Accessories
ZGGZ80 - Interconnection Strip
ZGGZ80-1
• Designed for the co-operation with plug-in sockets of miniature relays and with interface relays PI84 and PI85, which
are equipped with screw terminals; sockets and relays are mounted on 35 mm rail mount acc. to PN-EN 60715,
• Bridges common input signals (coil terminals A1 or A2) or output signals - see photo at the top,
• Maximum permissible current is 10 A / 250 V AC,
• Possibility of connection of 8 sockets or relays,
• Colors of strips: ZGGZ80-1 grey
ZGGZ80-1
Plug-in sockets
GZT 80
GZM 80
GZT 92
GZM 92
Relays for plugin sockets
RM84, RM85, RM87
RM84, RM85, RM87
RM84, RM85, RM87
RM84, RM85, RM87
Relays socket combination
PI84-…-M..G
(GZT80+RM84)
PI84-…-00L
(GZM80+RM84)
PI85-…-M..G
(GZT80+RM85)
PI85-…-00L
(GZM80+RM85)
Interface relay PI84 (PI85) is offered as a set: plug-in socket GZT80 or GZM80 + miniature relay RM84 (RM85) + signalling / protecting module type M... + retainer / retractor
clip GZT80-0040 + description plate GZT80-0035.
Altech Custom Assemblies
Dimensions
11.3
13.8
10
111.3 ± 0.2
1.5
15 15.8
3
15.8
15.8
15.8
15.8
15
Altech provides quick turnaround
and competitive prices on assemblies.
For complete assemblies contact Altech.
110
Altech Corp.
®
• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
DATA SUBJECT TO CHANGE WITHOUT NOTICE
Accessories
ZGGZ4 - Interconnection Strip
ZGGZ4-1
• Designed for the co-operation with plug-in sockets of miniature industrial relays and with interface relays PIR2,
PIR3 and PIR4, which are equipped with screw terminals; sockets and relays are mounted on 35 mm rail mount acc.
to PN-EN 60715,
• Bridges common input signals (coil terminals A1 or A2) or output signals - see photo at the top,
• Maximum permissible current is 10 A / 250 V AC,
• Possibility of connection of 6 sockets or relays,
• Colors of strips: ZGGZ4-1 grey
ZGGZ4-1
Plug-in sockets
GZT2
GZM2
GZT3
GZM3
GZT4
GZM4
Relays for plugin sockets
R2
R2
R3
R3
R4
R4
Relays socket combination
PIR2-…-00L (GZM2+R2)
PIR3-…-00L (GZM3+R3)
PIR4-…-00L (GZM4+R4)
Interface relay PIR2 (PIR3, PIR4) is offered as a set: plug-in socket GZM2 (GZM3, GZM4) + miniature industrial relay R2 (R3, R4) + signalling / protecting module type M... +
retainer / retractor clip GZT4-0040 + description plate GZT4-0035.
Altech Custom Assemblies
Dimensions
11.3
13.8
10
135.7 ± 0.2
1.5
26.2
3
27
27
27
26.2
Altech provides quick turnaround
and competitive prices on assemblies.
For complete assemblies contact Altech.
Altech Corp.
®
• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
DATA SUBJECT TO CHANGE WITHOUT NOTICE
111
Accessories
For Industrial Relays
Signalling / protecting module
type M...
Electromagnetic
relay
Removing the relay from the socket
with a retrainer / retractor clip.
Retainer / retractor clip
Description plate
Screw terminals
plug-in socket
Type of
plug-in socket
GZT80, GZT92
GZM80, GZM92
GZT2, GZT3, GZT4
GZM2, GZM3, GZM4
Retainer
/ retractor
clips
Type
Color
GZT80-0040
GZT4-0040
gray
gray
Description
plates
Type
color
For relays
Height of relay
GZT80-0035
GZT4-0035
white
RM84, RM85, RM87
15...16.5 mm
white
R2, R3, R4
35.6 mm
112
Altech Corp.
®
• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
DATA SUBJECT TO CHANGE WITHOUT NOTICE
Accessories
For Industrial Relays
For sockets type:
GZT80, GZT92, GZM80, GZM92, GZS80, GZS92,
ES 32, GZT2, GZT3, GZT4, GZM2, GZM3, GZM4
Modules are parallel connected with relay coil.
Polarity P: -A1/+A2. Polarity N: +A1/-A2.
Part Number
M21P
M21N
M31R
M32R
M33R
M31G*
M32G
M33G
M41G
M42G
M43G
M51
M52
M53
Color
Modules
Module D (polarization P)
It limits overvoltage on DC coils.
It limits overvoltage on DC coils.
Layout
Layout
6/230 V DC
6/230V DC
6/24 V DC
24/60 V DC
110/230V DC
6/24 V DC
24/60 V DC
110/230V DC
6/24 V DC
24/60V DC
110/230V DC
6/24V AC
24/60V AC
110/240V AC
Module D (polarization N)
red
red
red
green
green
green
green
green
green
Module LD (polarization P)
It limits overvoltage on DC coils.
Coil energizing indication.
Module LD (polarization N)
It limits overvoltage on DC coils.
Coil energizing indication.
Module RC
It protects against EMC disturbance.
It limits overvoltage.
M61R
M62R
M63R
M61G*
M62G
M63G*
M91R
M92R
M93R
M91G
M92G
M93G
M71
M72
M73
M103
red
red
red
green
green
green
red
red
red
green
green
green
Module L
Coil energizing indication.
6/24V AC/DC
24/60V AC/DC
110/230V AC/DC
6/24V AC/DC
24/60V AC/DC
110/230V AC/DC
6/24V AC/DC
24/60V AC/DC
110/230V AC/DC
6/24V AC/DC
24/60V AC/DC
110/230V AC/DC
24V AC
130V AC
230V AC
110/230V AC
Module LV
It limits overvoltage on AC and DC coils.
Coil energizing indication.
Module V
It limits overvoltage on AC and DC coils.
No indication.
Module R
It limits overvoltage on AC coils.
BOLD
-
Regular stocked items.
Altech Corp.
®
• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
DATA SUBJECT TO CHANGE WITHOUT NOTICE
113
Additional Features for Industrial Relays
Explantions for Additional Features
Type
W
Description
mechanical indicator
For industrial relays
R2, R3, R4,
R15 - DPDT, 3PDT
R2, R3, R4,
R15 - DPDT, 3PDT
T
lockable front test button,
orange colour - AC coils,
green colour - DC coils
light indicator (LED diode),
located inside the relay
L
R2, R3, R4, RY2,
R15 - DPDT, 3PDT, 4PDT
RUC, RUC-M
R2, R3, R4, RY2,
R15 - DPDT, 3PDT, 4PDT
R15 - DPDT, 3PDT
D
surge suppression element (diode)
- only for DC coils
surge suppression element (varistor)
- only for AC coils
test button without block function
V
K
R15 - 4PDT
RUC
WT
= mechanical indicator + lockable front test button; basic features of standard industrial relays: R2, R3, R4, R15
- DPDT, 3PDT - for plug-in sockets. Detailed information for individual relays: see ”Ordering codes - Additional features”.
Available combinations:
WT, WTL, WTD, WTLD - in relays R2, R3, R4 for plug-in sockets
L, D, LD - in relays RY2 for plug-in sockets
WT, WTL, WTD, WTLD, WTV, WTLV - in relays R15 - DPDT, 3PDT for plug-in sockets
K, L, D, KL, KD, LD, KLD - in relays R15 - 4PDT for plug-in sockets
K, L, KL - in relays RUC
L - in relays RUC-M
TEST BUTTONS
Type T
Orange
AC coils
Momentary test button.
Green
DC coils
114
Altech Corp.
®
• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
DATA SUBJECT TO CHANGE WITHOUT NOTICE