Changes to Ordering Guide .......................................................... 23
8/10—Rev. 0 to Rev. A
Changes to Figure 8 ...........................................................................7
Changes to Figure 15 Caption and Figure 16 Caption .................8
Changes to Figure 17 Caption and Figure 18 Caption .................9
Changes to Ordering Guide .......................................................... 21
3/10—Revision 0: Initial Version
Rev. E | Page 2 of 24
Data Sheet
SPECIFICATIONS
ADP151
V
IN
= (V
OUT
+ 0.4 V) or 2.2 V, whichever is greater; EN = V
IN
, I
OUT
= 10 mA, C
IN
= C
OUT
= 1 µF, T
A
= 25°C, unless otherwise noted.
Table 1.
Parameter
INPUT VOLTAGE RANGE
OPERATING SUPPLY CURRENT
Symbol
V
IN
I
GND
Conditions
T
J
= −40°C to +125°C
I
OUT
= 0 µA
I
OUT
= 0 µA, T
J
= −40°C to +125°C
I
OUT
= 100 µA
I
OUT
= 100 µA, T
J
= −40°C to +125°C
I
OUT
= 10 mA
I
OUT
= 10 mA, T
J
= −40°C to +125°C
I
OUT
= 200 mA
I
OUT
= 200 mA, T
J
= −40°C to +125°C
EN = GND
EN = GND, T
J
= −40°C to +125°C
I
OUT
= 10 mA
T
J
= −40°C to +125°C
V
OUT
< 1.8 V
100 µA < I
OUT
< 200 mA, V
IN
= (V
OUT
+ 0.4 V) to 5.5 V
V
OUT
≥1.8 V
100 µA < I
OUT
< 200 mA, V
IN
= (V
OUT
+ 0.4 V) to 5.5 V
T
J
= −40°C to +125°C
V
OUT
< 1.8 V
100 µA < I
OUT
< 200 mA, V
IN
= (V
OUT
+ 0.4 V) to 5.5 V
V
OUT
≥1.8 V
100 µA < I
OUT
< 200 mA, V
IN
= (V
OUT
+ 0.4 V) to 5.5 V
V
IN
= (V
OUT
+ 0.4 V) to 5.5 V, T
J
= −40°C to +125°C
V
OUT
< 1.8 V
I
OUT
= 100 µA to 200 mA
I
OUT
= 100 µA to 200 mA, T
J
= −40°C to +125°C
V
OUT
≥ 1.8 V
I
OUT
= 100 µA to 200 mA
I
OUT
= 100 µA to 200 mA, T
J
= −40°C to +125°C
V
OUT
< 1.8 V
I
OUT
= 100 µA to 200 mA
I
OUT
= 100 µA to 200 mA, T
J
= −40°C to +125°C
V
OUT
≥1.8 V
I
OUT
= 100 µA to 200 mA
I
OUT
= 100 µA to 200 mA, T
J
= −40°C to +125°C
I
OUT
= 10 mA
I
OUT
= 10 mA, T
J
= −40°C to +125°C
I
OUT
= 200 mA
I
OUT
= 200 mA, T
J
= −40°C to +125°C
I
OUT
= 200 mA
I
OUT
= 200 mA, T
J
= −40°C to +125°C
Min
2.2
Typ
10
20
20
40
60
90
265
350
0.2
1.0
−1
+1
Max
5.5
Unit
V
µA
µA
µA
µA
µA
µA
μA
μA
µA
µA
%
SHUTDOWN CURRENT
OUTPUT VOLTAGE ACCURACY
TSOT/LFCSP
I
GND-SD
V
OUT
V
OUT
−3
−2.5
+2
+1.5
%
%
WLCSP
V
OUT
−2.5
−2
−0.05
0.006
+2
+1.5
+0.05
%
%
%/V
%/mA
%/mA
%/mA
%/mA
%/mA
%/mA
%/mA
%/mA
%/mA
%/mA
mV
mV
mV
mV
mV
mV
REGULATION
Line Regulation
Load Regulation (TSOT/LFCSP)
1
∆V
OUT
/∆V
IN
∆V
OUT
/∆I
OUT
0.012
0.003
0.008
0.004
0.009
0.002
0.006
10
30
150
230
135
200
Load Regulation (WLCSP)
1
∆V
OUT
/∆I
OUT
DROPOUT VOLTAGE
TSOT/LFCSP
WLCSP
2
V
DROPOUT
Rev. E | Page 3 of 24
ADP151
Parameter
START-UP TIME
3
CURRENT-LIMIT THRESHOLD
4
UNDERVOLTAGE LOCKOUT
Input Voltage Rising
Input Voltage Falling
Hysteresis
THERMAL SHUTDOWN
Thermal Shutdown Threshold
Thermal Shutdown Hysteresis
EN INPUT
EN Input Logic High
EN Input Logic Low
EN Input Pull-Down Resistance
OUTPUT NOISE
Symbol
t
START-UP
I
LIMIT
UVLO
RISE
UVLO
FALL
UVLO
HYS
TS
SD
TS
SD-HYS
V
IH
V
IL
R
EN
OUT
NOISE
T
J
rising
Conditions
V
OUT
= 3.3 V
T
J
= 0°C to +125°C
T
J
= −40°C to +125°C
Min
220
Typ
180
300
Data Sheet
Max
400
1.96
1.28
120
150
15
1.2
0.4
2.6
9
9
9
70
55
70
55
70
55
Unit
µs
mA
V
V
mV
°C
°C
V
V
MΩ
µV rms
µV rms
µV rms
dB
dB
dB
dB
dB
dB
2.2 V ≤ V
IN
≤ 5.5 V
2.2 V ≤ V
IN
≤ 5.5 V
V
IN
= V
EN
= 5.5 V
10 Hz to 100 kHz, V
IN
= 5 V, V
OUT
= 3.3 V
10 Hz to 100 kHz, V
IN
= 5 V, V
OUT
= 2.5 V
10 Hz to 100 kHz, V
IN
= 5 V, V
OUT
= 1.1 V
10 kHz, V
IN
= 3.8 V, V
OUT
= 3.3 V, I
OUT
= 10 mA
100 kHz, V
IN
= 3.8 V, V
OUT
= 3.3 V, I
OUT
= 10 mA
10 kHz, V
IN
= 4.3 V, V
OUT
= 3.3 V, I
OUT
= 10 mA
100 kHz, V
IN
= 4.3 V, V
OUT
= 3.3 V, I
OUT
= 10 mA
10 kHz, V
IN
= 2.2 V, V
OUT
= 1.1 V, I
OUT
= 10 mA
100 kHz, V
IN
= 2.2 V, V
OUT
= 1.1 V, I
OUT
= 10 mA
POWER SUPPLY REJECTION RATIO
V
IN
= V
OUT
+ 0.5 V
V
IN
= V
OUT
+ 1 V
PSRR
Based on an end-point calculation using 0.1 mA and 200 mA loads. See Figure 8 for typical load regulation performance for loads less than 1 mA.
Dropout voltage is defined as the input-to-output voltage differential when the input voltage is set to the nominal output voltage. This applies only for output
voltages above 2.2 V.
3
Start-up time is defined as the time between the rising edge of EN and V
OUT
being at 90% of its nominal value.
4
Current-limit threshold is defined as the current at which the output voltage drops to 90% of the specified typical value. For example, the current limit for a 3.0 V
output voltage is defined as the current that causes the output voltage to drop to 90% of 3.0 V (that is, 2.7 V).
1
2
INPUT AND OUTPUT CAPACITOR, RECOMMENDED SPECIFICATIONS
Table 2.
Parameter
Minimum Input and Output
Capacitance
1
Capacitor ESR
1
Symbol
C
MIN
R
ESR
Conditions
T
A
= −40°C to +125°C
T
A
= −40°C to +125°C
Min
0.7
0.001
Typ
Max
Unit
µF
Ω
0.2
The minimum input and output capacitance should be greater than 0.7 μF over the full range of operating conditions. The full range of operating conditions in the
application must be considered during device selection to ensure that the minimum capacitance specification is met. X7R and X5R type capacitors are recommended;
Y5V and Z5U capacitors are not recommended for use with any LDO.