https://www.phoenixcontact.com/hq/products/1525513
Bus system cable - SAC-2P-10,0-915/M12FSB - 1525513
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Bus system cable, PROFIBUS, 2-position, PUR/PVC, blue, shielded, free cable end, on Socket straight M12,
B-coded, Cable length: 10 m
Key Commercial Data
Packing unit
GTIN
GTIN
Custom tariff number
Note
4017918950170
85444290
Made to Order (non-returnable)
1 STK
Technical data
Dimensions
Length of cable
10 m
Ambient conditions
Ambient temperature (operation)
Degree of protection
-25 °C ... 90 °C (Plug / socket)
IP65
IP67
General
Rated current at 40°C
Rated voltage
Number of positions
Insulation resistance
Coding
Signal type/category
Status display
Overvoltage category
Degree of pollution
4A
100 V
2
≥ 100 MΩ
B - inverse
PROFIBUS
No
II
3
11/13/2016 Page 1 / 3
https://www.phoenixcontact.com/hq/products/1525513
Bus system cable - SAC-2P-10,0-915/M12FSB - 1525513
Technical data
General
Insertion/withdrawal cycles
Torque
≥ 100
0.4 Nm (M12 connector)
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Material of grip body
Material, knurls
Sealing material
V0
CuSn
Ni/Au
TPU GF
TPU, hardly inflammable, self-extinguishing
Zinc die-cast, nickel-plated
NBR
Pin assignment
Position = wire color (signal) = position (optional)
2 (Socket) = GN (A cable)
4 (Socket) = RD (B cable)
Standards and Regulations
Flammability rating according to UL 94
V0
Cable
Cable type
Cable type (abbreviation)
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Wire colors
Overall twist
Shielding
Optical shield covering
External sheath, color
Outer sheath thickness
External cable diameter D
Minimum bending radius, flexible installation
Number of bending cycles
Bending radius
Acceleration
Cable weight
Outer sheath, material
Material, inner sheath
Material conductor insulation
Conductor material
Insulation resistance
PROFIBUS
915
2x 0.25 mm²
24
19x 0.14 mm
2.56 mm
Red, green
2 wires, twisted
Aluminum-coated foil, tinned copper braided shield
70 %
blue
approx. 0.8 mm
8 mm ±0.4 mm
5xD
3000000
60 mm
4 m/s²
74 kg/km
PUR
PVC
Foamed PE
Bare Cu litz wires
≥ 16 GΩ*km
11/13/2016 Page 2 / 3
https://www.phoenixcontact.com/hq/products/1525513
Bus system cable - SAC-2P-10,0-915/M12FSB - 1525513
Technical data
Cable
Working capacitance
Nominal voltage, cable
Test voltage Core/Core
Flame resistance
Resistance to oil
Ambient temperature (operation)
28 nF (at 1 kHz)
≤ 100 V
3600 V DC
According to IEC 60332-1
Resistant to mineral oils and grease
-40 °C ... 80 °C
Drawings
Schematic diagram
3
4
Dimensional drawing
5
44,5
M12
GN
RD
Ø12
Pin assignment M12 socket, 5-pos., B-coded,
female side
M12 x 1 socket, straight, shielded
Circuit diagram
1
2
4
3
5
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
Ø15
2
1
11/13/2016 Page 3 / 3