EEWORLDEEWORLDEEWORLD

Part Number

Search

AC6-OME2H-00-HG

Description
Switching Power Supplies 85-264VAC 120-350DC 650 W
CategoryPower/power management   
File Size283KB,7 Pages
ManufacturerCosel
Environmental Compliance
Download Datasheet Parametric View All

AC6-OME2H-00-HG Online Shopping

Suppliers Part Number Price MOQ In stock  
AC6-OME2H-00-HG - - View Buy Now

AC6-OME2H-00-HG Overview

Switching Power Supplies 85-264VAC 120-350DC 650 W

AC6-OME2H-00-HG Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerCosel
Product CategorySwitching Power Supplies
RoHSDetails
Output Voltage-Channel 124 VDC
Output Voltage-Channel 212 VDC
Number of Outputs3 Output
Output Power650 W
Open Frame/EnclosedEnclosed
Input Voltage85 VAC to 264 VAC/120 VDC to 350 VDC
Output Current-Channel 114 A
Output Current-Channel 213 A
IndustryCommercial
Isolation Voltage3 kVAC
Mounting StyleChassis
ApprovalsEN60950-1, UL60950-1
Output Current-Channel 310 A
Output Voltage-Channel 35 V
Factory Pack Quantity3
AC-DC Power Supplies Configurable type
Ordering information
ACE series
R
AC
O
-
OOOOOO
-
O O
-
O O
1
2
3
4
5
6
7
8
9
10
Recommended EMI/EMC Filter
ACE300F
NAC-06-472
ACE450F
NAC-10-472
ACE650F
NAC-20-472
ACE900F
NAC-20-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
1
Abbreviation type
name of ACE series
2
Abbreviation power
of ACE series
3 : ACE300F
4 : ACE450F
6 : ACE650F
9 : ACE900F
3
Slot 6 Output module
4
Slot 5 Output module
5
Slot 4 Output module
6
Slot 3 Output module
7
Slot 2 Output module
8
Slot 1 Output module
9
Parallel code
10
Option (series code)
*8
Refer to instruction manual 5.1
Safety : UL60601-1, EN60601-1
Refer to instruction
manual 7. for details.
6 5 4 3 2 1
*The
number of slot is
different depending on the
model.
*Empty
slot is code:0
Slot
SPECIFICATIONS
MODEL
VOLTAGE[V]
FREQUENCY[Hz]
AC100V
*1
CURRENT[A]
AC200V
*1
AC100V
*1
POWER FACTOR
AC200V
*1
INRUSH CURRENT AC100V
*2
[A]
AC200V
*2
AC100V
*1
EFFICIENCY[%]
AC200V
*1
AC100V
*3
LEAKAGE
CURRENT[mA] AC230V
*3
NUMBER OF SLOT
AC90 - 150V
*4
TOTAL
OUTPUT[W]
AC170 - 264V
*4
START-UP TIME[ms]
*1
HOLD-UP TIME[ms]
AUXILIARY POWER (AUX)
ALARM (PR)
INPUT-OUTPUT, RC, AUX
INPUT-FG
OUTPUT, RC, AUX(PR)-FG
*5
OPERATING TEMP.,HUMID. AND ALTITUDE
*4
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
INPUT
ACE
OUTPUT
FUNCTION
ISOLATION
ENVIRONMENT
SAFTY AND
AGENCY APPROVALS
NOISE
CONDUCTED NOISE
REGULATIONS
CASE SIZE
HARMONIC ATTENUATOR
*6
OTHERS
ACE300F
ACE450F
ACE650F
ACE900F
AC85 - 264 1f / DC120 - 350 (option=-U AC70 or DC100 - refer to instruction manual 5)
47 - 63
3.7typ
5.7typ
8.0typ
11typ
2.0typ
3.1typ
4.2typ
5.7typ
0.99typ
0.95typ
15 / 30typ
*7
15 / 50typ
*7
*7
30 / 30typ
30 / 50typ
*7
74typ
75typ
77typ
77typ
78typ
78typ
80typ
80typ
0.5max
0.95max
6
4
5
5
250
400
600
800 (Peak 1k)
900 (Peak 1k)
300
450
650
500max (ACIN100V, Io=100%)
20typ (ACIN100V, Io=100%)
12V 0.1A (Only for Remote ON/OFF) (option=-J 5V0.1A)
FAN alarm, LINE alarm
AC3,000V 1minute, Cutoff current=10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current=10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current=100mA, DC500V 50MW min (At Room Temperature)
-20 to +70C, 20 - 90%RH (Non condensing) 3,000m (10,000feet ) max
-20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
19.6m/s
2
(2G) , 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G) , 11ms, once each X, Y and Z axis
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, Complies with DEN-AN (At only AC input)
UL60601-1, EN60601-1 (At only AC input) (Refer to instruction manual 7)
Complies with FCC-B, VCCI-B, CISPR22-B and EN55022-B
Complies with IEC61000-3-2
*
9
103X63.5X254mm (WXHXD) 127X63.5X254mm (WXHXD) 127X63.5X279mm (WXHXD) 177.5X63.5X254mm (WXHXD)
[4.06X2.5X10 inches]
[5X2.5X10 inches]
[5X2.5X10.98 inches]
[6.99X2.5X10 inches]
1.7max
Forced cooling (built-in)
2.2max
2.4max
*6
*7
*8
*9
*
WEIGHT[kg]
COOLING METHOD
3.0max
Case size contains neither the terminal blocks, screw nor.
Primary inrush current / Secondary inrush current.
Please contact us about safety approvals for the model with option.
Please contact us about class C.
A sound may occur from power supply at pulse loading.
*1
In case of modular power supply, the value changes by
composing and load factor of installed ouput modules.
The values in specifications mean each the model are
composed of voluntary modules that are 5V (code : C), 12V
(code : E), 24V (code : H) and the output power is total
ouput wattage under the prescribed conditions.
*2
More than 3sec. to restart. Io=100%
*3
Complies with IEC60950 and DEN-AN 60Hz and 100% load.
*4
Refer to instruction manual 4.2 Derating in detail.
*5
Each output module, RC and AUX are isolated.
ACE-2

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号