SXN15 Series
DC-DC CONVERTERS
•
•
•
•
•
•
•
•
•
•
•
Dual positive output
15 W High Efficiency DC-DC Converters
1
Two positive outputs
Output voltage tracking
High efficiency
Approved to EN60950, UL/cUL1950
Wide operating temperature up to and exceeding 65 °C
(natural convection)
Up to 100% load imbalance
Trim function
No minimum load
Complies with ETS 300 019-1-3/2-3
Fully compliant with ETS 300 386-1
Available RoHS compliant
The SXN15 is a new high efficiency open-frame isolated 15 Watt converter series. The first
two models in the series feature an input voltage range of 33 Vdc to 75 Vdc and are
available in output voltages of 5 V/3.3 V and 3.3 V/2.5 V. The output voltage on each model
is adjustable from 90% to 110% of the nominal value. Typical efficiencies for the models are
86% for the 5 V/3.3 V and 85% for the 3.3 V/2.5 V version. The SXN15 series also has a
remote ON/OFF capability with active high or active low logic. Overcurrent and overvoltage
protection features are included as standard. With full international safety approval including
EN60950 and cUL1950, the SXN15 reduces compliance costs and time to market.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
TÜV
2 YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage adjustability
Voltage setpoint
Voltage accuracy
(See Note 8)
Output voltage
(Over all line and
load conditions)
Minimum load
Ripple and noise
20MHz bandwidth
Transient response
50% to 75% to 50%
Both outputs
Both outputs
Both outputs
5 V/3.3 V
3.3 V/2.5 V
4.931
3.236
3.297
2.431
V
V
V
V
<
<
<
<
±10% min.
±2% typ.
±4% max.
V
o1
V
o2
V
o1
V
o2
<
<
<
<
5.133
3.368
3.431
2.531
V
V
V
V
EMC CHARACTERISTICS
ETS 300 386-1 table 5
Conducted emissions
Radiated emissions
Immunity:
ESD air
ESD contact
EFT DC power
EFT signal
Radiated field enclosure
Surges indoor signal
Conducted (dc power)
Conducted (signal)
Input transients
EN55022 (See Note 6)
Level A
EN55022 (See Note 6)
Level B
EN55022 (See Longform Datasheet) Level B
EN61000-4-2 8 kV, 15 kV
EN61000-4-2 6 kV, 8 kV
EN61000-4-4 2 kV, 4 kV
EN61000-4-4 1 kV, 2 kV
EN61000-4-3 10 V/m
EN61000-4-5 500 V
EN61000-4-6 10 V
EN61000-4-6 10 V
ETS 300 132-2, ETR 283
0%
140 mV pk-pk max.
50 mV rms max.
D05-3V3J, V
01
D05-3V3J, V
02
D3V3-2V5J, V
01
D3V3-2V5J, V
02
To 1.0%, no external cap.
10 A rms
180
100
150
100
mV max.
mV max.
mV max.
mV max.
100 µs
(See Note 7)
GENERAL SPECIFICATIONS
Efficiency
Operational insulation
Input fuse
Switching frequency
Approvals and
standards
Weight
Fixed
Input/output
See table
1500 Vdc
2.0 A slow blow
265 kHz
Peak dev. settling time
Short circuit protection
(Isc)
Tracking
INPUT SPECIFICATIONS
Input voltage range
Input current
UVLO turn ON voltage
UVLO turn OFF voltage
Continuous
automatic recovery
Max. differential 0.7 V during
start-up
UL/cUL1950, EN60950
(See Notes 1, 2 and 3)
TÜV Rheinland
12 g (0.42 oz)
150µm
MIL-HDBK-217F
1,790,000 ho urs
48S05J @ 48 Vin, 40 °C,
100% load ground benign
>1,500,000 hours
BELLCORE 332
48 Vin nominal
No load
Remote OFF
33-75 Vdc
35 mA max.
25 mA max.
33 V (typ)
30 V (typ)
Coplanarity
MTBF
Representative model:
Active high remote ON/OFF
Logic compatibility
ON
OFF
Start-up time
Nominal line
(See Note 4)
Open collector ref. to -input
Open circuit or >2 Vdc
<1.2 Vdc
2.5 ms (typ)
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
(See Note 5)
Operating ambient
temperature
Non-operating
-40 °C to +65 °C
-40 °C to +120 °C
File Name: sxn15d.pdf Rev (02): 29 Mar 2006
SXN15 Series
DC-DC CONVERTERS
INPUT
VOLTAGE
33-75 Vdc
33-75 Vdc
Notes
1
2
Dual positive output
15 W High Efficiency DC-DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT VOLTAGE
1
2
5V
3.3 V
3.3 V
2.5 V
OUTPUT CURRENT
1
2
3A
3.5 A
4.5 A
4.5 A
OVP
1
6.2 V
4V
2
4.2 V
3V
TYPICAL
EFFICIENCY
86%
85%
MODEL
NUMBER
(4,9)
SXN15-48D05-3V3J
SXN15-48D3V3-2V5J
PIN CONNECTIONS
PIN NUMBER
1
2
3
4
5
6
7
8
9
10
11
FEATURE
V
o1
+
Com
V
o2
+
Trim
N/C
N/C
N/C
On/Off
N/C
Vin -
Vin +
3
4
5
6
7
8
9
User must provide recommended fuses in order to comply with safety
approvals.
Maximum continuous output power.
15 Watts for D05-3V3J model.
11.55 Watts for D3V3-2VJ5 model.
Maximum temperature on hot spots not to exceed 115 °C.
Refer to Longform datasheet for details.
The SXN15 features ‘Active High’ Remote ON/OFF as standard. An
‘Active Low’ Remote ON/OFF version is also available. To order the
‘Active Low’ version of the SXN15-48D05-3V3J please add the suffix ‘-R’
towards the end of the part number, i.e. SXN15-48D05-3V3-RJ. As part
numbers cannot exceed 18 characters when ordering the ‘Active Low’
version of the SXN15-48D3V3-2V5J please add the suffix ‘R’ towards the
end of the part number, i.e. SXN15-48D3V3-2V5RJ.
Operating ambient temperatures are specified at natural convection.
Higher operating temperatures are possible with increased airflow.
See Application Note 116 for further details.
Measured with external filter. See Application Note 116 for further details.
Signal line assumed < 3 m in length.
This parameter is calculated at worst case line, load, temperature and
initial conditions.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
1.905 (48.39)
All Dimensions in Inches [mm]
TOP VIEW
1.010 (25.65)
SIDE VIEW
1
0.335 (8.51)
0.110 (2.79)
0.820 (20.83)
0.020 (0.51)
0.120 (3.05)
1
2
3
4
5
6
0.072 (1.83)
0.070 (1.78)
Tolerance:
±
.015 (± .38)
Recommended Land & Hole Pattern
1.031 (26.19)
BOTTOM VIEW
0.840 (21.37)
0.197 (5.00)
11
10
9
8
7
0.197 (5.00)
0.347 (8.81)
0.105 (2.67)
0.302 (7.67)
1.136 (28.85)
1.483 (37.67)
1.680 (42.67)
11
10
9
8
7
1.020 (25.91)
0.800 (20.32)
0.130 (3.30)
0.110 (2.79)
1
2
3
4
5
6
1.705 (43.31)
International Safety Standard Approvals
UL/cUL 1950 3rd edition. File No. E135734
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
TÜV
TÜV Rheinland. File No. 10401-336-0196. Licence No. 40004290
Datasheet © Artesyn Technologies® 2006
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items:
Application Note
Longform Data Sheet
www.artesyn.com
File Name: sxn15d.pdf Rev (02): 29 Mar 2006