Features
●
●
●
●
●
●
●
●
●
●
Single Outputs up to 15A
Input/Output 1.6kVDC Isolation
Adjustable Output Voltage
No Minimum Load
Under -Voltage Lockout
Industry Standard Footprint
Fixed Operating Frequency
Halt Tested
Compact 61.0 x 57.91 x 12.7mm Package
High Efficiency to 91%
INNOLINE
DC/DC-Converter
RP50-S
Series
50 Watt
Single
Output
Selection Guide
Part
Number
Input
Voltage
(VDC)
18 – 36
18 – 36
18 – 36
18 – 36
18 – 36
36 – 75
36 – 75
36 – 75
36 – 75
36 – 75
Output
Voltage
(VDC)
1.8
2.5
3.3
5
15
1.8
2.5
3.3
5
15
Output
Line
Load
Current Regulation Regulation
(A)
(mV)
(mV)
15
15
15
10
3.3
15
15
15
10
3.3
4
5
7
10
30
4
5
7
10
30
6
8
10
15
45
6
8
10
15
45
Input Efficiency
Current
(A)
%
1.36
1.86
2.40
2.40
2.40
1.36
1.86
2.40
2.40
2.40
86
87
89
90
89
87
89
90
91
90
Single Output
RP50-241.8S
RP50-242.5S
RP50-243.3S
RP50-2405S
RP50-2415S
RP50-481.8S
RP50-482.5S
RP50-483.3S
RP50-4805S
RP50-4815S
Notes:
1. Maximum output deviation is 10% inclusive of remote sense. If remote sense is not being used,
the +Vsense should be connected to its corresponding +Vout
2. Measured with a 1uF M/C and a 10µF T/C.
3. An external filter capacitor is required for normal operation. The capacitor should be capable of handing 1A
ripple current for 48V/24V models. RECOM suggests: Nippon chemi-con KMF series, 220µF/100V, ESR 90m
Ω
.
4. The negative/ positive logic and pin length are optional ( see table ). The pin voltage is referenced to
negative input.
5. Heat sink is optional and P/N: 7G-0021, 7G-0022, 7G-0023, 7G-0024.
6. The RP50 meets level A and level B conducted emissions only with external components connected before
the input pin to the converter.
7. Maximum value at nominal input voltage and full load.
8. Typical value at nominal input voltage and full load.
9. BASEPLATE GROUNDING : Base-plate should be grounded at one of the four screw bolts prior to operation.
10. The converter is provided by basic insulation.
11. “N” for Negative remote ON/OFF.
N
12. “P” for
Positive
remote ON/OFF.
P
178
July-2006
www.recom-international.com
INNOLINE
DC/DC-Converter
Specifications (refer to the standard application circuit, Ta: 25°C)
Input Voltage Range
Unde-Voltage Lockout Start-up Voltage
Unde-Voltage Lockout Shuntdown Voltage
Input Filter (Note 3)
Input voltage variation
Input Surge Voltage 100mS max
Start up time
Input Reflected-Ripple Current
(5Hz to 20Hz, 12µH Source inpedance)
Remote ON/OFF (Note 4)
(Positive logic)
(Negative logic)
Continuous Output Power
Output Voltage Accuracy (full load and nominal Vin)
Output Voltage Adjustment (Note 1)
Minimum Load
Line Regulation
Load Regulation
Remote Sense (Note 1)
Ripple and Noise 20MHz bandwidth (Note 2)
Temperature Coefficient
Transient Response Recovery Time (25% load step change)
Over Voltage Protection threshold (Hiccup)
Over Current Protection threshold
Short Circuit Protection
Efficiency (at nominal input voltage, full load)
Isolation Voltage
Input to Output
Input to Case
Output to Case
low line to high line at full load
0% to 100% full load
18 - 36, 36-75VDC
24V input
48V input
24V input
48V input
dv/dt
24V input
48V input
Nominal Vin and constant resistive load
24V input
48V input
ON=Open or 3.0V < Vr < 15V,
OFF=Short or 0V < Vr < 1.2V,
ON=Short or 0V < Vr < 1.2V,
OFF=Open or 3.0V < Vr < 15V,
RP50-S
Series
(24, 48V nom.)
17V typ.
34V typ.
15V typ.
32V typ.
L-C type
5V/ms max
(Complies with ETS300 132 part4.4)
50VDC
100VDC
25mS typ.
50mAp-p
20mAp-p
I
IN
=50µA max.
I
IN
=1mA max.
I
IN
=1mA max.
I
IN
=50µA max.
50W max.
±1.5%
+10%, -20%
0%
See table
See table
10% of Vout
100mVp-p
±0.02%/ºC
200µs
115% ~ 130% of Vout
110% ~ 140% of Iout Rated
Hiccup, Automatic recovery
up to 91%.
1600VDC min.
1000VDC min.
1000VDC min.
10
7
Isolation Resistance
Isolation Capacitance
Operating Frequency
Operating Temperature Range
Over Temperature Protection
Storage Temperature Range
Humidity max., Non-condensing
Thermal Shock
Ω
min.
2500pF max.
300KHz typ.
-40ºC to +100ºC (base plate)
110°C
-55°C to +125°C
95%
MIL-STD-810D
Continued next page
www.recom-international.com
July-2006
179
INNOLINE
DC/DC-Converter
Specifications (refer to the standard application circuit, Ta: 25°C)
Vibration
Conducted Emissions
10 ~ 55Hz 2G, 3minutes period, 30minutes analog
EN55022 (Note 7)
EN55022 (Note 7)
Radiated Emisssions
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
Case Material
Weight
MTBF Bellcore TR-NWT-000332, Tc=40°C, Io=80% max.
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
RP50-S
Series
X, Y and Z
Level A
Level B
Level A
Perf. Criteria2
Perf. Criteria2
Perf. Criteria2
Perf. Criteria2
Perf. Criteria2
Open with Aluminium base plate
50g
3000 x10 hours
3
Characteristics
Efficiency vs Output Load
for 5V only
100
90
80
Efficiency (%)
70
60
50
10
20
30
40
50
60
70
80 90 100
Output Power (%) Ta=25°C
48V Input Without Heatsink
110
90
70
1.) LFM590
2.) LFM400
3.) LFM200
4.) LFM20
48V Input With Heatsink (7G-0022)
110
90
70
1.) LFM590
2.) LFM400
3.) LFM200
4.) LFM20
Output Power (%)
50
30
10
-40
-20
0
20
40
60
1 2
34
Output Power (%)
50
30
10
-40
-20
0
20
40
60
80
1 2
34
80
100
100
Ambient Temperature (°C)
Ambient Temperature (°C)
180
July-2006
www.recom-international.com
INNOLINE
DC/DC-Converter
Package Style and Pinning (mm)
RP50-S
Series
3rd angle
projection
57.91
60.96
12.70
5.08
48.26
Side View
50.80
4xM3 x 0.5 ( Note 10)
Pin Connections
Pin #
Function
1
–Vin
2
Case
3
Remote ON/OFF
4
+Vin
5
–Vout
6
–Vsense
7
Trim
8
+Vsense
9
+Vout
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Pin pitch tolerance 0.35mm
Pin Ø
1.016 mm
1.016 mm
1.016 mm
1.016 mm
2.032 mm
1.016 mm
1.016 mm
1.016 mm
2.032 mm
1
2
35.56
15.24
3
4
5
6
7
8
9
17.78
10.16
25.40
Bottom View
External Output Trimming
Output can be externally trimmed by using the method
shown below.
Product Options Table
Option
Negative remote ON/OFF logic, 0.20” pin length (standard)
Negative remote ON/OFF logic, 0.145” pin length
Negative remote ON/OFF logic, 0.11” pin length
L
K
P
S
M
Suffix
7
Trim Up
R
U
6
Trim Down
R
D
Positive remote ON/OFF logic, 0.20” pin length
Positive remote ON/OFF logic, 0.145” pin length
Positive remote ON/OFF logic, 0.11” pin length
8
7
Example: RP50-483.3S/P
www.recom-international.com
July-2006
181