D38999/20FG39PD

Description
Circular MIL Spec Connector
CategoryThe connector   
File Size273KB,2 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

D38999/20FG39PD Overview

Circular MIL Spec Connector

D38999/20FG39PD Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerGlenair
Product CategoryCircular MIL Spec Connector
Number of Positions39 Position
Insert Arrangement21 - 39
Contact GenderPin (Male)
MIL TypeMIL-DTL-38999 III
ProductReceptacles
Shell Size21
Shell StyleWall Mount
Mounting StylePanel
Termination StyleCrimp
Current Rating7.5 A, 13 A
Shell PlatingNickel
Shell MaterialAluminum
Factory Pack Quantity1
COTS EQUIVALENT
MIL-DTL-38999 Series III Environmental connectors
233-105 Crimp contact series with accessory threads
How To Order - 233-105
Sample Part Number
Series / Basic Part No.
Connector Style
Material and Finish
233-105
MIL-DTL-38999 Series III Environmental Connector
20
= Wall mount receptacle
24
= Jam nut receptacle
26
= Plug
See Table I
-20
NF
17-8
P
N
-LC
Shell Size-Insert Arrangement
Per MIL-STD-1560
Contact Type
Alternate Polarization
Mod Code for Less Contacts
P
= Pin, 500 cycles
A
= Pin insert, less standard contacts
A, B, C, D, E, N
= Normal
Connector marked with
P
or
S
according to insert but supplied less contacts
S
= Socket, 500 cycles
B
= Socket insert, less standard contacts
Table I: Material and Finish
38999
F
G
T
W
Z*
233-105
ME
MA
MT
NF
ZR
Aluminum
Material
Finish Description
Electroless nickel (48 hr. salt spray)
Space-grade electroless nickel, matte (48 hr. salt spray)
Ni-PTFE
Cadmium O.D. over electroless nickel (500 hr. salt spray)
Black zinc-nickel over electroless nickel
RoHS
½
*qualification pending
Connector Mating and Accessory Thread Dimensions
Shell
Size
Code
A
B
C
D
E
F
G
H
J
Shell
Size
9
11
13
15
17
19
21
23
25
A Thread
.6250-.1P-.3L-TS-2A
.7500-.1P-.3L-TS-2A
.8750-.1P-.3L-TS-2A
1.0000-.1P-.3L-TS-2A
1.1875-.1P-.3L-TS-2A
1.2500-.1P-.3L-TS-2A
1.3750-.1P-.3L-TS-2A
1.5000-.1P-.3L-TS-2A
1.6250-.1P-.3L-TS-2A
J Thread
M12 X 1.0-6g 0.100R
M15 X 1.0-6g 0.100R
M18 X 1.0-6g 0.100R
M22 X 1.0-6g 0.100R
M25 X 1.0-6g 0.100R
M28 X 1.0-6g 0.100R
M31 X 1.0-6g 0.100R
M34 X 1.0-6g 0.100R
M37 X 1.0-6g 0.100R
Wire Accommodation
Contact Size
23
22D
20
16
12
Wire Gauge
#22 - #28
#22 - #28
#20 - #24
#16 - #20
#12 - #14
NOTES
1. 233-105 is designed to meet or exceed the mechanical,
electrical, environmental and dimensional requirements of
D38999/20, /24 & /26.
2. Insert arrangements IAW MIL-STD-1560, Glenair HD and size #8
shielded contact insert arrangements available only in COTS
series
12
3. Blue color band indicates rear release retention system.
4. Connector is supplied with contacts (including spares),
insertion/removal tool and sealing plugs.
5. Dimensions in inches (millimeters) are subject to change
without notice
6. Consult factory for additional information
© 2016 Glenair, Inc • 1211 Air Way, Glendale, CA 91201 • 818-247-6000 • www.glenair.com • U.S. CAGE code 06324 • MIL-DTL-38999 Series III brochure
Dimensions in inches (millimeters) are subject to change without notice
[Development and application based on NUCLEO-F746ZG motor] 2. Based on SDK5.4.5-project construction
1. Prepare toolsPlease install the following PC software tools in advance:X-CUBE -MCSDK MCSDK or X-CUBE -MCSDK -FUL FUL FULSTM32CubeM STM32CubeM STM32CubeMX (v5.3 or above) and firmware libraryST -LIN...
annysky2012 Motor Drive Control(Motor Control)
What is "j" in the resultant vector formula of three-phase symmetrical sinusoidal current?
I'd like to ask, I've just started learning vector control, what is "j" in the synthetic vector formula of three-phase symmetrical sinusoidal current? Thank you! !...
sunnjh Motor Drive Control(Motor Control)
Linux Network Programming-How does a TCP client obtain the server IP to connect to?
1 Problem Introduction When developing socket communication, TCP or UDP are generally used as transport layer protocols. UDP (User Datagram Protocol) is a connectionless protocol . It does not need to...
DDZZ669 ARM Technology
The Difference Between Oscilloscope Channel Coupling and Trigger Coupling
In electronic circuits, sending the output signal of the previous circuit (or signal source) to the next circuit (or load) is called coupling. The function of coupling is to transfer (or convert) the ...
Micsig麦科信 Test/Measurement
Official Pioneer Tips: Unlocking the 400Mhz GPIO Flip Frequency of the HPM6700 Series
In this issue, the Pioneer technical officer will show you how to use the HPM6700 series to achieve a GPIO flip frequency of up to 400Mhz. Scroll down to learn more!--------- "Unlocking Journey" start...
谍纸天眼 Domestic Chip Exchange

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号