40 WATTS OUTPUT POWER
•
2:1 WIDE INPUT VOLTAGE RANGE
•
DESIGN MEET SAFETY STANDARD
•
SIX-SIDED CONTINUOUS SHIELD
•
HIGH EFFICIENCY UP TO 90%
•
STANDARD 3” X 2.6” X 0.4” PACKAGE
•
FIXED SWITCHING FREQUENCY
The FDC40 series offer 40 Watts of output power from a 3 x 2.6 x 0.4 inch package.
The FDC40 series have 2:1 wide input voltage of 9-18, 18-36 and 36-75VDC. The FDC40
features 1600VDC of isolation, short-circuit and over-voltage protection, as well as six
sided shielding. Designed meets the safety of EN60950 and UL1950. All models are
particularly suited to telecommunications, industrial, mobile telecom and test equipment
applications.
Patent No. 460344
T E C H N I C A L S P E C I F I C AT I O N
OUTPUT SPECIFICATIONS
Output power
Single & Dual
Voltage accuracy Full load and nominal Vin Triple 3.3V/5V
Auxiliary
Voltage adjustability
FDC40-XXD3305 3.3V output
Minimum load (Note 1)
Others
Single
Dual
Line regulation
LL to HL at Full Load
Triple 3.3V/5V
Auxiliary
Single
Dual
Load regulation 10% to 100% FL
Triple 3.3V/5V
Auxiliary
Dual
Cross regulation (Note 2)
Triple 3.3V/5V
Auxiliary
Ripple and noise
Temperature coefficient
Transient response recovery time 25% load step change
3.3V output
Over voltage protection 5V output
Zener diode clamp
12V output
15V output
Short circuit protection
20MHz bandwidth
All specifications are typical at nominal input, full load and 25ºC otherwise noted
GENERAL SPECIFICATIONS
40 Watts max
± 2%
± 2%
± 5%
± 10%
20% min
10% of FL
± 0.5%
± 1%
± 2%
± 5%
± 0.5%
± 1%
± 2%
± 5%
± 1%
± 1%
± 5%
Efficiency
Isolation voltage
Isolation resistance
Isolation capacitance
Switching frequency
Design meet safety standard
Case material
Base material
Potting material
Dimensions
Weight
MTBF (Note 5)
9
See table
1600VDC, min
10 ohms, min
500Pf, max
185KHz, typ
UL1950, EN60950
Nickel-coated copper
Non-conductive black FR4
Epoxy (UL94-V0)
3.00 X 2.60 X 0.40 Inch
(70.2 X 66.0 X 10.2 mm)
125g (4.4oz)
1.590 x 10
6
hrs
1%/p-p of Vout max
I0.02%
/ ºC, max
500uS
3.9V
6.2V
15V
18V
Hiccup, automatics recovery
ENVIRONMENTAL SPECIFICATIONS
Operating temperature range
Maximum case temperature
Storage temperature range
Thermal impedance
Thermal shock
Vibration
Nature convection
-40ºC ~ +85ºC (with derating)
+100ºC
-55ºC ~ +105ºC
5.7ºC/watt
MIL-STD-810D
10~55Hz, 2G, 30minitues along X,Y and Z
5% to 95% RH
INPUT SPECIFICATIONS
Input voltage range
Input filter
12V input
24V input
48V input
Input reflected ripple (Note 3) Nominal Vin and full load
Input surge voltage
100mS max
Start up time
Nominal Vin and constant resistor load
DC-DC ON
DC-DC OFF
Nominal input
Remote ON/OFF
(Note 4)
Remote off input current
12V nominal input
24V nominal input
48V nominal input
9 – 18VDC
18 – 36VDC
36 – 75VDC
Pi type
36VDC
50VDC
100VDC
40mAp-p
25mS typ
Relative humidity
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
Conducted immunity
Radiated immunity
Surge
Fast transient
ESD
EN55022
EN55022
EN61000-4-6
EN61000-4-3
EN61000-4-5
EN61000-4-4
EN61000-4-2
Level A
Level A
Perf. Criteria2
Perf. Criteria2
Perf. Criteria2
Perf. Criteria2
Perf. Criteria2
Open or 3.5V < Vr < 12V
Short or 0V < Vr < 1.2V
30mA
Model
Number
FDC40-12S33
FDC40-12S05
FDC40-12S12
FDC40-12S15
FDC40-12D05
FDC40-12D12
FDC40-12D15
FDC40-12D3305
FDC40-12T0512
FDC40-12T0515
FDC40-24S33
FDC40-24S05
FDC40-24S12
FDC40-24S15
FDC40-24D05
FDC40-24D12
FDC40-24D15
FDC40-24D3305
FDC40-24T0512
FDC40-24T0515
FDC40-48S33
FDC40-48S05
FDC40-48S12
FDC40-48S15
FDC40-48D05
FDC40-48D12
FDC40-48D15
FDC40-48D3305
FDC40-48T0512
FDC40-48T0515
Input
Range
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
9 – 18 VDC
18 – 36 VDC
18 – 36 VDC
18 – 36 VDC
18 – 36 VDC
18 – 36 VDC
18 – 36 VDC
18 – 36 VDC
18 – 36 VDC
18 – 36 VDC
18 – 36 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
Output
Voltage
3.3 VDC
5 VDC
12 VDC
15 VDC
± 5 VDC
± 12 VDC
± 15 VDC
3.3 / 5VDC
5 / ± 12 VDC
5 / ± 15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
± 5 VDC
± 12 VDC
± 15 VDC
3.3 / 5VDC
5 / ± 12 VDC
5 / ± 15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
± 5 VDC
± 12 VDC
± 15 VDC
3.3 / 5VDC
5 / ± 12 VDC
5 / ± 15 VDC
Output
Current
10000mA
8000mA
3400mA
2700mA
+7000 / -1000mA
± 1800mA
± 1400mA
4000 / 4000mA
4000 / ± 850mA
4000 / ± 680mA
10000mA
8000mA
3400mA
2700mA
+7000 / -1000mA
± 1800mA
± 1400mA
4000 / 4000mA
4000 / ± 850mA
4000 / ± 680mA
10000mA
8000mA
3400mA
2700mA
+7000 / -1000mA
± 1800mA
± 1400mA
4000 / 4000mA
4000 / ± 850mA
4000 / ± 680mA
Input
(6)
Current
3530mA
4170mA
4100mA
4100mA
4330mA
4550mA
4430mA
3730mA
4490mA
4430mA
1720mA
2010mA
1980mA
2000mA
2130mA
2170mA
2140mA
1840mA
2180mA
2160mA
850mA
980mA
1000mA
1000mA
1060mA
1100mA
1100mA
910mA
1060mA
1060mA
Eff
(%)
83
84
87
87
81
83
83
78
79
80
84
87
90
88
82
87
86
79
81
82
85
89
89
88
84
86
86
80
83
83
(7)
Capacitor
Load max
(8)
25800uF
13600uF
2400uF
1550uF
12000 / 1700uF
± 1200uF
± 750uF
10300 / 6800uF
6800 / ± 590uF
6800 / ± 380uF
25800uF
13600uF
2400uF
1550uF
12000 / 1700uF
± 1200uF
± 750uF
10300 / 6800uF
6800 / ± 590uF
6800 / ± 380uF
25800uF
13600uF
2400uF
1550uF
12000 / 1700uF
± 1200uF
± 750uF
10300 / 6800uF
6800 / ± 590uF
6800 / ± 380uF
Note
1.
2.
The FDC40 series required a minimum 10% loading on the output to maintain
specified regulation. Operation under no-load condition will not damage these
devices, however they may not meet all listed specification.
Cross regulation:
Dual output—Asymmetrical load 25% to 100% full load
Triple output – 3.3V / 5V 100% load and one of auxiliary 100% load, other
auxiliary load change from 25% to 100% load
Simulated source impedance of 12uH. 12uH inductor in series with +Vin.
The ON-OFF control pin voltage is reference to negative input.
BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40ºC.
(Ground fixed and controlled environment)
Maximum value at nominal input voltage and full load
Typical value at nominal input voltage and full load
Test by minimum Vin and constant resistor load.
FDC40-48S05
Efficiency VS Input Voltage
EFFICIENCY (%)
90
89
88
87
86
85
84
83
82
81
80
36
40
45
50
55
60
65
70
75
3.
4.
5.
6.
7.
8.
INPUT VOLTAGE (V)
FDC40-48S05 Derating Curve
OUTPUT POWER (%)
EFFICIENCY (%)
FDC40-48S05
Efficiency VS Output load
90
89
88
86
84
82
80
70
60
50
45
0.5
100
75
50
25
0
-40 -25 -10
Nature convection
0
50
60
70
80
90
100
1
2
3
4
5
6
7
8
AMBIENT TEMPERATURE (ºC)
OUTPUT LOAD (A)
0.30 (7.6)
2.60 (66.0)
0.40
0.60 (15.2) (10.2)
0.40
(10.2)
0.70 (17.8)
0.40
(10.2)
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed by
using the method shown below.
( ) for dual output trim
[ ] for triple output trim
{ } XXD3305 only trim 3.3V/5V
TRIM UP
TRIM DOWN
DIA. 0.04 (1.0)
1
2
3
4
7 (7) [9] {6}
6 (8) [10] {8}
R
U
6 (8) [10] {8}
5 (5) [8] {5}
R
D
3.00 (76.2)
2.50 (63.5)
Bottom
View
PIN CONNECTION
PIN
SINGLE
CTRL
+ INPUT
- INPUT
SYNC
TRIM DOWN
TRIM
TRIM UP
+ OUTPUT
- OUTPUT
NO PIN
DUAL
CTRL
+ INPUT
- INPUT
SYNC
+ OUTPUT
COMMON
- OUTPUT
TRIM
NC
NC
TRIPLE
CTRL
+ INPUT
- INPUT
SYNC
+ AUX
COMMON (AUX)
- AUX
+ OUTPUT(PRIMARY)
COMMON(PRIMARY)
3.3V / 5V
CTRL
+ INPUT
- INPUT
SYNC
+3.3V
COMMON
+ 5V
TRIM
NC
NC
5
6
7
0.50
(12.7)
8
9
10
0.32
(8.0)
0.30 (7.6)
0.30 (7.6)
0.40
0.40
0.40
(10.2) (10.2) (10.2)
1. All dimensions in Inches (mm)
2. Pin pitch tolerance
I0.014(0.35)
1
2
3
4
5
6
7
8
9
10
TRIM
Converter 1
+ Vin
2
4
3
+
Sync
Application of synchronization
1. The unit is capable of external synchronization from an
independent time base with a switching rate between 200kHz
and 215kHz
2. The amplitude of the synchronizing pulse train is TTL
compatible
3. The duty cycle of the CLK should be 20% high and 80% low
4. Synchronization is referenced to negative input (-Vin)
- Vin
-
Converter 2
2
4
3
+
Sync
ON/OFF Control application
-
+ Vin
Converter
2
1
CLK
CLK Signal
80%
2N7000
+
CTRL
- Vin
ON/OFF Control
3
-
20%