GLASS PASSIVATED SUPER FAST RECTIFIER
VOLTAGE RANGE 50 to 600 Volts CURRENT 30 Ampere
s
FEATURES
* Low switching noise
* Low forward voltage drop
* Low thermal resistance
* High current capability
* Super fast switching speed
* High -reliability
* Good for switching mode circuit
SF301C
THRU
SF307C
MECHANICAL DATA
*
*
*
*
Case: TO-220 mo lded plastic
Epoxy: Device has UL flammability classification 94V-O
Lead: MIL-STD-202E method 208C guaranteed
Mounting position: Any
MAXIMUM RA TINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 C ambient temperature.
o
Dimensions in inches and (millimeters)
MAXIMUM RATINGS
(At T
A
= 25
o
C unless otherwise noted)
RATINGS
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
o
at T
C
= 100 C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Current Squared Time
Typical Thermal Resistance
Typical Junction Capacitance (Note 2)
Operating and Storage Temperature Ra
nge
SYMBOL
V
RRM
V
RMS
V
DC
I
O
I
FSM
I
2
t
R JC
C
J
T
J
, T
STG
120
-55 to + 150
SF301C SF302C
50
35
50
100
70
100
SF303C
150
105
150
SF304C
200
140
200
30.0
300
373.5
3
100
SF305C
300
210
300
SF306C SF307C
400
280
400
600
420
600
UNITS
Volts
Volts
Volts
Amps
Amps
A /Sec
0
2
C/ W
pF
0
C
ELECTRICAL CHARACTERISTICS
(At T
A
= 25
o
C unle otherwise noted)
ss
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 15.0A DC
@T
C
= 25
o
C
Maximum DC Reverse Current
at Rated DC Blocking Voltage
@T
C
= 100 C
o
SYMBOL
V
F
I
R
trr
SF301C
SF302C
SF303C
SF304C
10
500
SF305C
SF306C
SF307C
1.70
UNITS
Volts
uAmps
1.0
1.35
Maximum Reverse Recovery Time (Note 1)
35
50
nSec
2016-01
REV: A
NOTES : 1. Test Conditions: IF = 0.5A, IR = -1.0A, IRR = -0.25A
2. Measured at 1 MHz and applied reverse voltage of 4.0 volts.
3. Suffix “A” =Common Anode.
4. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
RATING AND CHARACTERISTIC CURVES ( SF301C THRU SF307C )
FIG. 1 - TYPICAL FORWARD CURRENT DERATING CURVE
AVERAGE FORWARD CURRENT, (A)
FIG. 2 - TYPICAL REVERSE CHARACTERISTICS
36
30
24
12
6.0
0
Single Phase Half Wave
60Hz Inductive or
Resistive Load
1000
INSTANTANEOUS REVERSE CURRENT, (uA)
TC = 100
100
10
0
50
100
CASE TEMPERATURE, (
150
)
TC = 25
FIG. 3 - MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT
PEAK FORWARD SURGE CURRENT, (A)
300
250
200
150
100
50
0
1
2
5
10
20
50
NUMBER OF CYCLES AT 60Hz
100
8.3ms Single Half Sine-Wave
(JEDED Method
)
1.0
0.1
20
0
40
60
80
100
120
140
PERCENT OF RATED PEAK
REVERSE VOLTAGE, (%)
FIG. 4 - TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS
FIG. 5 - TYPICAL JUNCTION CAPACITANCE
JUNCTION CAPACITANCE, (pF)
INSTANTANEOUS FORWARD CURRENT, (A)
80
C
175
150
125
SF
30
40
SF
3
04
20
SF
30
1
10
4
F
~S
C
05
7C
F3
30
S
SF
C~
6C
30
100
SF
30
1C
~S
F3
04
C
1.0
.4
TJ = 25
Pulse Width=300us
1% Duty Cycle
50
TJ = 25
5C
~S
F3
07
C
25
0
.1
.1
.4
.6
.8
1.0
1.2
1.4
1.6
1.8
INSTANTANEOUS FORWARD VOLTAGE, (V)
.5 1.0 2
5 10 20
50 100 200
REVERSE VOLTAGE, ( V )
2. Marking on the body
Plant - code
Rectron Logo
Part No.
V X
X
X
Year – code
Y: Last digit of year &
A:2010,B:2011……)
Week – code
(WW:01~52)
Voltage-code
1-------50V
2-------100V
3-------150V
4-------200V
5-------300V
6-------400V
7-------600V
S F3 0 XC
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
TUBE PACK
PACKAGE
TO-220
PACKING CODE
-C
EA PER BOX
1,000
INNER BOX SIZE
(mm)
555*150*40
CARTON SIZE
(mm)
580*230*175
EA PER CARTON
5,000
WEIGHT(Kg)
15.0
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi-
lity for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" paramet-
ers which may be included on RECTRON data sheets and/ or specifications ca-
n and do vary in different applications and actual performance may vary over ti-
me. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other rela-
ted applications where a failure or malfunction of component or circuitry may di-
rectly or indirectly cause injury or threaten a life without expressed written appr-
oval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rect-
ron Inc and its subsidiaries harmless against all claims, damages and expendit-
ures.