EEWORLDEEWORLDEEWORLD

Part Number

Search

7024RKIV

Description
7024RKIV=RLY,STD,OFF,4P,60V,300S,I,V
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size975KB,7 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Download Datasheet Parametric Compare View All

7024RKIV Online Shopping

Suppliers Part Number Price MOQ In stock  
7024RKIV - - View Buy Now

7024RKIV Overview

7024RKIV=RLY,STD,OFF,4P,60V,300S,I,V

7024RKIV Parametric

Parameter NameAttribute value
Product CategoryElectromechanical relay
Relay typedelay
Multiple timing rangesWithout
Input voltage (VDC)60
Control typeKnob
Terminal Current Rating (A)10A at 240VAC
delay1 - 300 seconds
Terminal arrangement4 Form C,4PDT,4 C/O
Termination typeScrew terminal
Installation typeMounting brackets
Dimensions (L x W x H) (approximate)114.8 x 65.3 x 71.9 mm [ 4.523 x 2.572 x 2.832 in ]
Operating temperature range (°C)-30 – 75
operating modeTurn off delay
OptionsTransient/Surge Protection, Tamper Cap - Clear
Repeatability (maximum)±10%
Specialty Relays
AGASTAT 7000 Series, Industrial Electropneumatic Timing Relay
Design & Construction
There are three main components of
Series 7000 Timing Relays:
Timing Head
circulates air through a
variable length to provide linearly
adjustable timing. Patented design pro-
vides easy adjustment and long service
life under severe operating conditions.
Precision-Wound Potted Coil
Total sealing without external leads
eliminates moisture problems, gives
maximum insulation value.
Snap-Action Switch Assembly
custom-designed over-center mecha-
nism provides snap action. Standard
switches are DPDT arrangement.
Each of these subassemblies forms
self-contained modules assembled at
the factory with the other two to afford
a wide choice of operating types, coil
voltages, and timing ranges.
The squared design with front terminals
and rear mounting permits the grouping of
Series 7000 units side-by-side in mini-
mum panel space. Auxiliary switches may
be added in the base of the unit, without
affecting the overall width or depth.
On-delay model 7012 (delay on pickup)
Applying voltage to the coil (L1-L2) for
at least 50 msec starts a time delay
lasting for the preset time. During this
period the normally closed contacts
(3-5 and 4-6) remain closed. At the end
of the delay period the normally closed
contacts break and the normally open
contacts (1-5 and 2-6) make. The
contacts remain in this transferred
position until the coil is deenergized,
at which time the switch returns to its
original position.
De-energizing the coil, either during or
after the delay period, will recycle the
unit within 50 msec.
It will then provide a full delay period
upon re-energization, regardless of how
often the coil voltage is interrupted
before the unit has been permitted to
"time-out" to its full delay setting.
Product Facts
n
n
Available in on-delay, true
off-delay, and on/off-delay
Timing from 0.1 seconds to
60 minutes, in linear
increments
Oversize adjustment knobs,
serrated with high-resolution
markings visible from all
angles makes the timer
easy to set timers
Inherent transient immunity
Standard voltages from
6-550VAC and 12-550VDC
(special voltages available)
Available in 2-pole or 4-pole
models
Numerous enclosure
options — explosion proof,
dust tight, watertight,
hermetically-sealed,
NEMA 1
Auxiliary timed and
instantaneous switches can
be added for greater
switching flexibility
Many mounting options —
Surface mount, Panel
mount, Octal plug-in
mounting
Options: quick-connect
terminals, dial stops, and
transient protection module
Easy-to-reach screw
terminals, all on the face of
the unit, clearly identified
Modular assembly —
timing head, coil assembly
and switchblock are all
individual modules, with
switches field-replaceable
File E15631,
File LR29186
R
R
n
Off-delay model 7022 (delay on dropout)
Applying voltage to the coil (for at least
50 msec) will transfer the switch,
breaking the normally closed contacts
(1-5 and 2-6), and making the normally
open contacts (3-5 and 4-6). Contacts
remain in this transferred position as long
as the coil is energized. The time delay
begins immediately upon de-energization.
At the end of the delay period the switch
returns to its normal position.
Re-energizing the coil during the delay
period will immediately return the timing
mechanism to a point where it will pro-
vide a full delay period upon subsequent
de-energization. The switch remains in
the transferred position.
n
n
Operation
Two basic operating types are available.
“On-Delay” models provide a delay period
on energization, at the end of which the
switch transfers the load from one set of
contacts to another. De-energizing the
unit during the delay period immediately
recycles the unit, readying it for another
full delay period on re-energization.
In "Off-Delay" models the switch trans-
fers the load immediately upon energiza-
tion and the delay period does not begin
until the unit is de-energized. At the end
of the delay period the switch returns to
its original position. Re-energizing the
unit during the delay period immediately
resets the timing, readying it for another
full delay period on de-energization.
No power is required during the timing
period, providing a true off delay.
In addition to these basic operating types,
“Double-Head” models offer sequential
delays on pull-in and drop-out in one
unit. With the addition of auxiliary
switches the basic models provide two-
step timing.
Note: Seismic & radiation tested
E7000 models are available.
Consult factory for detailed
information.
n
n
n
n
n
n
n
n
Note:
7032 types and certain models with accessories are not agency approved.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of the
agencies/laboratories and review them to ensure the product meets the requirements
for a given application.
Consult factory for ordering information.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
Dimensions are in millimeters
unless otherwise specified.
USA: +1 800 522 6752
Asia Pacific: +86 0 400 820 6015
UK: +44 800 267 666
For additional support numbers
please visit www.te.com
12–8
Catalog 5-1773450-5
Revised 3-13
www.te.com

7024RKIV Related Products

7024RKIV 7022RHA2 4-1755074-1
Description 7024RKIV=RLY,STD,OFF,4P,60V,300S,I,V 7022RHA2=60V DC 3-30 MIN 7012ADLY1=RLY,STD,ON,2P,120V,50S,L,Y1
Product Category Electromechanical relay Electromechanical relay -
Relay type delay delay -
Multiple timing ranges Without Without -
Input voltage (VDC) 60 60 -
Control type Knob Knob -
Terminal Current Rating (A) 10A at 240VAC 10A at 240VAC -
delay 1 - 300 seconds 3-30 minutes -
Terminal arrangement 4 Form C,4PDT,4 C/O 2 Form C,DPDT,2 C/O -
Termination type Screw terminal Dual quick connect terminals -
Installation type Mounting brackets Mounting brackets -
Dimensions (L x W x H) (approximate) 114.8 x 65.3 x 71.9 mm [ 4.523 x 2.572 x 2.832 in ] 114.8 x 65.3 x 71.9 mm [ 4.523 x 2.572 x 2.832 in ] -
Operating temperature range (°C) -30 – 75 -30 – 75 -
operating mode Turn off delay Turn off delay -
Repeatability (maximum) ±10% ±10% -

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号