Features
■
Size: 8 mm diameter, 8 mm length
■
Axial leaded device
■
High voltage range up to 6 kV
■
High insulation resistance
■
RoHS compliant*
■
Applications
■
Industrial equipment/electronics
■
Telecommunications electronics
■
Consumer electronics
*R
oH
S
CO
M
UL Recognized
2095 Series
High Voltage 2-Electrode Gas Discharge Tube
Characteristics
Test Methods per ITU-T (CCITT) K.12 and IEC 61643-311.
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
Characteristic
DC Sparkover ±20 % @ 100 V/s
Impulse Sparkover
100 V/µs
1000 V/µs
2095-80
800 V
< 1100 V
< 1200 V
2095-100
1000 V
< 1300 V
< 1400 V
Model No.
2095-140
1400 V
< 2100 V
< 2200 V
Model No.
2095-300
3000 V
< 4100 V
< 4200 V
2095-160
1600 V
< 2300 V
< 2400 V
2095-200
2000 V
< 2700 V
< 2800 V
2095-250
2500 V
< 3500 V
< 3600 V
2095-270
2700 V
< 3600 V
< 3800 V
Model No.
2095-500
5000 V
< 6000 V
< 6400 V
2095-350
3500 V
< 4900 V
< 5000 V
2095-400
4000 V
< 5300 V
< 5500 V
2095-450
4500 V
< 5800 V
< 6000 V
2095-600
6000 V
< 7000 V
< 7800 V
Insulation Resistance (IR)
1
............................. 250/500/1000 Vdc.............................................> 1 GΩ
Glow Voltage ................................................... 10 mA................................................................~ 60 V
Arc Voltage ...................................................... 1 A .....................................................................~ 15 V
Capacitance..................................................... 1 MHz ...............................................................< 1.5 pF
Impulse Discharge Current
2095-80 through 2095-250 ......................... 8,000 A, 8/20 µs ................................................ 1 operation
5,000 A, 8/20 µs ................................................ 10 operations
2095-270 through 2095-600 ....................... 5,000 A, 8/20 µs ................................................ 1 operation
3,000 A, 8/20 µs ................................................ 10 operations
Alternating Discharge Current
2095-80 through 2095-250 ......................... 2 Arms, 50 Hz, 1 second ................................... 1 operation min.
10 Arms, 50 Hz, 9 cycles .................................. 1 operation min.
2095-270 through 2095-300 ....................... 3 Arms, 50 Hz, 1 second ................................... 1 operation min.
5 Arms, 50 Hz, 9 cycles .................................... 1 operation min.
2095-350 through 2095-600
2.5 Arms, 50 Hz, 1 second................................ 1 operation min.
5 Arms, 50 Hz, 9 cycles .................................... 1 operation min.
Impulse Life ..................................................... 100 A, 10/1000 µs .............................................> 100 operations
2
Operating Temperature............................................................................................................... -30 to +85 °C
Storage Temperature .................................................................................................................. -40 to +115 °C
Climatic Category (IEC 60068-1)................................................................................................ 40 / 90 / 21
Notes:
• UL Recognized component: UL File E135337.
• At delivery AQL 0.65 Level II, DIN ISO 2859.
Note 1:
DC Breakdown
IR Measuring Voltage
800-1000 V ..............................250 V
1400-2000 V ............................500 V
2500-6000 V ............................1000 V
Model 2095-270 and 2095-300 meet >300 operations at 100 A, 10/1000 µs.
Note 2:
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
2095 Series
High Voltage 2-Electrode Gas Discharge Tube
Product Dimensions
20
(0.78)
LONG
2 PLCS.
2095-xxx-B
2095-xxx-C
0.8 ± 0.05
1.0 ± 0.05
(.031 ± .002) OR (.039 ± .002)
DIA.
DIA.
MIN.
8.0 +0.3/-0.5
(.315 + .012/-.020)
DIA.
MODELS
2095-80 THRU 2095-450
8.0 +0.6/-0.1
(.315 +.024/-.004)
OR
MODELS
2095-500 & 2095-600
10.0 +0.6/-0.1
(.394 +.024/-.004)
MODELS
2095-80
THRU 2095-450
MODELS
2095-500
& 2095-600
DIMENSIONS:
MM
(INCHES)
Packaging Specifications
Model 2095 ships standard bulk, 100 pcs. per tray; 5 trays per box (500 units). The optional reelpack (-BT1) contains 500 pcs. per reel;
2 reels per box (1K units).
MODELS
2095-80 THRU 2095-450
8.0 + 1.4
(.315 + .055)
MAX.
OR
MODELS
2095-500 & 2095-600
10.0 + 1.4
(.394 + .055)
MAX.
330 ± 4.0
(12.992 ± .157)
DIA.
1.5
(.059)
TYP.
10.0 ± 0.5
(.394 ± .020)
100.0
(3.937)
TYP.
52 ± 2
(2.047 ± .079)
64 ± 3
(2.520 ± .118)
DIMENSIONS:
MM
(INCHES)
68.0
TYP.
(2.677)
How to Order
2095 - xxx - B T1 LF
Model Number Designator
Voltage (Divided by 10)
80 = 800 V
250 = 2500 V
100 = 1000 V
270 = 2700 V
140 = 1400 V
300 = 3000 V
160 = 1600 V
350 = 3500 V
200 = 2000 V
400 = 4000 V
450 = 4500 V
500 = 5000 V
600 = 6000 V
Leads
B = 0.8 mm (Available only for Models 2095-80 thru 2095-450)
C = 1.0 mm (Available only for Models 2095-500 & 2095-600)
Packaging
(Blank) = Bulk Packaging (Standard)
T1 = Reelpack (Optional)
RoHS Compliancy
LF = RoHS Compliant Product
Asia-Pacific:
Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116
Europe:
Tel: +41-41 768 5555 • Fax: +41-41 768 5510
The Americas:
Tel: +1-951 781-5500 • Fax: +1-951 781-5700
www.bourns.com
REV. A 04/12
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.