TECHNICAL DATA SHEET
BNC 50
Ω
BULKHEAD JACK
51K507-801N4
All dimensions are in mm; tolerances according to ISO 2768 m-H
Interface
According to
IEC 60169-8, MIL-PRF-39012, CECC 22120
Documents
Assembly instruction
Panel piercing
51 T
B2
Material and plating
Connector parts
Center contact
Outer contact
Body
Dielectric
Crimping ferrule
Material
Beryllium copper
Brass
Brass
PTFE
Copper
Plating
Gold, min. 0.8 µm, over chemical nickel
Flash white bronze over silver(e.g. Optargen®)
Flash white bronze over silver(e.g. Optargen®)
Flash white bronze over silver(e.g. Optargen®)
RF_35/12.04/3.0
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel.: +49 8684 18-0
Fax: +49 8684 18-499
email: info@rosenberger.de
Page
1/2
TECHNICAL DATA SHEET
BNC 50
Ω
BULKHEAD JACK
51K507-801N4
50
Ω
DC to 10 GHz
≥
25 dB, DC to 1 GHz
≥
23 dB, 1 to 2.5 GHz
≥
20 dB, 2.5 to 3 GHz
≤
0.05 x
f [GHz]
dB, DC to 3 GHz
Electrical data
Impedance
Frequency
Return loss
Insertion loss
Insulation resistance
Center contact resistance
Outer contact resistance
Test voltage
Working voltage
Power handling
(at 20 °C, sea level, VSWR 1.0)
- Limitations are possible due to the used cable type -
≥
5 x10
3
MΩ
≤
1.5 mΩ
≤
1 mΩ
1500 V rms
400 V rms
≤
80 W @ 2 GHz
Mechanical data
Mating cycles
Center contact captivation: axial
min. 500
≥
15 N
Environmental data
Temperature range
Thermal shock
Corrosion
Vibration
Shock
Moisture resistance
-55°C to +155°C
MIL-STD-202, Meth.
MIL-STD-202, Meth.
MIL-STD-202, Meth.
MIL-STD-202, Meth.
MIL-STD-202, Meth.
107,
101,
204,
213,
106
Cond.
Cond.
Cond.
Cond.
B
B
B
G
Tooling
Crimping tool
Crimp insert
11W150-000
11W150-402
Suitable cables
RG 178 B/U, RG 196 A/U
Packing
Standard
Weight
100 pcs in bag
10.3 g/pce
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
RF_35/12.04/3.0
Draft
Inge Mühlauer
Date
13/07/04
Approved
Rong Fang
Date
18/10/05
Rev.
b00
Engineering change number
05-0566
Name
Inge Mühlauer
Date
18/10/05
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel.: +49 8684 18-0
Fax: +49 8684 18-499
email: info@rosenberger.de
Page