EEWORLDEEWORLDEEWORLD

Part Number

Search

2210-T210-K0M1-H131-4A

Description
Circuit Breakers 1077, 1P, DM, 277VAC/65VDC,M1, 1NC AUX, 4A
CategoryCircuit protection   
File Size319KB,6 Pages
ManufacturerE-T-A Circuit Breakers
Environmental Compliance
Download Datasheet Parametric View All

2210-T210-K0M1-H131-4A Online Shopping

Suppliers Part Number Price MOQ In stock  
2210-T210-K0M1-H131-4A - - View Buy Now

2210-T210-K0M1-H131-4A Overview

Circuit Breakers 1077, 1P, DM, 277VAC/65VDC,M1, 1NC AUX, 4A

2210-T210-K0M1-H131-4A Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerE-T-A Circuit Breakers
Product CategoryCircuit Breakers
RoHSDetails
Factory Pack Quantity1
Thermal-Magnetic Circuit Breaker 2210-T2...
Description
One, two and three pole thermal-magnetic circuit breakers with trip-free
mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934).
Featuring a combi-foot design for both symmetric and asymmetric rail
mounting. Available with auxiliary contact (1 x N/O or 1 x N/C) for status
signalling. Two and three pole models are internally linked to ensure that
both/all poles trip in the event of an overload on one pole, even if the
actuator is held in the ON position. This CBE can be supplied in current
ratings up to 32 A with a choice of characteristic curves. All screw
terminals are recessed for safety. Approved to CBE standard EN 60934
(IEC 60934).
Typical applications
Process control equipment, robotics, machine tool control,
communications systems, instrumentation.
1-pole
2210-T2..
1
3-pole
Technical data
For further details please see chapter: Technical Information
Voltage rating
AC 250 V; 3 AC 433 V (50/60 Hz); DC 65 V
(UL: AC 277/480 V; DC 65 V)
Current rating range
0.1...32 A for curves M1, T1
0.1...16 A for curves F1, F2
Auxiliary circuit
1 A, AC 240 V / DC 65 V, resistive
(min. 10 V / 10 mA)
Typical life
3 AC 433 V; AC 250 V: 0.1...25 A
10,000 operations at 1 x I
N
, inductive
DC 65 V:
0.1...32 A
10,000 operations at 1 x I
N
, inductive
3 AC 433 V; AC 250 V: 32 A
6,000 operations at 1 x I
N
, resistive
Ambient temperature
-30...+60 °C (-22...+140 °F) T 60
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664 A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
test voltage
operating area
AC 3,000 V
main/aux. circuit
AC 3,000 V
pole/pole
AC 1,500 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity I
cn
0.1...5 A
400 A
6...32 A
800 A
curves F1, F2, M1, T1: 0.1...16 A 2,500 A (at DC 32 V)
Interrupting capacity (UL 1077)
I
N
0.1...16 A
20...25 A
Preferred types
Preferred types
1-pole
2210-T210-K0M1-H121-
2-pole
2210-T220-K0M1-H221-
Standard current ratings (A)
0.5 1
x
x
2
x
3
x
4
x
5
x
6
x
8 10 16 20
x
x
x
x
0.5 1
2
x
3
4
x
5
6
x
8 10 16 20
x
x
x
Ordering information
Type No.
2210
single and multipole thermal-magnetic circuit breaker
Mounting
T
rail mounting
Actuator design
2
toggle
Number of poles
1
single pole protected
2
2-pole protected
3
3-pole protected
Accessories
0
without accessories
Terminal design (main contacts)
K0
screw terminals
Characteristic curve
F1
fast acting: therm.1.01-1.4xI
N
;
magn.2-4xI
N
DC (DC only)
F2
fast acting: therm.1.01-1.4xI
N
;
magn.3,5-6,5xI
N
AC/4,5-8,5xI
N
DC
M1
standard delay: therm. 1.01-1.4xI
N
;
magn. 6-12xI
N
AC, 7.8-15.6xI
N
DC
T1
delayed: therm. 1.01-1.4xI
N
; magn. 10-20xI
N
AC
Auxiliary contact design
H
without intermediate position
Auxiliary contacts
1
with auxiliary contacts
2
auxiliary contacts on pole 1 only
(multipole devices)
Auxiliary contact function (see diagrams)
2
1 N/O contact
3
1 N/C contact
Auxiliary contact - terminal design
1
screw terminals
Current ratings
0.1...32 A
2210 - T 2 1 0 - K0 M1- H 1 2 1 - 10 A
ordering example
AC 277 V
1-pole
AC 277/480 V
2-/3-pole
DC 65 V
Degree of protection
(IEC 60529/DIN 40050)
Vibration curves F1, F2:
curves M1, T1:
5,000 A
5,000 A
2,000 A
2,000 A
2,000 A
2,000 A
operating area IP30
terminal area IP20
3 g (57-500 Hz), ± 0.23 mm (10-57 Hz)
5 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
Shock
curves F1, F2: 25 g (11 ms), directions 1, 2, 3, 4, 5
10 g (11 ms), direction 6
curves M1, T1: 25 g (11 ms), directions 1, 2, 3, 4, 5
20 g (11 ms), direction 6
to IEC 60068-2-27, test Ea
Corrosion
96 hours at 5 % salt mist
to IEC 60068-2-11, test Ka
Humidity
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
Mass
approx. 60 g per pole
1812
www.e-t-a.de
1
Terminal software that supports automatic serial port search
Terminal S - a super simple serial terminal that supports automatic search of serial port numbers (Putty needs to find and enter the serial port number by itself).https://github.com/makerdiary/termina...
dcexpert MicroPython Open Source section
Last day! If you don't do this, your electric car will not be able to drive on the road
Electric bicycles have become the favorite of the general public for travel due to their lightness, flexibility and compactness. Whenever the rush hour comes, the unimpeded electric bicycles save many...
EEWORLD社区 TI Technology Forum
Why does the voltage meter always show 5?
#include reg52.h #define uint unsigned int #define uchar unsigned charuchar code LEDData[]= {0x3f,0x06,0x5b,0x4f,0x66,0x6d,0x7d,0x07,0x7f,0x6f }; sbit OE= P1^0; sbit EOC = P1^1; sbit ST= P1^2; sbit CL...
新晋电子发廋友 51mcu
RISC-V MCU Development (XI): Cross-core Engineering Conversion
Most embedded engineers use Keil for development, but Keil currently does not support RISC-V cores, only ARM cores. MounRiver Studio (MRS) supports both cores. In order to facilitate engineers to migr...
Moiiiiilter MCU
There is no spring that will not come
Today is the beginning of spring~~ Spring is here, everything will be fine~ May everyone be well!...
okhxyyo Talking
MPLAB X display issues
There are so many arrows and dots here, it's annoying, how can I remove them? Thanks!...
chenbingjy 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号