For more information, please visit the
product page.
date
page
12/12/2017
1 of 10
SERIES:
VMS-200
│
DESCRIPTION:
AC-DC POWER SUPPLY
FEATURES
• compact 2 x 4” high power-density design (CNF version is 2.4 x 4.6”)
• universal input range
•
•
•
•
•
efficiencies up to 93.5%
4th edition medical safeties
fan output (+12 Vdc)
over voltage, over current, over temperature and short circuit protections
covered and open-frame configurations
TUVRheinland
www.tuv.com
ID xxxxxxxxxx
EN
60601-1
IEC
60601-1
MODEL
VMS-200-12
VMS-200-24
VMS-200-48
Notes:
1.
2.
3.
4.
output
voltage
(Vdc)
output
current
max
(A)
output
power
1
max
(W)
ripple
and noise
2
max
(mVp-p)
efficiency
3
typ
(%)
12
24
48
16.67
8.33
4.17
200
200
200
150
240
480
92
93.5
93
Maximum output power of 200 W with 10 CFM forced air or baseplate cooling, 180 W at 220 Vac with convection cooling.
At full load, nominal input, 20 MHz bandwidth oscilloscope, output terminated with 47 μF aluminum electrolytic and 0.1 μF ceramic capacitors.
At full load, 25°C, 230 Vac input.
All specifications are measured at Ta=25°C, nominal input voltage, and 75% rated output load unless otherwise specified.
PART NUMBER KEY
VMS-200
-
XX
-
XXX
Base Number
Output Voltage
Chassis:
“blank” = open-frame
CNF = covered
cui.com
For more information, please visit the
product page.
CUI Inc
│
SERIES:
VMS-200
│
DESCRIPTION:
AC-DC POWER SUPPLY
date
12/12/2017
│
page
2 of 10
INPUT
parameter
voltage
frequency
under voltage shutdown
current
inrush current
leakage current
leakage current (enclosure/
patient)
power factor correction
no load power consumption
meets EN 61000-3-2
0.3
W
at 100 Vac, full load
at 240 Vac, 25°C, cold start
at 264 Vac
conditions/description
min
90
47
69
typ
max
264
60
83
2.5
100
0.3
0.1
units
Vac
Hz
Vac
A
A
mA
mA
OUTPUT
parameter
output capacitance
initial set point accuracy
line regulation
load regulation
hold-up time
switching frequency
temperature coefficient
fan output
LED
open-frame: 12 Vdc / 300 mA
covered: 12 Vdc / 500 mA
indicates when power is on
conditions/description
at 115/230 Vac, full load
12 Vdc output models
24 Vdc output models
48 Vdc output models
at 60% load, 25°C
high line to low line at full load
at 60%±40% load
at 115 Vac
±2
±0.5
±1
10
85
±0.05
min
typ
max
16,400
8,570
1,270
units
μF
μF
μF
%
%
%
ms
kHz
%/°C
PROTECTIONS
parameter
over voltage protection
over current protection
short circuit protection
conditions/description
recycle ac input to restart
12 Vdc output models
24 Vdc ouput models
48 Vdc output models
hiccup, auto recovery
hiccup, auto recovery
130
min
typ
16
31
56
150
180
max
units
Vdc
Vdc
Vdc
%
SAFETY & COMPLIANCE
parameter
isolation voltage
isolation resistance
safety approvals
safety class
EMI/EMC
conducted disturbance
radiated disturbance
1
harmonic current emissions
Notes:
conditions/description
input to output for 1 minute
input to earth ground for 1 minute
output to earth ground for 1 minute
min
typ
max
4,000
1,500
1,500
units
Vac
Vac
Vac
MΩ
100
UL/cUL 60601-1 (3.1 edition), IEC 60601-1 (3.1 edition), EN 60601-1 (3.1 edition)
Class I & II
EN 60601-1-2 (4th edition)
EN 55011, FCC CFR 47 Part 18, Class B
EN 55011, FCC CFR 47 Part 18, Class B
IEC 61000-3-2:2014, Class A, Class D
1. Need an external 1 mH choke at input for Class II type to pass EN 55011 Class B.
cui.com
For more information, please visit the
product page.
CUI Inc
│
SERIES:
VMS-200
│
DESCRIPTION:
AC-DC POWER SUPPLY
date
12/12/2017
│
page
3 of 10
SAFETY & COMPLIANCE (CONTINUED)
parameter
voltage fluctuations & flicker
radio-frequency, continuous
radiated disturbance
electrical fast transient (EFT)
surge
conducted disturbances,
induced by RF fields
power frequency magnetic field
voltage dips
voltage interruptions
MTBF
RoHS
conditions/description
IEC 61000-3-3:2013, Criteria A
IEC 61000-4-3:2010, Criteria A
IEC 61000-4-4:2012, ±0.5 kV, ±1 kV, ±2 kV, Criteria A
IEC 61000-4-5:2014, L-N: ±0.5 kV, ±1 kV, L-PE, N-PE: ±0.5 kV, ±1 kV, ±2 kV, Criteria A
IEC 61000-4-6:2013, Criteria A
IEC 61000-4-8:2009, Criteria A
IEC 61000-4-11:2004, dip: 30% 500 ms, dip: 60% 100 ms, dip >95% 10 ms, Criteria A
IEC 61000-4-11:2004, >95% 5,000 ms, Criteria B
as per MIL-HDBK-217F, at full load, 25°C
2011/65/EU
279,000
hours
min
typ
max
units
ENVIRONMENTAL
parameter
operating temperature
storage temperature
operating humidity
storage humidity
non-condensing
non-condensing
conditions/description
see derating curves
min
-20
-40
typ
max
80
85
93
93
units
°C
°C
%
%
DERATING CURVES
VMS-200 Output Power vs. Input Voltage
(Natural Convection)
220
200
180
160
Load (W)
140
120
100
80
60
40
20
0
90
Load (W)
220
200
180
160
140
120
100
80
60
40
20
0
90
VMS-200-CNF Output Power vs. Input Voltage
(Natural Convection)
110
130
150
170
190
Input Voltage (Vac)
210
230
250
110
130
150
170
190
Input Voltage (Vac)
210
230
250
VMS-200 Output Power vs. Ambient Temperature
(Natural Convection)
200
180
160
Load (W)
140
120
100
80
60
40
20
0
-20
Input voltage 200~264 Vac
Input voltage 90~190 Vac
VMS-200-CNF Output Power vs. Ambient Temperature
(Natural Convection)
200
Input voltage 100~264 Vac
180
Input voltage 90 Vac
160
Load (W)
140
120
100
80
60
40
20
0
-20
-10
0
10 20 30 40 50 60
Ambient Temperature (°C)
70
80
-10
0
10 20 30 40 50 60
Ambient Temperature (°C)
70
80
cui.com
For more information, please visit the
product page.
CUI Inc
│
SERIES:
VMS-200
│
DESCRIPTION:
AC-DC POWER SUPPLY
date
12/12/2017
│
page
4 of 10
DERATING CURVES (CONTINUED)
100
VMS-200 Output Power vs. Ambient Temperature
(200W with 10 CFM air flow)
VMS-200-CNF Output Power vs. Ambient Temperature
(200W with 10 CFM air flow)
100
80
Load (%)
60
40
20
0
-20
80
Load (%)
60
40
20
0
-20
-10
0
10 20 30 40 50
Ambient Temperature (°C)
60
70
80
-10
0
10 20 30 40 50
Ambient Temperature (°C)
60
70
80
VMS-200 Output Power vs. Ambient Temperature
(at 115/230 Vac, baseplate cooling, natural convection)
250
200
Load (W)
VMS-200-CNF Output Power vs. Ambient Temperature
(at 115/230 Vac, baseplate cooling, natural convection)
250
200
Load (W)
150
100
50
0
-20
150
100
50
0
-20
-10
0
10 20 30 40 50
Ambient Temperature (°C)
60
70
80
-10
0
10 20 30 40 50
Ambient Temperature (°C)
60
70
80
EFFICIENCY CURVES
12 Vdc Output Efficiency Curve
(at 25°C)
95
90
Efficiency (%)
24 Vdc Output Efficiency Curve
(at 25°C)
95
90
Efficiency (%)
85
80
75
100
90 Vac
115 Vac
230 Vac
264 Vac
85
80
75
70
10
20
30
40
50
60
70
Current Load (%)
90 Vac
115 Vac
230 Vac
264 Vac
80
90
70
10
20
30
40
50
60
70
Current Load (%)
80
90
100
48 Vdc Output Efficiency Curve
(at 25°C)
95
90
Efficiency (%)
85
80
75
70
10
20
30
40
50
60
70
Current Load (%)
90 Vac
115 Vac
230 Vac
264 Vac
80
90
100
cui.com
For more information, please visit the
product page.
CUI Inc
│
SERIES:
VMS-200
│
DESCRIPTION:
AC-DC POWER SUPPLY
date
12/12/2017
│
page
5 of 10
MECHANICAL
parameter
dimensions
weight
cooling
CN1 input connector
output terminals
fan connector
conditions/description
min
typ
max
units
inch
inch
g
g
VMS-200 models: 4.000 x 2.000 x 1.480 (101.60 x 50.80 x 37.60 mm)
VMS-200-CNF models: 4.606 x 2.441 x 1.575 (117.00 x 62.00 x 40.00 mm)
VMS-200 models
VMS-200-CNF models
external fan or baseplate cooling
CN1 mates with JST housing VHR series, JST SVH-21/41T-P1.1
series crimp terminal or equivalent
+Vo & -Vo terminals are M3 screws
fan mates with JST housing PHR-R5500 series, JST R5503-PT
series crimp terminal or equivalent
253
314
MECHANICAL DRAWING
Open-frame
units: inch [mm]
tolerance: ±0.020 [±0.50]
CN1
PIN
1
2
3
FAN
PIN
1
2
Function
FAN V+
FAN V-
Function
ACL
-
ACN
4.000 101.60
3.701 94.00
PE
0.150 3.80
PE
0.150 3.80
1.701 43.20
ACN
ACL
13
0.
2
3.
0
-Vo
PE
Air flow
4-
10CFM
10mm
direction
FAN V+
FAN V-
LED
1.220 31.00 max
0.197 5.00 max
cui.com
1.480 37.60
2.000 50.80
+Vo