EEWORLDEEWORLDEEWORLD

Part Number

Search

SDC320AS12-E

Description
AC/DC CONVERTER 12V 180W
CategoryPower/power management    The power supply circuit   
File Size772KB,4 Pages
ManufacturerXP Power
Websitehttps://www.xppower.com/
Environmental Compliance
Download Datasheet Parametric Compare View All

SDC320AS12-E Online Shopping

Suppliers Part Number Price MOQ In stock  
SDC320AS12-E - - View Buy Now

SDC320AS12-E Overview

AC/DC CONVERTER 12V 180W

SDC320AS12-E Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
package instruction,
Reach Compliance Codecompliant
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
CertificationCSA, EN, UL
Efficiency (main output)80%
high40.64 mm
Maximum input voltage264 V
Minimum input voltage180 V
length177.8 mm
Maximum grid adjustment rate0.5%
Maximum load regulation1%
Maximum operating temperature70 °C
Minimum operating temperature
Maximum output current26.67 A
Nominal output voltage12 V
ProtectOUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE; THERMAL
Maximum total power output320 W
width101.6 mm
Base Number Matches1
AC-DC
320 Watts
SDC Series
High Power Density
Single & Dual Outputs
Up to 700 W Peak Power
Fan Fail & Power Good Signals
Low Leakage Current Option
Fits 1U Applications
3 Year Warranty
xppower.com
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
90-132 VAC/180-264 VAC
47-63 Hz
7 A at 90 VAC, 3 A at 230 VAC
Max 70 A at 230 VAC, 35 A at 115 VAC,
cold start
Power Factor
• EN61000-3-2 class A
Earth Leakage Current
• <500 µA at 264 VAC/50 Hz
Input Protection
• T8 A/250 V fuse
General
Efficiency
Isolation
Switching Frequency
Power Density
Signals
MTBF
• Single output: 5 V: 70%,12 V: 80%,
All other models: >83% at 230 V & full load,
Dual Output: >70% at 230 V & full load
• 3000 VAC Input to Output, 1500 VAC Input
to Ground, 250 VDC Output to Ground
• 23 kHz typical single output models,
25 kHz typical dual output models
• 8.9 W/In
3
• Fan Fail & Power Good
• >100 kHrs to MIL-HDBK-217F,
at 25 °C GB
Output
• See tables
• ±5% on V1 (V2 of dual output models will
track by same % of adjustment)
Initial Set Accuracy
• ±1%
Minimum Load
• 1% on single output models,
10% on both output of dual output models
in order to maintain ripple & noise and
regulation specifications
Start Up Delay
• 1.5 s max at 120 VAC
Start Up Rise Time
• 50 ms typical
Hold Up Time
• 20 ms min at 80% of full load
Line Regulation
• ±0.5%
Load Regulation
• ±1% 1-100% load for single outputs,
±3% V1, ±7% V2 for dual outputs
(except AD0548 version: ±11% on V2)
Over/Undershoot
• 5% max
Transient Response
• ±5% max deviation, recovery to within
1% in 500 µs for a 50% load change
Ripple & Noise
• 1% pk-pk (see note 3)
Overvoltage Protection
• <130% on V1 recycle AC input to reset
Overtemperature
• Measured internally auto recovery
Overload Protection
• 110-140%
Short Circuit Protection
• Trip & restart, auto recovery
Fan Supply
• 12 V/300 mA, not available on
‘-F’ & ‘-E’ versions with built-in fans
Output Voltage
Output Voltage Trim
Environmental
Operating Temperature
• 0 °C to +70 °C, derate at 2.5%/°C from
+50 °C to +70 °C when force air cooled.
0 °C to +60 °C, derate at 5%/°C from
+50 °C to +60 °C when convection cooled.
Storage Temperature
• -20 °C to +85 °C
Operating Humidity
• 5-90%, non-condensing
Cooling
• ‘-F’ & ‘-E’ versions have built-in fans, 5 V
single output model requires 22 CFM to
meet forced air ratings, all other models
require 18 CFM.
Operating Altitude
• 3000 m
Vibration
• 5-50 Hz, acceleration 7.35 ms
2
on 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
EN55022 Level B conducted & radiated
EN61000-3-2 class A
EN61000-3-3
EN61000-4-2, level 3 Perf Criteria A
EN61000-4-3, 3 V/m Perf Criteria A
EN61000-4-4, level 2 Perf Criteria A
EN61000-4-5, installation class 3
Perf Criteria A
• EN61000-4-6, 3V Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
• UL60950-1, CSA C22.2 No. 60950-1,
EN60950-1

SDC320AS12-E Related Products

SDC320AS12-E SDC320AS24-E SDC320AS48-E
Description AC/DC CONVERTER 12V 180W AC/DC CONVERTER 24V 180W AC/DC CONVERTER 48V 180W
type - closed closed
Number of outputs - 1 1
Voltage - Output 1 - 24V 48V
Current - Output (maximum) - 7.5A 3.75A
Power (W) - 180W (320W forced air cooling) 180W (320W forced air cooling)
application - ITE (Business) ITE (Business)
Voltage - Isolation - 3000V 3000V
efficiency - 83% 83%
Operating temperature - 0°C ~ 70°C (with derating) 0°C ~ 70°C (with derating)
Installation type - Base installation Base installation
size/dimensions - 7.00" long x 4.00" wide x 1.60" high (177.8mm x 101.6mm x 40.6mm) 7.00" long x 4.00" wide x 1.60" high (177.8mm x 101.6mm x 40.6mm)
Minimum load required - yes yes

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号