https://www.phoenixcontact.com/hq/products/1413762
Sensor/Actuator cable - SAC-4P-MS/ 7,0-240 SCO - 1413762
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/Actuator cable, 4-position, PUR halogen-free, yellow RAL 1021, Plug straight M12 SPEEDCON, A-
coded, on free cable end, Cable length: 7 m
As shown in the illustration but with
a yellow conductor
Key Commercial Data
Packing unit
Minimum order quantity
GTIN
GTIN
Custom tariff number
Note
4055626008493
85444290
Made to Order (non-returnable)
1 STK
50 STK
Technical data
Dimensions
Length of cable
Stripping length of the free conductor end
7m
50 mm
General
Rated current at 40°C
Rated voltage
Number of positions
Insulation resistance
Coding
Standards/regulations
Status display
Overvoltage category
Degree of pollution
Insertion/withdrawal cycles
4A
250 V
4
≥ 100 MΩ
A - standard
M12 connector IEC 61076-2-101
No
II
3
≥ 100
11/13/2016 Page 1 / 3
https://www.phoenixcontact.com/hq/products/1413762
Sensor/Actuator cable - SAC-4P-MS/ 7,0-240 SCO - 1413762
Technical data
Material
Flammability rating according to UL 94
Contact material
Contact surface material
Contact carrier material
Material of grip body
Material, knurls
HB
CuSn
Ni/Au
TPU GF
TPU, hardly inflammable, self-extinguishing
Zinc die-cast, nickel-plated
Standards and Regulations
Standard designation
Standards/regulations
Flammability rating according to UL 94
M12 connector
IEC 61076-2-101
HB
Cable
Cable type
Cable type (abbreviation)
Cable abbreviation
Conductor cross section
AWG signal line
Conductor structure signal line
Core diameter including insulation
Thickness, insulation
Wire colors
Overall twist
Length of twist, overall twist
External sheath, color
External cable diameter D
Smallest bending radius, fixed installation
Smallest bending radius, movable installation
Number of bending cycles
Bending radius
Traversing path
Traversing rate
Acceleration
Cable weight
Outer sheath, material
Material conductor insulation
Conductor material
Insulation resistance
Conductor resistance
Nominal voltage, cable
Test voltage, cable
PUR halogen-free yellow
240
Li9Y11Y
4x 0.34 mm²
22
42x 0.10 mm
1.27 mm ±0.02 mm
≥ 0.21 mm (Core insulation)
approx. 0.8 mm (Outer cable sheath)
brown, white, blue, black
4 wires, twisted
49.5 mm
yellow RAL 1021
4.7 mm ±0.15 mm
23.5 mm
47 mm
4000000
47 mm
10 m
3 m/s
10 m/s²
30 kg/km
PUR
PP
Bare Cu litz wires
≥ 1 GΩ*km (at 20 °C)
max. 58 Ω/km (at 20 °C)
≤ 300 V
≥ 3000 V
11/13/2016 Page 2 / 3
https://www.phoenixcontact.com/hq/products/1413762
Sensor/Actuator cable - SAC-4P-MS/ 7,0-240 SCO - 1413762
Technical data
Cable
Special properties
Flexible cable conduit capable
Silicone-free
Free of substances which would hinder coating with paint or varnish
Flame resistance
Halogen-free
Resistance to oil
Other resistance
Ambient temperature (operation)
in accordance with DIN UL-Style 20549
in accordance with FT1 as per UL 758
in accordance with DIN VDE 0472 part 815
in accordance with DIN EN 50267-2-1
in accordance with DIN EN 60811-2-1
Highly resistant to acids, alkaline solutions and solvents
hydrolysis and microbe resistant
-40 °C ... 80 °C (cable, fixed installation)
-25 °C ... 80 °C (cable, flexible installation)
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Drawings
Schematic diagram
4
3
Cable cross section
1
2
Pin assignment M12 plug, 4-pos., A-coded, view plug side
PUR halogen-free yellow [240]
Dimensional drawing
Circuit diagram
46,8
1
2
BN
WH
BK
BU
Ø14,8
M12
Ø11
4
3
M12 x 1 plug, straight
Contact assignment of the M12 plug
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
11/13/2016 Page 3 / 3