EEWORLDEEWORLDEEWORLD

Part Number

Search

9GV0412G3011

Description
DC AXIAL FAN 40X40X28MM TACH
CategoryThermal management products   
File Size131KB,2 Pages
ManufacturerSANYO
Websitehttp://www.semic.sanyo.co.jp/english/index-e.html
Download Datasheet Parametric Compare View All

9GV0412G3011 Online Shopping

Suppliers Part Number Price MOQ In stock  
9GV0412G3011 - - View Buy Now

9GV0412G3011 Overview

DC AXIAL FAN 40X40X28MM TACH

9GV0412G3011 Parametric

Parameter NameAttribute value
Voltage - Rated12VDC
size/dimensionsSquare - 40mm long x 40mm high
width28.00mm
airflow21.1 CFM(0.591m³/min)
static pressure1.044 inches water column (260.0 Pa)
Bearing typeball
Fan typeTube shaft type
characteristicRotor lock protection, speed sensor (tachometer)
noise52.0 dB(A)
Power (W)5.64W
RPM13000 RPM
Termination3 leads
Intrusion protection-
Operating temperature-4 ~ 140°F(-20 ~ 60°C)
ApprovalCSA,TUV,UL
Rated current0.470A
voltage range7 ~ 13.2VDC
Material - Frameplastic
Material - Bladeplastic
Service life at different temperatures40,000 hours at 60°C
San Ace 40 9GV
type
General Specifications
Material
…………………………………………
Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-0)
Expected life
……………………………………
See the table below. (L10 life: 90% survival rate for continuous operation in free air at 60˚C,
Motor protection function
…………………
Dielectric strength
……………………………
Insulation resistance
…………………………
Sound pressure level (SPL)
………………
Storage temperature
………………………
Lead wire
………………………………………
rated voltage)
Locked rotor burnout protection, Reverse polarity protection
For details, please refer to p. 529.
50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame)
10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame)
At 1 m away from the air inlet
-20 to +70˚C (Non-condensing)
Black or Blue
Sensor
Red
Mass
………………………………………………
50 g
Yellow
Specifications
The models listed below
have ribs and pulse sensors.
For models without ribs, append "1" to the end of model numbers.
Model no.
Rated voltage Operating voltage range Rated current Rated input
[V]
[V]
[A]
[W]
Rated speed
[min
-1
]
Max. airflow
[m³/min]
[CFM]
Max. static pressure
[Pa]
SPL
[dB (A)]
Operating temperature Expected life
[˚C]
[h]
9GV0412K301
9GV0412J301
9GV0412G301
9GV0412H301
9GV0412C301
10.8 to 12.6
12
7 to 13.2
0.84
0.6
0.47
0.31
0.15
10.08
7.2
5.64
3.72
1.8
16500
14700
13000
11600
8300
0.76
0.68
0.6
0.53
0.37
26.8
24.0
21.1
18.7
13.1
415
330
260
207
100
[inchH²O]
1.668
1.325
1.044
0.831
0.402
58
55
52
49
41
-
20 to
+
60
-
20 to
+
70
40000/60˚C
Other sensor specifications are available as options. Refer to the index (p. 554).
Airflow - Static Pressure Characteristics
9GV0412K301
With pulse sensor
9GV0412J301
With pulse sensor
9GV0412G301
With pulse sensor
Operating voltage range
(inch H
2
O) (Pa)
Operating voltage range
(inch H
2
O) (Pa)
Operating voltage range
(inch H
2
O) (Pa)
1.8
1.6
450
400
350
300
250
200
150
100
50
0
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
(m
3
/min)
5
12.6 V
1.75
1.50
450
400
300
250
200
150
100
50
0
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
(m
3
/min)
5
7V
13.2 V
12 V
1.50
400
350
300
250
200
150
100
50
0
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
(m
3
/min)
5
13.2 V
12 V
7V
Static
静圧
pressure
Static
静圧
pressure
1.2
1.0
0.8
0.6
0.4
0.2
0
12 V
10.8 V
1.25
1.00
0.75
0.50
0.25
0
Static
静圧
pressure
1.4
350
1.25
1.00
0.75
0.50
0.25
0
Airflow
風量
10 15
20
25
30
(CFM)
風量
Airflow
10
15
20
25
30
(CFM)
風量
Airflow
10
15
20
25
30
(CFM)
45
DC Fan 40 mm sq.
40
×
40
×
28
mm
DC
DC Fan

9GV0412G3011 Related Products

9GV0412G3011 9GV0412C301 9GV0412C3011 9GV0412H301 9GV0412H3011
Description DC AXIAL FAN 40X40X28MM TACH DC AXIAL FAN 40X40X28MM TACH DC AXIAL FAN 40X40X28MM TACH DC AXIAL FAN 40X40X28MM TACH DC AXIAL FAN 40X40X28MM TACH
Voltage - Rated 12VDC 12VDC 12VDC 12VDC 12VDC
size/dimensions Square - 40mm long x 40mm high Square - 40mm long x 40mm high Square - 40mm long x 40mm high Square - 40mm long x 40mm high Square - 40mm long x 40mm high
width 28.00mm 28.00mm 28.00mm 28.00mm 28.00mm
airflow 21.1 CFM(0.591m³/min) 13.1 CFM(0.367m³/min) 13.1 CFM(0.367m³/min) 18.7 CFM(0.524m³/min) 18.7 CFM(0.524m³/min)
static pressure 1.044 inches water column (260.0 Pa) 0.402 inches water column (100.1 Pa) 0.402 inches water column (100.1 Pa) 0.831 inches water column (207.0 Pa) 0.831 inches water column (207.0 Pa)
Bearing type ball ball ball ball ball
Fan type Tube shaft type Tube shaft type Tube shaft type Tube shaft type Tube shaft type
characteristic Rotor lock protection, speed sensor (tachometer) Rotor lock protection, speed sensor (tachometer) Rotor lock protection, speed sensor (tachometer) Rotor lock protection, speed sensor (tachometer) Rotor lock protection, speed sensor (tachometer)
noise 52.0 dB(A) 41.0 dB(A) 41.0 dB(A) 49.0 dB(A) 49.0 dB(A)
Power (W) 5.64W 1.8W 1.8W 3.72W 3.72W
RPM 13000 RPM 8300 RPM 8300 RPM 11600 RPM 11600 RPM
Termination 3 leads 3 leads 3 leads 3 leads 3 leads
Operating temperature -4 ~ 140°F(-20 ~ 60°C) -4 ~ 158°F (-20 ~ 70°C) -4 ~ 158°F (-20 ~ 70°C) -4 ~ 140°F(-20 ~ 60°C) -4 ~ 140°F(-20 ~ 60°C)
Approval CSA,TUV,UL CSA,TUV,UL CSA,TUV,UL CSA,TUV,UL CSA,TUV,UL
Rated current 0.470A 0.150A 0.150A 0.310A 0.310A
voltage range 7 ~ 13.2VDC 7 ~ 13.2VDC 7 ~ 13.2VDC 7 ~ 13.2VDC 7 ~ 13.2VDC
Material - Frame plastic plastic plastic plastic plastic
Material - Blade plastic plastic plastic plastic plastic
Service life at different temperatures 40,000 hours at 60°C 40,000 hours at 60°C 40,000 hours at 60°C 40,000 hours at 60°C 40,000 hours at 60°C

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号