P.1
For Reference
Number: G6A-0903024B
Date of Issue: Nov.10.2011
OMRON Corporation
OMRON Relay & Devices Corporation
Prepared by
Checked by
Authorized by
Y.SUGA
T.ASO
T.MATSUSHITA
Name: MINI RELAY
Model: G6A-2-H
Item: DC ALL
Registration part number for Customer
Type name:
Type number:
Receipt Stamp(For receipt purpose only)
Handled by
Please accept handling of this specification sheet as for
reference use if no reply received.
Distribution
Copy
Customer
Revision Record
Mark Date
Contents
Sales(
)
DP-720101-2C
Spec No:G6A-0903024B
P. 2
1.Classification
2.Construction
2.1 Outline dimensions
2.2
2.3
2.4
2.5
2.6
Structure drawing
Contact configuration
Contact structure
Contact material
Protective construction
Single stable relay
Drawing No.2479484-3
Drawing No.--------
DPDT (2c contact)
Twin crossbar contact
Face material
Base material
Plastic sealed
UL
CSA
FCC
See table1
Resistive load 125VAC 0.5A
30VDC 2A
A½ Alloy
A½
3.Standards
3.1 Approved by standard(s)
File No.
File No.
P½½½68
:E41515
:LR31928
3.2
Others
4.Ratings
4.1 Coil ratings
4.2 Contact ratings
(1) Rated load
(2)
(3)
(4)
(5)
(6)
Inductive load 125VAC 0.3A
(½.½.=0.4)
30VDC 1A
(L/R=7ms)
Rated carry current
3A
Maximum rated voltage 250 VAC 220VDC
Maximum rated current
Resistive load AC2A DC2A
Inductive load AC1A
(½.½.=0.4)
DC1A
(L/R=7ms)
Maximum switching capacity
Resistive load AC125VA DC60W
Inductive load AC62.5VA
(½.½.=0.4)
DC30W
(L/R=7ms)
Failure rate(reference value)
DC10½V 10μA
(P level)( λ =0.1×10 /ops.)
5.Characteristics(initial value)
5.1 Contact resistance
50 ½Ω MAX.
Measured by the voltage drop method with
DC1V 10½A applied
5.2 Must operate voltage(or set voltage)
See table 1
5.3 Must release voltage(or reset voltage) See table 1
5.4 Operate time (or set time) 5 ms MAX.(at rated voltage)
5.5 Release time (or reset time)3 ms MAX.(at rated voltage)
5.6 Minimum input pulse width
--- ms
(Applicable to latching relay only, at rated voltage)
Spec No:G6A-0903024B
P. 3
5.7 Insulation resistance 500VDC
(1)Between coil terminals and contact terminals
1000 MΩ MIN.
(2)Between non-continuous current-carrying contact terminals
1000 MΩ MIN.
(3)Between contact terminals of the same polarity
1000 MΩ MIN.
(4)Between set coil and reset coil
---- MΩ MIN.
(5)Between current-carrying terminal and exposed non-current currying
metal part.
---- MΩ MIN.
5.8 Dielectric strength(leakage current1mA 50/60Hz for a minute)
(1)Between coil terminals and contact terminals
AC1000 V
(2)Between non-continuous current-carrying terminals
AC1000 V
(3)Between contact terminals of the same polarity
AC750 V
(4)Between set coil and reset coil
AC---- V
(5)Between current-carrying terminal and exposed non-current carrying
metal part.
AC---- V
5.9 Temperature rise
(1) Coil
65℃ MAX.
(by the coil resistance method)at.---℃
Applied voltage of coil:100%
of rated voltage---Hz
Carry current of contact3A
65℃ MAX.
(by the thermometer method)at.---℃
Applied voltage of coil:100%
of rated voltage ---Hz
Carry current of contact3A
Must be free from any abnormality in both
the construction and characteristics after the
relay is subjected to a variable vibration of
2.5mm single amplitude(5mm double amplitude)
at a vibration frequency of 10-55-10 Hz
in each direction for 2 hours.
Contacts must not open for 1ms
or longer after the relay is subjected to a
variable vibration of 1.65mm single amplitude
(3.3mm double amplitude) at a vibration frequency
of 10-55-10 Hz in each direction for 1 cycle.
(2) Contact
5.10 Vibration
(1) Mechanical durability
(2) Malfunction durability
(When energized)
or set status
(When not energized) Contacts must not open for 1ms
or reset status
or longer after the relay is subjected to a
variable vibration of 1.65mm single amplitude
(3.3mm double amplitude) at a vibration frequency
of 10-55-10 Hz in each direction for 1 cycle.
5.11 Shock
(1)Mechanical durability
Must be free from any abnormality in both
the construction and characteristics after the
relay is subjected to a shock of 1000m/s
in each direction 3 times.
Spec No:G6A-0903024B
P. 4
(2)Malfunction durability
(When energized)
or set status
(When not energized)
or reset status
Contacts must not open for1ms
or longer after the relay is subjected to a
shock of 500 m/s in each direction
3times.
Contacts must not open for1ms or
longer after the relay is subjected to a shock
of 500m/s in each direction
3times.
Must be free from any abnormality after
a tensile stress of 4.9N is applied to the
terminal in any direction vertical to the
terminal tip for 10 seconds.
Any deformation of the terminal by the load
shall not be regard as a mechanical damage.
Must be free from any abnormality in both the
construction and characteristics after the
relay is left in a temperature of 85±2℃
for 16 hours and then in room temperature and
humidity for 2 hours.
Must be free from any abnormality in both the
construction and characteristics after the
relay is left in a temperature of -55±3 ℃
for 72 hours and then in room temperature and
humidity for 2 hours.
Must be free from any abnormality in both the
construction and characteristics after the
relay is left in a humidity of 90 to 95% RH
for 48 hours at a temperature of 40±2℃, and
then in room temperature and humidity for
2 hours.
Insulation resistance, however,
must be 5 MΩ MIN.
The product shall be free from any abnormality
in both the construction and characteristics
after the terminals are dipped into molten
solder at 260±5℃ for 10 seconds and
then left in room temperature and humidity for
2 hours or after mounted by the recommended
condition of temperature profiles shown in
item ---.
100,000,000 operations MIN.
(under no load at operating frequency of
36,000 operations/hour)
100,000 operations MIN.
(under rated load, at operating frequency of
1,800 operations/hour)
5.12 Terminal strength
5.13 Temperature resistance
(1) Heat resistance
(2) Cold resistance
5.14 Moisture resistance
5.15 Soldering heat
5.16 Endurance
(1)Mechanical endurance
(2)Electrical endurance
※Unless otherwise specified, the above mentioned item 4 (Ratings) and
5 (Characteristics) values are under the standard conditions of
Ambient temperature 23℃ and Humidity 65%RH.
Spec No:G6A-0903024B
P. 5
6.Storage conditions
(1) Store in locations in normal temperature,humidity and atmosphere
pressure.
(2) Environments
½Store in locations where the product or container is not exposed to
corrosive gas such as hydrogen sulfide gas or salty air.
½Store in locations where no visible dust exists.
½Store in locations where the product is not exposed to the direct ray
of the sun and rain, snow.
Also please do not apply the force to product which may result
in the deformation or a change in quality of the product.
7.Operating conditions
7.1 Ambient temperature
7.2 Relative humidity
7.3 Mounting direction
Use the product under the following conditions.
-40 to +70℃
(without freezing or condensation)
5 to 85 %RH
F½½½
7.4 Enviroments
(1) Use in locations where the product is not exposed to corrosive gas
such as hydrogen sulfide gas or salty air.
(2) Use in locations where no visible dust exists.
(3) Use in locations where the product is not exposed to the direct ray
of the sun and rain, snow.
Also please do not apply the force to product which may result
in the deformation or a change in quality of the product.
8.Others
8.1 Weight
8.2 Impulse
Between
Between
Between
Approx. 3.5g
withstand voltage
(at10×160μs)
coil and contact
1500V
non-continuous contact
----
continuous contact
----