Part Number:
RSUF 12-256
Product Description
M23 Power Single-Ended Cordset: Male, straight, 12-pin, black body, 120 V AC/DC, 8 A; PUR black cable, 8x0.5 mm² + 3x1.0 mm²
Technical Specifications
Technical Data
Product Family:
Product Sub Family:
Brand:
Connector Type:
Type of Contact / Gender:
Connector Design:
Number of Pins:
Shielding:
Attachment Type:
Operating Voltage:
Rated Current:
Insulation Resistance:
Mating Cycles:
Ambient Temperature (Operation):
Protection Degree / IP Rating:
Pollution Degree:
Clearance / Creepage Distance:
Overvoltage Category:
Power Connector
M23 Power
Lumberg Automation
Cordset, single ended
male
straight
12
No
External thread fixed
120 V AC/DC
8A
˃ 10^9 Ohm
≤ 100
-25°C to +80°C
IP67
3 acc. to DIN EN 60664-1 (VDE 0110-1)
acc. to DIN EN 60664-1 (VDE 0110-1)
II acc. to DIN EN 60664-1 (VDE 0110-1)
Product Materials
Contact Base Material:
Contact Plating:
Contact Bearer Material:
Contact Bearer Color:
Flammability Class (Contact Bearer):
Molded Body Material:
Molded Body Color:
Flammability Class (Molded Body):
Attachment Material:
O-Ring Material:
CuZn
Cu/Au
PBT
white
UL 94 V0
TPU
black
UL 94-HB
CuZn, nickel-plated
FKM
Cable Data
Cable Number:
Conductor Size:
Number of Wires:
Minimal Bending Radius (Fixed Inst):
Minimal Bending Radius (Flexible Inst):
Cycles (Bending):
Conductor material:
256
8x0.5mm² + 3x1.0 mm²
11
˃5xD
˃ 10 x D
˃2M
Cu
Cable Jacket Material:
Cable Jacket Color:
Cable Diameter D:
Wire Insulation Material:
Insulated Wire Diameter:
PUR
black
Ø 9.30 ±0.20 mm
PP
8x Ø1.45 mm + 3x Ø1.95 mm
Ambient Temperature (Fixed Installation): -50°C to +80°C
Ambient Temperature (Flex Installation):
Ambient Temperature (Drag Chain Inst):
UL Cable Type:
Flammability Class (Cable Jacket):
-25°C to +80°C
-25°C to +60°C
AWM: 20549
DIN EN 60332-2-2, VDE 0482-332-2-2, IEC 60332-2-2, CSA FT-2; flame-retardant
Safety & Environmental Compliance
RoHS Compliant:
yes
Resistances
Halogenfree:
DIN EN 50267-2-1, IEC 60754-1, VDE 0482-267-2-1
Notes
Protection Degree / IP Rating Note:
Note Derating:
Note:
Particularities:
* only if mounted and locked in combination with Hirschmann / Lumberg connector.
* Notice derating
Do not connect / disconnect under load.
When the connector is unlocked and in risk of pollution the connector has to be covered with a protective cap ≥ IP54.
© 2018 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and
regulations based on their individual usage of the product.