XS8G12PA140L1
inductive sensor XS8 12x40x26 - plastic -
Sn4mm - 12..24VDC - cable 5m
Main
Range of product
Series name
Sensor type
Product specific appli-
cation
Sensor name
Sensor design
Size
Body type
Enclosure material
Type of output signal
Wiring technique
[Sn] nominal sensing
distance
Discrete output function
Discrete output type
Electrical connection
Cable length
Wire insulation material
[Us] rated supply volt-
age
Switching capacity in
mA
IP degree of protection
OsiSense XS
General purpose
Inductive proximity sensor
-
XS8
Form 12 x 40 x 26
26 mm
Fixed
Plastic
3-wire
4 mm
1 NO
PNP
Cable
5m
PVC
12...24 V DC
≤ 100 mA with overload and short-circuit protection
IP67 conforming to IEC 60529
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Discrete
Complementary
Detection face
Detector flush mounting acceptance
Material
[Sd] sensing range
Operating zone
Differential travel
Repeat accuracy
Output circuit type
Cable composition
Status LED
Supply voltage limits
Switching frequency
Voltage drop
Current consumption
Delay first up
Delay response
Delay recovery
Marking
Length
Lateral
Non flush mountable
Plastic
> 2.5...4 mm
0...3.2 mm
3...20% of Sr
<= 10% of Sr
DC
3 x 0.34 mm²
1 LED yellow for output state
10...30 V DC
<= 1000 Hz
≤ 1.8 V at closed state
0...10 mA at no-load
≤ 4 ms
≤ 0.5 ms
≤ 1 ms
CE
40 mm
Feb 19, 2018
1
Environment
Product certifications
Ambient air temperature for operation
Ambient air temperature for storage
Vibration resistance
Shock resistance
RoHS EUR conformity date
RoHS EUR status
CSA
UL
-25...70 °C
-40...85 °C
25 gn amplitude = +/- 2 mm (f = 10...55 Hz) conforming to IEC 60068-2-6
50 gn for 11 ms conforming to IEC 60068-2-27
0836
Compliant
2