PS-45 Series
Specifications
Features:
• Universal AC input / full range
• Protections: Short Circuit / Overload / Over Voltage/
Overtemperature
• Cooling by free air convection
• DIN rail mountable
• UL508 approved
• LED indicator for power on
• Fix switching frequency at 100kHz
• 100% full load burn-in test
• 3 year warranty
OUTPUT
Cat. No.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (max.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVERVOLTAGE
OVERTEMPERATURE
PS-4505
5V
5A
0 ~ 5A
25W
100mVp-p
4.75 ~ 5.5V
±2.0%
PS-4512
12V
3.5A
0 ~ 3.5A
42W
200mVp-p
10.8 ~ 13.2V
±1.0%
PS-4515
15V
2.8A
0 ~ 2.8A
42W
240mVp-p
13.5 ~ 16.5V
±1.0%
±1.0%
±1.0%
PS-4524
24V
2A
0 ~ 2A
48W
480mVp-p
21.6 ~ 26.4V
±1.0%
±1.0%
±1.0%
Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor
Tolerance: includes set up tolerance, line regulation and load regulation.
INPUT
±1.0%
±1.0%
±1.0%
±1.0%
800ms, 60ms / 230VAC at full load
60ms / 230VAC at full load
85 ~ 264VAC
120 ~ 370VDC
47 ~ 63Hz
72%
77%
1.5A / 115VAC
0.75A / 230VAC
COLD START 28A / 115VAC; 56A / 230VAC
≤1mA
/ 240VAC
105 ~ 160% rated output power
77%
80%
PROTECTION
Protection type: Constant current limiting recovers automatically after fault condition is removed
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
Protection type: Shut down overvoltage, clamping by zener diode
Tj 135˚C typically (U1) detect on heat sink of power transistor
Protection type: Shut down overvoltage, re-power on to recover
ENVIRONMENT
WORKING TEMPERATURE
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MOUNTING
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
SAFETY & EMC
-10 ~ +50˚C (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85˚C, 10 ~ 95% RH
±0.03% / ˚C (0 ~ 50˚C)
Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes
Compliance to IEC60068-2-6
UL508
EN60950-1 compliant
I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC (25°C; 70% RH)
Compliance to EN55011; EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204; EN55024; EN61000-6-2;
heavy industry level; criteria A
The power supply is considered a component which will installed into a final equipment.
The final equipment must be re-confirmed that it still meets EMC directives.
OTHERS
MTBF
DIMENSION
PACKING
364.6K hrs min. MIL-HDBK-217K (25˚C)
93x78x67mm (LxWxH)
0.31Kg; 48pcs / 16.1Kg / 1.3CUFT
All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature
For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power.