EEWORLDEEWORLDEEWORLD

Part Number

Search

HDU60-B-20

Description
DC-DC CONVERTER 19 COMPATIBLE EUROCARD MULTIPLEV OUTPUT 45-100 WATTS SWITCHING MODE POWER SUPPLIES HDU45, HDU60 AND HDU100 SERIES
File Size354KB,4 Pages
ManufacturerTotal Power International
Websitehttp://www.total-power.com/
Download Datasheet View All

HDU60-B-20 Overview

DC-DC CONVERTER 19 COMPATIBLE EUROCARD MULTIPLEV OUTPUT 45-100 WATTS SWITCHING MODE POWER SUPPLIES HDU45, HDU60 AND HDU100 SERIES

DC-DC CONVERTER 19" COMPATIBLE EUROCARD MULTIPLE
OUTPUT 45-100 WATTS SWITCHING MODE POWER SUPPLIES
HDU45, HDU60 & HDU100 SERIES
FEATURES:
12/24/48VDC INPUT RANGE
19" COMPATIBLE EUROCARD FORMAT
EMI MEET CISPR PUB. 22 & FCC CLASS B
MEET THE SAFETY STANDARDS
CE MARKING COMPLIANCE
HDU45 3UX6HPX160MM VMEbus STANDARD
HDU60 3UX8HPX160MM VMEbus STANDARD
HDU100 3UX10HPX160MM VMEbus STANDARD
SPECIFICATION
INPUT SPECIFICATION
Input Voltage:
Three ranges option.
A Range: 9-18Vdc nominal 12Vdc.
B Range: 18-36Vdc nominal 24Vdc.
C Range: 36-72Vdc nominal 48Vdc.
Input Connector:
DIN 41612 at rear.
Input Current:
HDU45-A: 8.0A,HDU45-B: 4.0A,HDU45-C: 2.5A.
HDU60-A: 10.0A,HDU60-B: 5.0A,HDU60-C: 3.15A.
HDU100-A: 15.0A,HDU100-B: 6.3A,HDU100-C: 4.0A.
Dielectric Withstand:
Meet IEC950.
EMI:
Meet CISPR PUB. 22 & FCC Class B.
Power Fail Signal:
Installed.
Remote (Logic) Inhibit:
Installed.
Overload Protection (OLP):
Fully protected against
output overload and short circuit.
Consult the factory for OLP setting.
OUTPUT SPECIFICATION
Output Voltage:
See Ratings Chart.
Output Current:
See Ratings Chart.
Output Wattage:
Typ. 45 Watts for HDU45.
Typ. 60 Watts for HDU60.
Typ. 100 Watts for HDU100.
Output Connector:
DIN 41612 at rear.
Line Regulation:
Typ. 0.4%.
Load Regulation:
Main VO1 typ. ±1.0%.
Aux. VO2 typ. ±2-3.0%(PR).
± 2.0%(Mag. Amp.)
Aux. VO3 typ. ±2-3.0% (PR).
Aux. VO4 typ. ±2-3.0%(PR).
Noise & Ripple:
Typ. 1% peak to peak.
OVP:
Built-in at main VO1 (latch).
Adjustability:
Available at main output VO1 and
Aux. Output VO2 (Mag. Amp.).
Remote Sense:
Available at HDU60 & 100 single O/P.
Operating Temperature:
0 to +50°C at full load. Derates
linearly to +70°C at half load.
Storage Temperature:
-20 to +85°C.
Temperature Coefficient:
Typ. 0.04% /°C.
Cooling:
Free air convection.
Construction:
6,8,10 HP(TE)x3Ux160mm 19" compatible
Eurocard VMEbus standard.
GENERAL SPECIFICATION
Efficiency:
Typ. 70.0-75.0%
Switching Frequency:
Typ. 100K Hz.
Circuit Topology:
Forward circuit.
Transient Response:
Typ. 3mS following a 25%
load change.
Power Density:
1.4 Watts / Cubic Inch for HDU45, HDU60.
1.9 Watts /Cubic Inch for HDU100.
How to implement the 0-10V circuit of the inverter and motor speed control interface?
How to implement the 0-10V circuit of the inverter and motor speed control interface?How competitive is this GP9301/GP8101 solution?...
zjqmyron Motor Drive Control(Motor Control)
BLE over-the-air upgrade
TI CC2541 supports multiple hardware and software to perform air upgrades on it. There are different combinations of hardware.Currently available software includesIt is relatively easy to get the hard...
灞波儿奔 Wireless Connectivity
Schematic diagram of serial communication interface
Initialize the GPIO corresponding to the Tx and Rx pins of the serial port...
fish001 DSP and ARM Processors
go go go, make the LED of RSL10 start blinking (there is a little easter egg at the end of the article)
[i=s]This post was last edited by sunduoze on 2021-4-17 23:51[/i]Objective: Build a basic development environment to realize the Arduino interface RS10-002GEVB board onboard LED flashing Environment: ...
sunduoze onsemi and Avnet IoT Innovation Design Competition
Module Power Structure Design Guide
The main form of module power supply is DC-DC module, in addition there are AC-DC module, DC-AC (ring current) module. Unless otherwise specified, this article assumes DC-DC module....
鬼谷清泉 Power technology
【Help】ADC acquisition
I want to use DIO0, 1, 2, 3ADC to collect four voltage values Based on the routine peripheral_server_uart, the ADC configuration is changed The value read out now is 3FFF Is the configuration wrong?...
Aaaaaoooo onsemi and Avnet IoT Innovation Design Competition

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号