DINAV5DXA1 Overview

Energy Management Power Analyzer with plug-in Output Modules

Energy Management
Power Analyzer with plug-in Output Modules
Type WM22-DIN
Class 0.5 (current/voltage)
Three-phase power analyzer
Back-lighted LCD
4 x 3
1
/
2
DGT instantaneous variables read out
7
1
/
2
DGT energy read-out
Measurements of system and phase variables:
W, Wdmd, var, VA, VAdmd, PF (cosϕ), V, A, Hz, THD-A, THD-V
Measurements of total energies: kWh, kvarh
Measurements of partial energies: kWh, kvarh
Energy measurements according to EN61036 and EN61268
TRMS measurements of distorted wave forms
(voltages/currents)
Two basic models: direct connection 20(90)AAC,
CT 5(10)AAC and VT connection
Maximum value indication of W dmd and VA dmd (only
5A version); maximum value indication of A (only 90A
version)
Self power supply (available for some models only) or
auxiliary power supply: 24V, 48V, 115V, 230V, 50-60Hz;
18 to 60VDC, 77 to 143VDC
Degree of protection (front): IP 40
Front dimensions: 9 DIN modules
Analogue output by means of optional module
(20mA or 10VDC)
RS 422/485 Serial port by means of optional module
Alarm output by means of optional module
Dual pulse output by means of optional module
Control of phase asymmetry
Product description
Three-phase power analyzer
with built-in configuration
key-pad;
Particularly indicated for the
analysis of main, secondary
and energy metering electri-
cal variables.
Housing for DIN-rail or wall-
mounting, IP40 (front) pro-
tection degree.
Completely sealable housing.
In case of direct connection
up to 90A, the measuring
input terminals are suitable
for cables with a cross-sec-
tion area from 6 to 35 mm
2
.
The special design of the
instrument’s housing allows
to add at any time the inter-
face modules, even when
the instrument is already
installed.
The following modules are
available:
- for all versions: pulses out-
put;
- only for the versions with
auxiliary power supply:
analogue output, RS485
port or alarm output.
How to order
Model
Range code
System
Power supply
Slot A
Slot B
WM22-DIN AV5 3 X X XX
Important note:
The models from AV0 to AV7 can be equipped with any
type of available modules (slot A and B).
The models AV8 and AV9 can be equipped only with the
“O” and “R” type modules.
The AV8 and AV9 models can measure all the parameters even if
the three phase system being connected is missing one phase.
The Av2 model is suitable only for three-phase unbalanced sys-
tem without neutral.
Type selection
Range Code
Auxiliary Power Supply:
AV0:
208V
L-L
/20(90)AAC [3]
AV1:
400V
L-L
/20(90)AAC [1]
AV3:
660V
L-L
/20(90)AAC [2]
AV4:
208V
L-L
/5(10)AAC [3]
AV5:
400V
L-L
/5(10)AAC [1]
AV6:
100V
L-L
/5(10)AAC [3]
AV7:
660V
L-L
/5(10)AAC [2]
Self Power Supply:
AV2:
220V
L-L
/20(90)AAC [4]
AV8:
208V
L-L
/20(90)AAC [1]
AV9:
400V
L-L
/20(90)AAC [1]
System
3:
Three-phase,
unbalanced load with
or without neutral
Power supply
For all versions
A:
24VAC
-15+10%, 50-60Hz
B:
48VAC
-15+10%, 50-60Hz
C:
115VAC
-15+10%, 50-60Hz
D:
230VAC
-15+10%, 50-60Hz
4:
18 to 60VDC
5:
77 to 143VDC
AV2, AV8 and AV9 only
X:
Self Power Supply
400V
L-L
(-20+15%, 50-60Hz)
208V
L-L
(-20+15%, 50-60Hz)
220V
L-L
(-10+15%, 50-60Hz)
[3] Un: -20+20%
Slot A (retransmission)
X:
O:
None
AO2900 module
Dual open collector out-
put
Three operating modes:
two pulse outputs
(kWh and kvarh);
one alarm output
and one pulse
output (kWh or kvarh)
one output which is
remotely controlled
by a serial port
and one pulse
output (kWh or kvarh)
AO2910 module.
One relay output + one
open collector output.
Operation modes like
module AO2900.
Slot B (retransmission)
Only with A-B-C-D-4
power supply
XX:
None
A1:
AO2920 module
0-20mADC
analogue output
V1:
AO2921 module
0-10VDC
analogue output
S0:
AR2950 module
RS422/485
serial port
R:
[1] Un: -20+15%
[2] Un: -30+15%
[4] Un: -10 +15%
Specifications are subject to change without notice
WM22-DINDS1003
1

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号