30W Single Output Industrial DIN Rail Power Supply
Features :
Universal AC input/Full range
DR-30
series
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
Isolation class
LED indicator for power on
100% full load burn-in test
3 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
OVER LOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
EMC
(Note 4)
DR-30-5
5V
3A
0 ~ 3A
15W
4.75 ~ 5.5V
2.0%
1.0%
1.0%
100ms, 30ms/230VAC
100ms/230VAC
85 ~ 264VAC
47 ~ 63Hz
74%
DR-30-12
12V
2A
0 ~ 2A
24W
120mVp-p
10.8 ~ 13.2V
1.0%
1.0%
1.0%
100ms, 30ms/115VAC at full load
30ms/115VAC at full load
120 ~ 370VDC
81%
DR-30-15
15V
2A
0 ~ 2A
30W
120mVp-p
13.5 ~ 16.5V
1.0%
1.0%
1.0%
DR-30-24
24V
1.5A
0 ~ 1.5A
36W
150mVp-p
21.6 ~ 26.4V
1.0%
1.0%
1.0%
RIPPLE & NOISE (max.)
Note.2
80mVp-p
82%
83%
0.88A/115VAC
0.48A/230VAC
COLD START 15A/115VAC
30A/230VAC
105 ~ 160% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
-20 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved, Design refer to EN50178
I/P-O/P:3KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms/500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55011,EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3 Heavy industry level, criteria A
441.5K hrs min. MIL-HDBK-217F (25
78*93*56mm (W*H*D)
0.27Kg; 48pcs/14Kg/1.02CUFT
)
OTHERS
NOTE
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:DR-30-SPEC 2005-09-13