3KW HIGH VOLTAGE POWER SUPPLY
HITEK POWER OL3000 SERIES
The HiTek Power OL3000 series range of single
output high voltage power supplies was designed as
a component power supply for use in a wide range of
diverse applications; from X-ray and general laboratory
systems, to heavy industrial use as typified by electron
beam welding and ion implantation. Designed using
the latest power switching IGBTs to ensure efficient
and reliable operation over the full operating range,
the OL3000 Series will give excellent performance
in the most severe of electrical environments.
®
PRODUCT HIGHLIGHTS
3kW of output power
Output voltages from 1kV to 60kV
Positive or Negative polarity to order
OEM version available
IGBT switch mode technology
Local or remote operation
CE Marked for EU LV Directive 73/23/EEC
©2018 Advanced Energy Industries, Inc.
HITEK POWER OL3000 SERIES
ELECTRICAL SPECIFICATIONS
Output Power
Output Voltage
Output Current
Input Voltage
Input Current
Polarity
Specification Range
Ripple
Recovery Time
Temperature Coefficient
Drift
Operating Temperature
Storage Temperature
Humidity
Altitude
Installation Category
Pollution Degree
Usage
Protection
Arc Count and Extinguish
3kW maximum at full rated output voltage and current
Units available with maximum output voltages from 1kV to 60kV
Up to 3A for 1kV and 50mA for 60kV, see table
208VAC ±10% (187VAC to 229VAC) 47-63Hz 3 phase plus protective earth
Less than 14A per phase
Positive or negative to order
Specifications apply above 5% of rated output voltage. The output can be controlled down to less than 0.25%
of rated output voltage.
Less than 0.1% of rated voltage +2V, peak to peak
Less than 500ms to within 0.1% of previous operating level following a short circuit or arc. Maximum overshoot
2% of rated output voltage
Less than 100ppm/°C
Less than 0.05% per hour after a 1 hour warm up, at constant load, line and temperature
0°C to +40°C
-20°C to +70°C
80% maximum relative humidity up to 31°C, reducing linearly to 50% at 40°C. Non-condensing (ref BS
EN61010-1)
Sea level up to 2000 metres (6500 feet)
II (BS EN61010-1)
2 (BS EN61010-1)
Indoor use only
The units are fully protected against over-temperature and overcurrent. Peak arc current is resistively limited.
Each time the ACE system detects an arc it blanks the supply off for a brief period to extinguish the arc. The
unit is then allowed to recover. If more arcs occur they are counted to determine the arc rate; if this exceeds a
safe level the power supply is shut down. The parameters are factory set to 25 arcs in any 5 second period.
Fan assisted, air is drawn in via side and rear panel vents and exits at the rear of the unit. Minimum airflow
required is 3m/s. Ambient air around the unit must not exceed 40°C.
The Series OL3000 meets the requirements of the Low Voltage Directive, 73/23/EEC, by complying with BS
EN61010-1:2001 when installed as a component part of compliant equipment. It is CE marked accordingly.
Equipment Class 1
EN55022 Class B for conducted and radiated emissions
EN61000-4-2 ESD - levels ±4kV contact, ±8kV air discharge
EN61000-4-4 Fast transients on mains input - levels ±2kV
EN61000-4-5 surges - levels ±2kV line to earth, ±1kV line to line
EN61000-4-8 magnetic fields - levels 30A/m at 50/60Hz
EN61000-4-11 voltage dips, interruptions
Cooling
Safety
Safety Class
EMC1
RoHS
The OL3000 is currently built to non-RoHS standard. This unit can, however, be configured to meet the
requirements of RoHS where significant customer demand requires it, although please note that this will have
an impact on delivery timescales.
1
The Series OL3000 is intended for installation as a component of a system and is designed to meetthese requirements.
The unit will not trip and recovers to normal operation after a disturbance as defined in SEMI F47-0706.
The EMC performance of the power supply can only be fully assessed when installed within, and as a part of, the final system.
2
advanced-energy.com
HITEK POWER OL3000 SERIES
ELECTRICAL SPECIFICATIONS (CONTINUED)
Voltage Regulation
Line
Load
Current Regulation
Line
Load
Less than 0.5% of rated current for a ±10% change in line voltage
Less than 0.5% of rated current for 0 to 100% change in output voltage
Less than 0.1% +0.5V change in output voltage for a 10% change in line voltage
Less than 0.1% +0.5V change in output voltage for 0 to 100% change in load current
advanced-energy.com
3
HITEK POWER OL3000 SERIES
MECHANICAL SPECIFICATIONS (CONTINUED)
Dimensions
Weight
See outline drawing and table below
Units up to and including 40kV: 27kg (60 lb)
Units over 40kV: 37kg (82 lb)
All connections are mounted on the rear panel
Series OL3000
Connections
Safety earth
HV output
Front panel
Mains
Harting Han GB
3kW HIGH VOLTAGE POWER SUPPLY
M6 stud
Proprietary coaxial connector, 2m cable provided
Stoving enamel trimite full gloss S60/6 colour cream R87177 as standard
3 PHASE
INPUT
M6 GROUND
STUD
HV O/P 3U VERSION
(SEE PLAN VIEW)
3.0 (0.1)
HV OUTPUT
3U VERSION
1.5 (0.06)
AIR IN
4 OFF SLOTS
7.1 x 10.3
(0.28 x 0.41)
mA METER
USER
INTERFACE
AIR
OUT
AIR
IN
429.8 (16.9) (OVER SIDE PLATES)
436.0 (17.2) (OVER SCREWS)
REAR VIEW
AIR IN
OUTPUT
VOLTAGE
UP TO 40kV
ABOVE 40kV
AIR IN
AIR OUT
559.0 (22.0)
PANEL HEIGHT
DIM. A
132.5 (5.2) 3U
221.6 (8.7) 5U
FIXING CENTRES
DIM. B
88.9 (3.5)
146.1 (5.8)
PLAN VIEW
482.6 (19.0)
8.8 (0.3)
=
465.0 (18.3)
I
O
HV OUTPUT
5U VERSION
368.3 (14.5)
153.5 (6.0)
SIDE VIEW
184.2 (7.3)
SLIDE MOUNTING (OPTIONAL)
M4 THREAD
58.3 (2.3)
Design developments may result in specification changes
A
HV ON
LOCAL
TRIP
Drawing dimensions are in mm (inches)
=
B
40.0 (1.6)
3.0 (0.1)
HV OFF REMOTE LIMIT
CIRCUIT
BREAKER
SEE DETAIL 'A'
10 TURN
VOLTAGE
ADJUST
FRONT VIEW
kV METER
10 TURN
CURRENT
ADJUST
DETAIL 'A'
DIMENSIONS ARE IN mm (Inches)
DRAWING SHOWS 3U VERSION.
4
w
advanced-energy.com
w w . h i t e k p o w e r . c o m
HITEK POWER OL3000 SERIES
3kW HIGH VOLTAGE POWER SUPPLY
Series OL3000
INTERFACE
All logical indicators are open collector outputs
Remote Control Interface Connections:
Remote Control Interface Connections:
The Series OL3000 is fitted with an analogue remote
The Series OL3000 is fitted with an analogue remote control interface,
rated at 16V (max) in the off state. An internal 100Ω
controlled via a 25-way female D-type connector:
female
resistor is connected in series with the open collector
control interface, controlled via a 25-way
transistor. The pull down voltage is 0.9V plus the
D-type connector:
internal resistor drop.
V STATUS INDICATOR
I STATUS INDICATOR
HV OUTPUT VOLTAGE MONITOR
TRIP INDICATOR
LOCAL INDICATOR
HV ON INDICATION
PROGRAM VOLTAGE MONITOR
HV ON Lo
HV ON Hi
PROGRAM VOLTAGE Hi
PROGRAM VOLTAGE Lo
0V
0V
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
HV OUTPUT CURRENT MONITOR
HV OFF INDICATOR
REMOTE INDICATOR
RESERVED
+10V REFERENCE VOLTAGE
RESERVED
RESERVED
ENABLE Lo
ENABLE Hi
CURRENT PROGRAM 0V
CURRENT PROGRAM
RESERVED
All analogue Voltage and Current Monitors are
0V to +10V ±0.5% ±20mV, with respect to pin 13,
representing 0 to rated output. Signal impedance
is less than 100Ω and minimum external load
resistance is 2kΩ.
All analogue Voltage and Current Inputs are 0V to
+10V on the Hi input with respect to the Lo input,
representing 0V to rated output ±0.2% of setting
±0.1% of rating. Input impedance is greater than 50kΩ.
All logical indicators are open collector outputs rated at 16V (max)
in the off state. An internal 100Ω resistor is connected in series with
the open collector transistor. The pull down voltage is 0.9V plus the
internal resistor drop.
All analogue Voltage and Current Monitors are 0V to +10V ±0.5%
±20mV, with respect to pin 13, representing 0 to rated output. Signal
impedance is less than 100Ω and minimum external load resistance is
2kΩ.
All analogue Voltage and Current Inputs are 0V to +10V on the Hi input
with respect to the Lo input, representing 0V to rated output ±0.2% of
setting ±0.1% of rating. Input impedance is greater than 50kΩ.
These component power supplies meet the requirements of EC Directive 73/23/EEC (LVD)
.
advanced-energy.com
5