Fuseholder Blocks & Clips
https://www.schurter.com /PG02
OGD-SMD
Fuseholder Open Design, 5 x 20 / 6.3 x 32 mm, SMD, VDE: 250/500 VAC, UL/CSA: 600 V, Cover, IEC
60355-1
250/500 VAC · 4 W / 10 A (VDE) · 600 V · 16 A (UL/CSA)
Description
See below:
Approvals and Compliances
Applications
References
- Equipment with three-phase supply (400 VAC)
Packaging Details
Phase-Out: 0031.8241.F1, 0031.8242.F1
Last order possibility: 30.09.2017
Last delivery date: 31.12.2017
- Fuseholder for 500 VAC (according to IEC) or 600 V (according to UL /
CSA) applications
- Suitable for use in devices according to IEC 60335-1 Ed. 4.0 for appli-
ances in unattended use (clause 30.2.3). This includes the enhanced
requirements of glow wire tests acc. to IEC 60695-2-12 and -13. Or-
der number: 0031.8242 or 0031.8242.F1
- Fuse block accepts 5x20 or 6.3x32 fuse-links
Weblinks
pdf datasheet, html-datasheet, General Product Information, Packaging
details, Distributor-Stock-Check, Accessories, Detailed request for
product, Microsite
Technical Data
Shock-Safe Category
Fuse-Link
Mounting
Attachment
Terminal
Rated Voltage
Rated current
Rated Power Acceptance IEC
PC1
5 x 20 or 6.3 x 32 mm
PCB
Screw or Rivet
Solder SMT
250/500 VAC (VDE), 600 V (UL/CSA)
10 A (VDE), 16 A (UL/CSA)
4 W / 10 A @ Ta 23 °C
2.5 W / 10 A with transparant cover
Degree of Protection
IP 20 (with cover)
Protection Class
Suitable for appliances with protection
class I acc. to IEC 61140
Admissible Ambient Air Temp. -40 °C to 85 °C
Climatic Category
40/085/21 acc. to IEC 60068-1
Material: Socket
Thermoplastic, black, UL 94V-0
Material: Cover
Thermoplastic black UL 94V-0
Material: Terminals
Tin-Plated Copper Alloy
Unit Weight
3.7 g
Storage Conditions
0 °C to 60 °C, max. 70% r.h.
Product Marking
, Type, Rated Voltage, Power Acc./
Current Rating, Approvals
Soldering Methods
Solderability
Contact Resistance
Dielectric Strength
Impulse Withstand Voltage
Insulation Resistance
Overvoltage Category
Pollution Degree
Reflow (lead-free)
Soldering Profile
245-260 °C / max. 30 sec acc. to JE-
DEC J-STD-020D
< 5 mΩ at 20 mV
> 3 kV
(50 Hz; 1 min)
> 6 kV between life parts
> 10 MΩ between life parts
(500 VDC; 1 min)
III acc. to IEC 60664-1
3 acc. to IEC 60664-1
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
Fuses
1
OGD-SMD
Approvals
Fuseholder Blocks & Clips
https://www.schurter.com /PG02
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: OGD-SMD
Approval Logo
Certificates
VDE Approvals
VDE Approvals
UL Approvals
Certification Body
VDE
VDE
UL
Description
VDE Certificate Number: 40008993
VDE Certificate Number: 40018378
UL File Number: E39328
Product standards
Product standards that are referenced
Organization
Design
Designed according to
Designed according to
Designed according to
Standard
IEC 60127-6
UL 4248-1
CSA C22.2 no. 4248.1
Description
Miniature fuses. Part 6. Fuse-holders for miniature fuse-links
Fuseholder general requirements
Fuseholder general requirements
Application standards
Application standards where the product can be used
Organization
Design
Designed for applications acc.
Designed for applications acc.
Standard
IEC/UL 60950
IEC 60335-1
Description
IEC 60950-1 includes the basic requirements for the safety of information
technologyequipment.
Safety of electrical appliances for household and similar purposes. Meets
the requirements for appliances in unattended use. This includes the en-
hanced requirements of glow wire tests acc. to IEC 60695-2-12 and -13.
Compliances
The product complies with following Guide Lines
Identification
Details
CE declaration of conformity
Initiator
SCHURTER AG
Description
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
EU Directive RoHS 2011/65/EU
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
Meets the glow wire test acc. IEC 60335-1 edition 4
RoHS
China RoHS
REACH
SCHURTER AG
SCHURTER AG
SCHURTER AG
White paperGlow wire test
SCHURTER AG
Dimension [mm]
35.4 mm
ø 4.8
13.4
12.7
0.7
12
16
4
1.1
20
ø 2.7
9.7
10.9
4.6
35.4
Solder pads
2
Fuses
Fuseholder Blocks & Clips
https://www.schurter.com /PG02
OGD-SMD
Derating Curves
Admissible Power Acceptance in Watt
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
0
20
40
60
80
100
I = 1.0 I
n
I = 0.7 I
n
I = << I
n
Ambient Air Temperature T
a
°C
All Variants
Holder
l
l
l
l
Material
Thermoplastic
Thermoplastic
Spec. Thermoplastic 2
Spec. Thermoplastic 2
Reflow Condition
acc. to JEDEC J-STD-020D, Tp=245 +0/-5 °C, tp = max. 30 s
acc. to JEDEC J-STD-020D, Tp=245 +0/-5 °C, tp = max. 30 s
acc. to JEDEC J-STD-020D, Tp=260 +0/-5 °C, tp = max. 30 s
acc. to JEDEC J-STD-020D, Tp=260 +0/-5 °C, tp = max. 30 s
Remark
-
-
-
-
Order Number
0031.8241
0031.8241.F1
0031.8242
0031.8242.F1
█
█
Most Popular.
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
Spec. thermoplastic is suitable for use in devices according to IEC 60335-1 for appliances in unattended use (clause 30.2.3). This standard
includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-12 and -13.
Packaging Unit
xxxx.xxxx
xxxx.xxxx.F1
Bulk 178 x 91 x 71 mm (100 pcs.)
Bar Packaging (20x50 pcs.)
Accessories
Description
Cover for OGD, OGD-SMD
Cover for Holder OGD, OGD-SMD
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
Fuses
3
26.02.2018