74LVC2G04
Dual inverter
Rev. 10 — 22 May 2017
Product data sheet
1
General description
The 74LVC2G04 provides the dual inverting buffer.
Inputs can be driven from either 3.3 V or 5 V devices. These features allow the use of
these devices in a mixed 3.3 V and 5 V environment.
This device is fully specified for partial power-down applications using I
OFF
. The I
OFF
circuitry disables the output, preventing the damaging backflow current through the
device when it is powered down.
2
Features and benefits
•
•
•
•
Wide supply voltage range from 1.65 V to 5.5 V
5 V tolerant inputs for interfacing with 5 V logic
High noise immunity
Complies with JEDEC standard:
–
JESD8-7 (1.65 V to 1.95 V)
–
JESD8-5 (2.3 V to 2.7 V)
–
JESD8B/JESD36 (2.7 V to 3.6 V)
ESD protection:
–
HBM JESD22-A114F exceeds 2000 V
–
MM JESD22-A115-A exceeds 200 V
±24 mA output drive (V
CC
= 3.0 V)
CMOS low power consumption
Latch-up performance exceeds 250 mA
Direct interface with TTL levels
Inputs accept voltages up to 5 V
Multiple package options
Specified from −40 °C to +85 °C and −40 °C to +125 °C.
•
•
•
•
•
•
•
•
Nexperia
74LVC2G04
Dual inverter
3
Ordering information
Package
Temperature
range
Name
SC-88
SC-74
XSON6
XSON6
XSON6
XSON6
X2SON6
Table 1. Ordering information
Type number
Description
plastic surface-mounted package; 6 leads
plastic surface-mounted package (TSOP6); 6 leads
plastic extremely thin small outline package; no leads;
6 terminals; body 1 × 1.45 × 0.5 mm
plastic extremely thin small outline package; no leads;
6 terminals; body 1 × 1 × 0.5 mm
extremely thin small outline package; no leads;
6 terminals; body 0.9 × 1.0 × 0.35 mm
extremely thin small outline package; no leads;
6 terminals; body 1.0 × 1.0 × 0.35 mm
plastic thermal extremely thin small outline package;
no leads; 6 terminals; body 1 × 0.8 × 0.35 mm
Version
SOT363
SOT457
SOT886
SOT891
SOT1115
SOT1202
SOT1255
74LVC2G04GW
74LVC2G04GV
74LVC2G04GM
74LVC2G04GF
74LVC2G04GN
74LVC2G04GS
74LVC2G04GX
-40 °C to +125 °C
-40 °C to +125 °C
-40 °C to +125 °C
-40 °C to +125 °C
-40 °C to +125 °C
-40 °C to +125 °C
-40 °C to +125 °C
4
Marking
Marking code
V4
V04
V4
V4
V4
V4
V4
[1]
Table 2. Marking
Type number
74LVC2G04GW
74LVC2G04GV
74LVC2G04GM
74LVC2G04GF
74LVC2G04GN
74LVC2G04GS
74LVC2G04GX
[1]
The pin 1 indicator is located on the lower left corner of the device, below the marking code.
5
Functional diagram
1
3
1A
2A
1Y
2Y
mnb079
6
4
1
1
6
3
1
mnb080
4
A
Y
mna110
Figure 1. Logic symbol
Figure 2. IEC logic symbol
Figure 3. Logic diagram (one gate)
74LVC2G04
All information provided in this document is subject to legal disclaimers.
© Nexperia B.V. 2017. All rights reserved.
Product data sheet
Rev. 10 — 22 May 2017
2 / 19
Nexperia
74LVC2G04
Dual inverter
6
Pinning information
6.1 Pinning
74LVC2G04
74LVC2G04
1A
GND
2A
1
2
3
001aab649
1A
6
5
4
1Y
V
CC
1
6
1Y
GND
2
5
V
CC
2A
2Y
3
4
2Y
001aab650
Transparent top view
Figure 4. Pin configuration SOT363 and SOT457
74LVC2G04
1A
GND
2A
1
2
3
6
5
4
1Y
V
CC
2Y
Figure 5. Pin configuration SOT886
74LVC2G04
1A
1
GND
3
2A
2
5
4
2Y
1Y
6
V
CC
001aaf872
Transparent top view
aaa-019823
Figure 6. Pin configuration SOT891, SOT1115 and
SOT1202
Transparent top view
Figure 7. Pin configuration SOT1255 (X2SON6)
6.2 Pin description
Table 3. Pin description
Symbol
1A
GND
2A
2Y
V
CC
1Y
Pin
1
2
3
4
5
6
Description
data input
ground (0 V)
data input
data output
supply voltage
data output
74LVC2G04
All information provided in this document is subject to legal disclaimers.
© Nexperia B.V. 2017. All rights reserved.
Product data sheet
Rev. 10 — 22 May 2017
3 / 19
Nexperia
74LVC2G04
Dual inverter
7
Functional description
[1]
Table 4. Function table
Input
nA
L
H
[1]
H = HIGH voltage level; L = LOW voltage level.
Output
nY
H
L
8
Limiting values
Table 5. Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
Symbol Parameter
V
CC
I
IK
V
I
I
OK
V
O
I
O
I
CC
I
GND
P
tot
T
stg
[1]
[2]
[3]
Conditions
V
I
< 0 V
[1]
Min
-0.5
-50
-0.5
-
[1] [2]
[1] [2]
Max
+6.5
-
+6.5
±50
+6.5
±50
100
-
250
+150
Unit
V
mA
V
mA
V
mA
mA
mA
mW
°C
supply voltage
input clamping current
input voltage
output clamping current
output voltage
output current
supply current
ground current
total power dissipation
storage temperature
The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
When V
CC
= 0 V (Power-down mode), the output voltage can be 5.5 V in normal operation.
For SC-88 and SC-74 packages: above 87.5 °C the value of P
tot
derates linearly with 4.0 mW/K.
For X2SON6 and XSON6 packages: above 118 °C the value of P
tot
derates linearly with 7.8 mW/K.
V
O
> V
CC
or V
O
< 0 V
Active mode
Power-down mode
V
O
= 0 V to V
CC
-0.5
-0.5
-
-
-100
V
CC
+ 0.5 V
T
amb
= -40 °C to +125 °C
[3]
-
-65
74LVC2G04
All information provided in this document is subject to legal disclaimers.
© Nexperia B.V. 2017. All rights reserved.
Product data sheet
Rev. 10 — 22 May 2017
4 / 19
Nexperia
74LVC2G04
Dual inverter
9
Recommended operating conditions
Conditions
Min
1.65
0
Active mode
Power-down mode; V
CC
= 0 V
0
0
-40
V
CC
= 1.65 V to 2.7 V
V
CC
= 2.7 V to 5.5 V
-
-
Table 6. Recommended operating conditions
Symbol Parameter
V
CC
V
I
V
O
T
amb
Δt/ΔV
supply voltage
input voltage
output voltage
ambient temperature
input transition rise and fall rate
Typ
-
-
-
-
-
-
-
Max
5.5
5.5
V
CC
5.5
+125
20
10
Unit
V
V
V
V
°C
ns/V
ns/V
10 Static characteristics
Table 7. Static characteristics
At recommended operating conditions. Voltages are referenced to GND (ground = 0 V).
Symbol Parameter
V
IH
HIGH-level input
voltage
Conditions
V
CC
= 1.65 V to 1.95 V
V
CC
= 2.3 V to 2.7 V
V
CC
= 2.7 V to 3.6 V
V
CC
= 4.5 V to 5.5 V
-40 °C to +85 °C
Min
0.65V
CC
1.7
2.0
0.7V
CC
-
-
-
-
V
CC
- 0.1
1.2
1.9
2.2
2.3
3.8
-
-
-
-
-40 °C to +125 °C Unit
Min
0.65V
CC
1.7
2.0
0.7V
CC
-
-
-
-
V
CC
- 0.1
0.95
1.7
1.9
2.0
3.4
-
-
-
-
Typ
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
[1]
Max
-
-
-
-
0.35V
CC
0.7
0.8
0.3V
CC
-
-
-
-
-
-
0.10
0.45
0.30
0.40
Max
-
-
-
-
0.35V
CC
0.7
0.8
0.3V
CC
-
-
-
-
-
-
0.10
0.70
0.45
0.60
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
IL
LOW-level input
voltage
V
CC
= 1.65 V to 1.95 V
V
CC
= 2.3 V to 2.7 V
V
CC
= 2.7 V to 3.6 V
V
CC
= 4.5 V to 5.5 V
V
OH
HIGH-level
output voltage
V
I
= V
IH
or V
IL
I
O
= -100 μA;
V
CC
= 1.65 V to 5.5 V
I
O
= -4 mA; V
CC
= 1.65 V
I
O
= -8 mA; V
CC
= 2.3 V
I
O
= -12 mA; V
CC
= 2.7 V
I
O
= -24 mA; V
CC
= 3.0 V
I
O
= -32 mA; V
CC
= 4.5 V
V
OL
LOW-level output V
I
= V
IH
or V
IL
voltage
I
O
= 100 μA;
V
CC
= 1.65 V to 5.5 V
I
O
= 4 mA; V
CC
= 1.65 V
I
O
= 8 mA; V
CC
= 2.3 V
I
O
= 12 mA; V
CC
= 2.7 V
74LVC2G04
All information provided in this document is subject to legal disclaimers.
© Nexperia B.V. 2017. All rights reserved.
Product data sheet
Rev. 10 — 22 May 2017
5 / 19