BROADCASTING INDUSTRY
RE-RELA
20.2
.795
11.2
.441
8.9
.350
FEATURES
• Excellent high frequency characteris-
tics (Impedance 75Ω)
11.2
.441
9.6
.378
• Surface-mount terminal typ
available
20.2
.795
Frequency
V.S.W.R.
(Max.)
Insertion loss
(dB, Max.)
Isolation
(dB, Min.)
900MHz
1.2
0.2
60
2.6GHz
1.5
0.5
30
mm
inch
SPECIFICATIONS
Contact
Arrangement
Contact material
Initial contact resistance
1 Form C
Gold
Max. 100mΩ
1W
(at 2.6 GHz, Impedance
75
Ω,
V.S.W.R. Max.1.5)
10mA 24V DC
(resistive load)
10W (at 2.6GHz,
Impedance 75
Ω,
V.S.W.R. Max.1.5)
30 V DC
0.5 A DC
Max. 1.2 (to 900MHz)
Max. 1.5 (to 2.6GHz)
Max. 0.2 (to 900MHz)
Max. 0.5 (to 2.6GHz)
Min. 60dB (to 900MHz)
Min. 30dB (to 2.6GHz)
10
6
3×10
5
Characteristics
Initial insulation resistance*
1
Between open contacts
Initial
Between contact and coil
breakdown
Between contact and
voltage*
2
ground terminal
Operate time*
3
(at 20°C)
Release time (without diode)*
3
(at 20°C)
Temperature rise (at 20°C)*
4
Functional*
5
Shock resistance
Destructive*
6
Functional*
7
Vibration resistance
Destructive
Conditions for operation,
transport and storage*
8
(Not freezing and condensing
at low temperature)
Unit weight
Remarks
Ambient
temp.
Humidity
Min. 100 MΩ (a
500 Vr
1,000 V
500 Vr
Contact rating
Rating
Contact carrying power
Max. switching voltage
Max. switching current
V.S.W.R.
High frequency
characteristics
Insertion loss
(Impedance
75Ω)
Isolation
Mechanical (at 180 cpm)
Expected life
(min. opera-
tions)
1W, 2.6GHz,
Impedance 75Ω,
V.S.W.R.
&
1.5
Electrical
10mA 24V DC
(resistive load)
(at 20cpm)
Max. 1
Max. 5
Max. 6
Min. 500 m/
Min. 1,000 m
10 to 55 Hz
amplitude o
10 to 55 Hz
amplitude o
–40°C to
–40°F to
5 to 85%
Approx. 5 g
3×10
5
Coil (at 20°C,
68°F)
Nominal operating power
200 mW
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage" sec
*
2
Detection current: 10mA
*
3
Nominal operating voltage applied to the coil, excluding contact bo
*
4
By resistive method, nominal voltage applied to the coil: Contact c
10W, at 2.6GHz, Impedance 75Ω, V.S.W.R.
&
1.5
*
5
Half-wave pulse of sine wave: 11ms, detection time: 10µs.
*
6
Half-wave pulse of sine wave: 6ms
*
7
Detection time: 10µs
*
8
Refer to 5. Conditions for operation, transport and storage mentio
TYPICAL APPLICATIONS
Broadcasting market
• Set Top Box (CS/BS tuner, CATV tuner)
• Multi-function TV
• Measuring instruments for broadcasting
ORDERING INFORMATION
Ex. ARE
1
3
Contact
arrangement
1: 1 Form C
Operating
function
Terminal shape
Coil voltage
(DC)
03: 3 V
4H: 4.5 V
06: 6 V
09: 9 V
12: 12 V
24: 24 V
Packing st
3: Single side Nil: Standard PC board
stable type
terminal
A: Surface-mount
terminal
Nil: Carton (PC bo
Tube (Surface
terminal)
Z: Tape and reel
(picked from 1
Note: Tape and reel packing symbol “-Z” is not marked on the relay.
“X type tape and reel packing (picked from 8/9/10/11/12/13/14-pin side) is also
Suffix “X” instead of “Z”.
400 pcs. in an inner package (tape and reel); 800 pcs. in an outer package
Standard
PC board
terminal
ARE1303
ARE134H
ARE1306
ARE1309
ARE1312
ARE1324
Surface-mount
terminal
ARE13A03
ARE13A4H
ARE13A06
ARE13A09
ARE13A12
ARE13A24
Nominal
voltage,
V DC
3
4.5
6
9
12
24
Pick-up voltage,
V DC (max.)
(initial)
2.25
3.375
4.5
6.75
9
18
Drop-out
voltage, V DC
(min.)(initial)
0.3
0.45
0.6
0.9
1.2
2.4
Coil resistance,
Ω
(±10%)
45
101
180
405
720
2,880
Nominal
operating current,
mA (±10%)
66.7
44.4
33.3
22.2
16.7
8.3
Nominal oper-
ating power,
mW
200
200
200
200
200
200
Max. allowa
voltage, V
3.3
4.95
6.6
9.9
13.2
26.4
DIMENSIONS
1. Standard PC board terminal
20.2
.795
Stand off
11.2
.441
Direction indication
mm
Schematic (Bottom view)
1
7
14 13 12 11 10 9 8
NC
COM
NO
(Deenergized condition)
8.6
.339
0.3
.012
2.54
.100
0.5
.020
3.0
.118
0.3
.012
(1.49)
(.059)
0.3
.012
(2.09)
(.082)
7.62
.300
General tolerance:
±0.3
±.012
2. Surface mount terminal
(0.7)
(.028)
20.2
.795
Schematic (Top view)
NC
COM
NO
13.2
±0.5
11.2
.520
±.020
.441
Direction indication
(1.3)
(.511)
8.6
.339
0.3
.012
2.54
.100
0.5
.020
(1.49)
(.059)
7.62
.300
(2.09)
(.082)
0.3
.012
0.3
.012
14 13 12 11 10 9 8
1
7
(Deenergized condition)
9.6
.378
General tolerance:
±0.3
±.012
REFERENCE DATA
1. High frequency characteristics
(Standard PC board terminal)
• V.S.W.R. characteristics
2.0
1.9
Insertion loss, dB
1.8
V.S.W.R.
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1
900MHz
Frequency
COM-NC
3GHz
COM-NO
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
900MHz
Frequency
3GHz
COM-NO
COM-NC
Isolation, dB
• Insertion loss characteristics
• Isolation characteristics
0
10
20
30
40
50
60
70
80
90
100
900MHz
Frequency
COM-NO
COM-NC
3
78
RE
NOTES
1. Coil operating power
Pure DC current should be applied to the
coil. The wave form should be rectangular.
If it includes ripple, the ripple factor should
be less than 5%.
However, check it with the actual circuit
since the characteristics may be slightly
different.
2. Cleaning
For automatic cleaning, the boiling meth-
od is recommended. Avoid ultrasonic
cleaning which subjects the relays to high
frequency vibrations, which may cause
the contacts to stick.
It is recommended that alcoholic solvents
be used.
3. Soldering
1) The soldering shall be performed under
following condition.
Max. 260°C
500°F
10s
Max. 350°C
662°F
3s
The affect of the PCB on the relay will dif-
fer depending on the type of PCB used.
Please verify the type of PCB to be used.
Soldering time: within 5s
2) In case of automatic soldering, the fol-
lowing conditions should be observed
(Surface-mount terminal)
(1) Position of measuring temperature
1.0mm
.039inch
B
A
(2) IR (infrared reflow) soldering method
A:
B:
T
5
T
4
T
3
T
2
T
1
t
1
T
1
=150°C
302°F
T
2
=160°C
320°F
T
3
=183°C
361°F
T
4
=245°C
473°F
T
5
=270°C
518°F
t
2
t
3
t
4
t
5
t
2
- t
1
= 80 to 120 s
t
5
- t
3
= 30 to 40 s
t
4
= 170 to 190 s
+0.1
+.004
1.5
−0
.059
−0
dia.
Relay polarity bar
4
.157
2.0
±0.15
.079
±.006
1.75
.069
0.4
.016
1.7
.067
R0.75
RE Relay 20.0
.030
.787
1.5
.059
Tape coming out direction
20.2 44
±0.3
±.012
20.75
.795 1.732
.817
40.4
1.591
13.85
.545
+0.2
10.6
−0.3
+.008
.417
−.012
2) Dimensions of plastic reel
A: Surface of PC board where relay is mounted.
B: Above the PC board surface.
21
±0.8
±.031
dia.
.827
dia.
80
±0.1
3.150
±.004
13
±0.2
dia.
.512
±.008
dia.
2.0
±0.5
.079
±.020
+0.2
44.4
−0
+.008
1.748
−0
Max. 50.5
1.988
380
±0.2
±.008
14.961
For Cautions for Use, see Relay Technical Information (Page 48 to 76).
3/7/2002
79
All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.
Go To Online Catalog
,,,,,,,
,,,,,,,
,,,,,,,
,,,,,,,
,,,,,,,
85
Tolerance range
(Avoid freezing
when used at
temperatures
lower than
0°C32°F)
5
(Avoid
condensation
when used at
temperatures
higher than
0°C32°F)
–40
–40
0
+60
+32
+140
Temperature,
°C
°F
Temperature rise of relay itself may vary
according to the mounting level or the
heating method of reflow equipment.
Therefore, please set the temperature of
soldering portion of relay terminal and the
top surface of the relay case not to exceed
the above mentioned soldering condition.
It is recommended to check the tempera-
ture rise of each portion under actual
mounting condition before use.
4. Packing style
1) Tape dimensions
5. Conditions for operation, transport
and storage
1) Ambient temperature, humidity, and at-
mospheric pressure during usage, trans-
port, and storage of the relay:
(1) Temperature:
–40 to +60°C
–40 to +140°F
(2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the tem-
perature. Use within the range indicated
in the graph below.
(3) Atmospheric pressure: 86 to 106 kPa
Temperature and humidity range for us-
age, transport, and storage:
Humidity, %R.H.
2) Condensation
Condensation forms when there is a sud-
den change in temperature under high
temperature and high humidity conditions.
Condensation will cause deterioration of
the relay insulation.
3) Freezing
Condensation or other moisture may
freeze on the relay when the temperature
is lower than 0°C
32°F.
This causes prob-
lems such as sticking of movable parts or
operational time lags.
4) Low temperature, low humidity environ-
ments
The plastic becomes brittle if the relay is
exposed to a low temperature, low humid-
ity environment for long periods of time.